Chemical Engineering / Kimya Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/14
Browse
6 results
Search Results
Article Citation - WoS: 12Citation - Scopus: 12Supercritical Fluid Reactive Deposition: a Process Intensification Technique for Synthesis of Nanostructured Materials(Elsevier, 2022) Yousefzadeh, Hamed; Akgün, Işık Sena; Barım, Şansım Bengisu; Sarı, Tarık Bercan; Eriş, Gamze; Uzunlar, Erdal; Bozbağ, Selmi Erim; Erkey, CanSupercritical fluid reactive deposition (SFRD) is a promising process intensification technique for synthesis of a wide variety of nanostructured materials. The enhanced mass transfer characteristics of supercritical fluids (SCFs) coupled with high solubilities of reducing gases in SCFs provide many advantages related to equipment size and time minimization over conventional techniques. Among SCFs, the emphasis has been placed on supercritical CO2 (scCO2) which is non-toxic, cheap and leaves no residue on the treated medium. Moreover, in SFRD, multiple processes such as dissolution, adsorption, reaction, and purification are combined in a single piece of equipment which is an excellent example of process integration for process intensification. In this review, the fundamental thermodynamic and kinetic aspects of the technology are described in detail. The studies in the literature on synthesis of a wide variety of nanostructured materials including supported nanoparticles, films, and ion-exchanged zeolites by SFRD are reviewed and summarized. The applications of these materials as catalysts and sensors are described. The review hopes to lead to further studies on further development of this technology for a wide variety of applications.Article Citation - WoS: 23Citation - Scopus: 24Investigation of Kinetics of Supercritical Drying of Alginate Alcogel Particles(Elsevier Ltd., 2019) Şahin, İbrahim; Uzunlar, Erdal; Erkey, CanSpherical calcium alginate gel particles were synthesized by dripping method. The effects of temperature, pressure, particle size and CO2 flow rate on kinetics of supercritical drying of alginate gel particles in a packed bed were investigated. Increase in CO2 flow rate, increase in temperature and decrease in particle size increased the drying rate and decreased the drying time. A mathematical model based on (i) the diffusion of the solvent inside the pores of gel particles, (ii) external mass transfer of the solvent from the surface of the gel particles into the flowing fluid stream, and (iii) convection and axial dispersion of the solvent in the flowing fluid stream was developed. A correlation for predicting external mass transfer coefficients for supercritical drying of alcogel particles was developed by fitting the model to experimental data. A good agreement between the experimental data and model results was achieved using the developed correlation.Article Citation - Scopus: 5Effect of Isotherm Shape on Mass Transfer in an Adsorbent Particle; an Isothermal Adsorption Process(Bentham Science Publishers B.V., 2011) Yıldırım, Zeynep Elvan; Gediz İliş, Gamze; Mobedi, Moghtada; Ülkü, SemraThe mass diffusion equation and corresponding initial and boundary conditions were non-dimensionalized for a spherical adsorbent particle in an infinite adsorptive medium to reduce number of independent governing parameters into two as mass transfer Biot number and dimensionless isotherm. The changes in local and average adsorbate concentration throughout the adsorption process were calculated and plotted for different values of mass transfer Biot numbers (ranging from 0.5 to 750) and for five different isotherm shapes. The obtained results indicated that the isotherm shape influences dimensionless period of adsorption, if the external mass transfer resistance is significant in the process. For those cases, the total dimensionless adsorption period for a convex shape isotherm is shorter than a concave one.Article Citation - WoS: 9Citation - Scopus: 11Modeling of Hemodialysis Operation(Springer Verlag, 2010) Abacı, Hasan Erbil; Alsoy Altınkaya, SacideIn this study, a theoretical model was developed to predict the solute concentrations in patients' blood and optimize the efficiency of the hemodialysis operation. The model takes into account simultaneous mass and momentum transfer on the blood side both in radial and axial directions. A key component of the model is the incorporation of the protein adsorption on the inner surface of the membrane. The validity of the model was confirmed with the experimental data available in the literature for two different types of hemodiafilter. To illustrate the importance of including the radial concentration gradients and protein adsorption kinetics in the model, the experimental data were predicted with and without consideration of these effects. The results have shown that assuming uniform concentration in the radial direction or neglecting protein adsorption on the inner surface of the membrane leads to higher error in predicting the experimental data. In addition, significant error can be introduced in the calculation of the dialysis time if protein adsorption is not considered. © 2010 Biomedical Engineering Society.Article Citation - WoS: 2Citation - Scopus: 1Errors Associated With Swelling in the Analysis of Polymer-Solvent Diffusion Measurements(Elsevier Ltd., 2005) Alsoy Altınkaya, SacideSorption curves are generated from a mathematical model which includes the influence of the polymer swelling for unsteady-state sorption of a vapor or liquid by a polymer. To investigate the simultaneous effects of the specific volumes of the polymer-penetrant pair and the difference between the final and initial equilibrium concentrations on the sorption curves, statistical experimental design approach is used. Simulation results obtained from the numerical solution of model equations are utilized to estimate the error that would occur if one simply evaluates the diffusion coefficient using the traditional formulas derived from the analytical solution of the sorption equation. An empirical expression is developed that describes the effects of the difference between the final and initial equilibrium concentrations and the specific volumes of the polymer and the penetrant on the magnitude of error in diffusivity associated with the use of one of these traditional formulas so called the initial slope method. The predictive ability of the regression model is tested by performing additional simulations not used in the regression analysis.Article Citation - WoS: 24Citation - Scopus: 25Processing of Polymers With Supercritical Fluids(John Wiley and Sons Inc., 1999) Alsoy Altınkaya, Sacide; Duda, John LarryThe removal of impurities, such as residual solvents, unreacted monomers, catalysts, and side-reaction products from polymers represents an important step in polymer processing. Conventional devolatilization techniques for the purification of polymers have limited effectiveness. Devolatilization with supercritical fluids, however, can enhance impurity removal by increasing the thermodynamic driving force and molecular diffusivity.
