WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7150

Browse

Search Results

Now showing 1 - 7 of 7
  • Article
    Citation - WoS: 4
    Citation - Scopus: 15
    Effects of Seismic Activity on Groundwater Level and Geothermal Systems in İzmir, Western Anatolia, Turkey: the Case Study From October 30, 2020 Samos Earthquake
    (TÜBİTAK - Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, 2021) Uzelli, Taygun; Bilgiç, Esra; Öztürk, Bahadır; Baba, Alper; Sözbilir, Hasan; Tatar, Orhan
    The October 30, 2020 Samos earthquake (Mw 6.6) affected the Aegean Sea and environs, caused destruction and loss of life in the city of İzmir located 70 km away from the earthquake epicenter. Before this earthquake, water resources were monitored in the areas of Bayraklı, Gülbahçe, and Seferihisar. For this purpose, 10 groundwater monitoring wells were drilled in the Bayraklı area, where groundwater level, temperature, and electrical conductivity changes were monitored at 1-h intervals in 5 wells. Besides physical parameters such as groundwater levels, temperatures and electrical conductivities, hydrogeochemical cations, and anions measured in the study area. Change in the groundwater levels was observed before, during, and after the Samos earthquake. A trend of rising groundwater level was observed two days before the mainshock, to a height of 10 cm, and the level was maintained till the end of the earthquake. The water levels returned to its original height after about 7 to 10 days of the earthquake. Moreover, electrical conductivity (EC) values were changed because of the interaction with the surrounding rocks and well walls, mixing with different waters during the earthquake shaking. The essential anomalies were observed in the geothermal fields of Gülbahçe and Seferihisar. Due to this earthquake, new geothermal springs emerged along the NE-SW trending Gülbahçe and Tuzla faults, located about 50 to 20 km from the Samos earthquake epicenter, respectively. The new geothermal waters are in Na-Cl composition and similar to other geothermal springs in the region. While the recorded water temperatures in the new geothermal springs vary from 40 to 45 °C in Seferihisar, it was measured between 35 and 40 °C in Gülbahçe. Due to these anomalies, it is found essential to monitor the effect of the earthquake on the physical and chemical characteristics of the groundwater and its usefulness in earthquake predictions.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 6
    Testing the Performance of Various Polymeric Antiscalants for Mitigation of Sb-Rich Precipitates Mimicking Stibnite-Based Geothermal Deposits
    (Hindawi Publishing Corporation, 2020) Çiftçi, Celal; Karaburun, Emre; Tonkul, Serhat; Baba, Alper; Demir, Mustafa Muammer; Yeşilnacar, Mehmet İrfan
    Scaling is frequently observed in geothermal fields and reduces the energy harvesting of power plants. Recently, Sb-rich deposits have developed in many fields around the world. Various polymeric macromolecules have been used as antiscalants to mitigate the formation of scale. Testing potential commercial antiscalants in field conditions is a tedious and costly process. The artificial synthesis of geothermal deposits in the lab is a more practical and economical way to test the performance of antiscalants. This study obtained a Sb-rich deposit by refluxing SbCl3 and Na2S center dot 3H(2)O in 18 h. The product was found to be a mixture of Sb2O3 and Sb2S3. We examined the performance of antiscalants such as poly(ethylene glycol), poly(vinyl pyrrolidone), Gelatin, and poly(vinyl alcohol) of various molecular weights at 5 to 100 ppm. The formation of Sb2S3 is suppressed in the presence of the polymeric antiscalants. The dosage was found to be critical for the solubilization of Sb-rich deposits. Gelatin of 5 ppm showed the highest performance under the conditions employed in this study. While low dosages improve the concentration of [Sb3+], high dosages are required to increase the solubility of [S2-]. Moreover, the amount of deposit is reduced by 12.4% compared to the reference (in the absence of any polymeric molecules). Thus, comparatively, Gelatin shows the most promising performance among the molecules employed.
  • Article
    Citation - WoS: 13
    Citation - Scopus: 16
    Experimental Modeling of Silicate-Based Geothermal Deposits
    (Elsevier Ltd., 2017) Çelik, Aslı; Topçu, Gökhan; Baba, Alper; Akdoğan, Yaşar; Şentürk, Ufuk; Demir, Mustafa Muammer
    Scaling by metal silicates represents a major obstacle for geothermal systems. A composition that enables the fabrication of artificial deposits is necessary for the rapid testing of potential inhibitors. In this work, artificial deposits were synthesized by employing experimental conditions similar to those in the Tuzla Geothermal Field in Turkey. Although refluxing enabled the formation of a precipitate that was similar to naturally formed deposits in color and texture, their elemental composition and morphology showed a mismatch. An autoclave enabled the production of a precipitate that more closely resembled naturally formed deposits in color, texture, elemental composition, and structure.
  • Article
    Citation - WoS: 83
    Citation - Scopus: 92
    Source of Arsenic Based on Geological and Hydrogeochemical Properties of Geothermal Systems in Western Turkey
    (Elsevier Ltd., 2012) Baba, Alper; Sözbilir, Hasan
    Turkey is an area of complex geology with active tectonics and high geothermal potential. Especially, the western part of Turkey is a region of abundant geothermal activity. Faults accommodating the deep circulation of hydrothermal fluids of meteoric origin are the primary means by which of geothermal systems are controlled in this region. Many of the thermal activities are related to the improved dilation on the ~E-W-strikes of the graben faults. This situation serves as a suitable environment for the presence of high levels of arsenic in geothermal water resources. The highest concentrations of naturally occurring aqueous arsenic (As) are found in certain types of geothermal waters, generally those related to major graben faults. In this regard, high arsenic concentrations in geothermal resources have been detected in Western Turkey, including but not limited to Biga Peninsulla, Gediz Graben, Kucuk, and Buyuk Menderes Graben with values ranging from 1 to 1419ppb in geothermal fluids. The thermal waters have surface temperatures of up to 100°C and reservoir temperatures range from 150 to 248°C in the Menderes Graben, from 120 to 287°C in the Gediz Graben, and from 153 to 174°C in Biga Peninsula. Hydrogeochemically, the Menderes graben and Gediz Graben thermal waters are of the Na-HCO3, Ca-HCO3, and Na-SO4 types, whereas some geothermal fluids such as those of Tuzla and Kestanbol in the Biga Peninsula, Çeşme, and Urla are of the Na-Cl type.
  • Article
    Citation - WoS: 5
    Citation - Scopus: 7
    Hydrogeochemistry and Environmental Properties of Geothermal Fields. Case Study: Balçova, Izmir-Turkey
    (Taylor and Francis Ltd., 2012) Çakın, Ayça; Gökçen Akkurt, Gülden; Eroğlu, Ahmet Emin; Baba, Alper
    Balcova Geothermal Field hosts the largest geothermal district heating system of Turkey and a number of shallow groundwater wells that are used for irrigation of the agricultural activities. The present study aims to assess the influence of geothermal fluid on groundwater by determining the hydrogeochemical properties of the water resources. A sampling program was conducted for 10 months and samples were collected from geothermal and groundwater wells including re-injected fluid. Trace and major elements, and the types of waters were determined. The results of groundwater analysis showed that the concentrations of some toxic species, such as arsenic, boron, and fluoride, exceeded the limits of drinking water standards set by TSE, EPA, and WHO.
  • Article
    Citation - WoS: 30
    Citation - Scopus: 36
    Hydrogeological Properties of Hyper-Saline Geothermal Brine and Application of Inhibiting Siliceous Scale Via Ph Modification
    (Elsevier Ltd., 2015) Baba, Alper; Demir, Mustafa Muammer; Koç, Gonca A.; Tuğcu, Celal
    Scaling is a major obstacle in harnessing of geothermal energy from the geothermal resources. This paper presents a case study for inhibition of metal silicate scaling using formic acid, harvesting more energy in particular case of Tuzla Geothermal Field (TGF), located on Biga Peninsula, in the northwestern of Turkey. TGF is 5. km far from Aegean Sea and 80. km south of Çanakkale. Geothermal fluid of TGF has high salinity (EC. > 91. mS/cm) and medium temperature (reservoir temperature is 173. °C). The acidification of high-salinity brine to mitigate silicate scaling is examined. Results of the study showed that a compromise between scaling and corrosion is achieved by reducing pH of brine to <6 using 55. ppm formic acid.
  • Article
    Citation - WoS: 35
    Citation - Scopus: 45
    Types of the Scaling in Hyper Saline Geothermal System in Northwest Turkey
    (Elsevier Ltd., 2014) Demir, Mustafa Muammer; Baba, Alper; Atilla, Vedat; İnanlı, Mustafa
    Tuzla is an active geothermal area located in northwestern Turkey, 80km south of the city of Canakkale and 5km from the Aegean Coast. The geothermal brine from this area, which is dominated by NaCl, has a typical temperature of 173°C. Rapid withdrawal of fluid to ambient surface conditions during sampling causes precipitation of various compounds known as scaling. Scaling is one of the important problems in Tuzla geothermal system that reduces the efficiency of the geothermal power plant and causes economical loss. The aim of this study was to determine the type of scaling as a first step towards preventing its formation. The scales formed in the geothermal system were divided into two groups according to location: the ones that formed in downhole and the ones that accumulated along the surface pipeline. Both scales were examined in terms of their elemental composition, structure and morphology using XRF, XRD, and SEM, respectively. The former was found to be mainly composed of PbS (Galena) and CaCO3 (aragonite or calcite). In contrast, the latter was heterogeneous in nature and consisted of mainly saponite like amorphous structure along with submicrometer-sized amorphous silica particles, layered double magnesium and iron hydroxide, and NaCl.