TR Dizin İndeksli Yayınlar / TR Dizin Indexed Publications Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7149
Browse
5 results
Search Results
Now showing 1 - 5 of 5
Article Design of Sulfur Resistant Cobalt Catalysts by Boron Promotion: Atomic Scale Insights(Sakarya University, 2024) Kizilkaya, A.C.The effect of boron promotion on atomic sulfur formation by hydrogen sulfide dissociation on Co(111), flat surfaces of cobalt nanoparticles, was investigated using Density Functional Theory calculations. The results show that on clean Co(111), hydrogen sulfide dissociation proceeds fast due to low activation barriers, yielding atomic sulfur on the cobalt surfaces. Boron promotion hinders the dissociation of hydrogen sulfide due to increased activation barriers. Furthermore, boron prevents the interaction of sulfur compounds with cobalt surface atoms, as these poisons bind on boron. The findings indicate that boron is an effective promoter that can be used to design sulfur resistant cobalt catalysts. © 2024, Sakarya University. All rights reserved.Article Occurrence of Bromide and Bromate in Chlorinated Indoor Swimming Pools, And Associated Health Risks(Yildiz Technical University, 2023) Dumanoğlu, Y.; Genisoglu, M.; Sofuoglu, S.C.Swimming is a physical activity that is accessible to people of all ages in all seasons. However, continuous organic and inorganic precursor load and disinfectant dosing make pool water chemistry much more complex than other disinfected waters. Carcinogenic bromate compound is one of the hundreds of disinfection by-products in pool water. The occurrence of bromate in pool waters depends on the precursor content of filling water, the disinfection process, operating parameters, and the purity of disinfectants. While the average filling water bromide concentrations of University Campus indoor swimming pool in Gülbahçe –Urla (SP1) and Buca public indoor swimming pool (SP2) were determined to be 182 μg/L and 11.0 μg/L, respectively, the average bromate concentrations of SP1 and SP2 were 59.4 μg/L and 68.3 μg/L. Estimated chronic-toxic health risks of accidental ingestion of pool water during swimming (between 10-3 and 10-1) were lower than the threshold level (‘1’). Although the carcinogenic risks in central tendency scenario (<10-6) indicate negligible risks for swimmers, worst case scenario indicates carcinogenic risks (medians were ranged from 1.61×10-6 to 9.42×10-6) for highly exposed specific swimmer groups. Bromate accumulation in swimming pools needs attention for mitigating the health risks for swimmers. © 2021, Yıldız Technical University.Article Investigation of Interactions of Acetylene Molecules With an Iron Nanowire and Its Effects on Mechanical Tensile Properties(Sakarya University, 2021) Aral, G.Understanding complex atomistic-scales interactions mechanisms of reactive acetylene (C2H2) molecules with reactive pure iron nanowires (Fe NWs) including its effects on the tensile mechanical properties of NWs is a crucial task in nanotechnology, especially having practical significance in the mechanical reliability, durability and stability. Therefore, we performed molecular dynamics (MD) simulations based on ReaxFF reactive force field interatomic potential model to investigate the interactions of C2H2 molecules with surface of cylindrical pure Fe NW and its fundamental effects on the tensile mechanical deformations properties of NWs at three different strain rates. Our results reveal that the chemical energetic reactions on the free surface of cylindrical Fe NW with C2H2 molecules in the gas phase form FexCyHz shell layer at temperature T=300 K. The presence of FexCyHz shell layer on the free surface of NW has a significant effect on the mechanical tensile deformation mechanism of the NWs. © 2021, Sakarya University. All rights reserved.Article Military Intelligence Deeds in the Reports of Izmir British Consulate General (1878-1914)(Ege Univ, 2011) Aditatar, FundaFrom 1825 up to the late nineteenth century the British Levant Consular Service developed highly parallel with the policy of Britain in the Ottoman Empire. During the protection policy of the Ottoman territory which continued until the 1870s, political and commercial aspects of consular services has been formulated almost an equal level. Instead of protecting the territorial integrity of the Empire after the Berlin Treaty of 1878 turned into a controlled sharing and consuls began press to served heavily political direction. The aim of this paper is to evaluate reports of Izmir British Consulate about military intelligence. The voluminous reports of the consulate related with the military intelligence. This situation occurs in Izmir because of commercial importance and strategic location, and also riots and wars all of these can be explained in the intensive military mobility during the last period of the Empire (1878-1914).Article Citation - WoS: 1Hydrogeochemical and Hydrogeological Investigation of the Can Geothermal Field(TMMOB Jeoloji Mühendisleri Odası, 2010) Deniz, Ozan; Baba, Alper; Tarcan, GultekinThe Can Geothermal Field is located on a central part of the Biga Peninsula in northwest Turkey. Volcanics are the dominant rock type in this region. Alteration zones and clay minerals are very common in these rocks. Sedimentary rocks, low-grade metamorphics and alluvium are other geological units observed around Can. These units include common fracture zones because of the tectonic activity in the region. Thermal waters have reached the surface via these fracture zones. Alluvium is the most productive aquifer in all geological units. Wells drilled in this unit yield between 5-30 L/s. The transmissibility and permeability coefficients of this unit are of 50-421 m(2)/day and of 1.01-16.8 m/day, respectively. In this aquifer, groundwater depth changes between 0.1 and 8.3m. According to the IAH (1979) water classification, these thermal waters are of the Na-Ca-SO4 type, the cold waters are of the Ca-Mg-HCO3 type and the snow samples are of a mixed water type. Geothermal waters have a meteoric origin. The mean temperature, electrical conductivity and pH of the thermal waters have values of 44.4 degrees C, 2941 mu S/cm and 6.9, respectively. Geothermometer equations were used for prediction of reservoir fluid temperatures of the geothermal system and temperature values were obtained between 46 and 203 degrees C. delta D, delta T and delta O-18 isotope analysis showes that thermal waters in the Can region have a meteoric origin and are a minimum of 45-50 years old.
