WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7150
Browse
Search Results
Now showing 1 - 2 of 2
Article Citation - WoS: 3Citation - Scopus: 4Microfluidic-Assisted Preparation of Nano and Microscale Chitosan Based 3d Composite Materials: Comparison With Conventional Methods(Wiley, 2022) Kimna, Ceren; Değer, Sibel; Tamburacı, Sedef; Tıhmınlıoğlu, FundaAlthough nanofillers contribute to improved physical characteristics and biological functionalities of polymer-based biomaterials, their dispersion in polymer matrices is still a challenging issue in terms of obtaining consistency for the inherent properties. To tackle this problem, homogenization techniques are applied to disperse the nanofillers in such polymers, however, these methods can cause undesired changes especially in the rheological properties and the physical structure of the biopolymer matrices. Recently, as a novel homogenization technique, microfluidization has been used to homogenize polymer nanocomposites to minimize these limitations. In this study, two different nanocomposite structures as chitosan/montmorillonite (CS/MMT) and chitosan/polyhedral oligomeric silsesquioxane nanocages (CS/POSS) were homogenized with microfluidization and investigated in terms of physical alterations. Furthermore, the effect of microfluidizer technique on material characteristics was compared with conventional homogenization techniques, i.e., ultrasonic bath and sonication in terms of solution, nano – (e.g., hydrodynamic size, drug encapsulation) and macroscopic material characteristics (e.g., porosity, mechanical properties, swelling and thermal degradation). It was found that the microfluidizer homogenization improves the physical characteristics in both nano and macroscale materials: Nanospheres obtained from CS/MMT composites showed enhanced stability, uniform size distribution (<100 nm, PDI: [removed]50%) whereas 3D porous CS/POSS scaffolds showed improved structural uniformity (i.e., homogeneous and interconnected microstructure) and enhanced thermal and mechanical properties. The obtained results indicate that the microfluidizer homogenization ensures a successful nanofiller dispersion in polymer matrices, thereby improving the biomaterial characteristics impressively compared to the sonication methods.Article Citation - WoS: 39Citation - Scopus: 41Effect of Post Fabrication Aging Treatment on the Microstructure, Crystallographic Texture and Elevated Temperature Mechanical Properties of In718 Alloy Fabricated by Selective Laser Melting(Elsevier, 2022) Özer, Seren; Bilgin, Güney Mert; Davut, Kemal; Esen, Ziya; Dericioğlu, Arcan.FThe effect of building direction and post fabrication aging treatment on the microstructure, crystallographic texture and high temperature mechanical properties of Inconel 718 (IN718) alloy fabricated by selective laser melting (SLM) method was investigated. After aging, arc-shaped structures seen in as-fabricated samples disappeared and converted into a mixture of columnar and equiaxed grains. Nano-sized γ″ and/or γ′ precipitates were formed upon aging; however, MC type carbides and Laves phase encountered in as-fabricated samples were not dissolved completely after aging. Moreover, aging did not alter the texture ((001)//building direction (BD)) of as-fabricated samples. Mechanical properties of the alloys under tension were influenced by the build direction, aging time and test temperature. As-fabricated samples produced in vertical direction exhibited higher room temperature strengths with lower ductility due to orientation of overlapped prior melt pools. Room temperature tensile test results revealed that peak aging caused a significant improvement in ultimate tensile strength (UTS), from 1066.5 MPa and 998.4 MPa to 1408.5 MPa and 1330.4 MPa whereas elongation values decreased from 27.5% and 32.2% to 19.6% and 23.7% in vertically and horizontally built samples, respectively. Peak-aged samples (aged at 700 °C for 8 h) tested at 600 °C displayed serrated regions in their stress-strain curves due to dynamic strain aging (DSA). Although strength values of the samples displayed an expected decrease by temperature, ductility of the samples reduced to minimum at temperatures around 700–800 °C, which was attributed to intermediate temperature embrittlement.
