Chemical Engineering / Kimya Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/14

Browse

Search Results

Now showing 1 - 5 of 5
  • Article
    Citation - WoS: 10
    Citation - Scopus: 12
    Novel Hybrid Adsorption-Electrodialysis (aded) System for Removal of Boron From Geothermal Brine
    (American Chemical Society, 2022) Altınbaş, Bekir Fırat; Orak, Ceren; Ökten, Hatice Eser; Yüksel, Aslı
    A novel hybrid adsorption-electrodialysis (AdED) system to remove environmentally harmful boron from geothermal brine was designed and effective operating parameters such as pH, voltage, and flow rate were studied. A cellulose-based adsorbent was synthesized from glycidyl methacrylate (GMA) grafted cellulose and modified with a boron selective n-methyl-d-glucamine (NMDG) group and characterized with SEM-EDX, FT-IR, and TGA analyses. Batch adsorption studies revealed that cellulose-based adsorbent showed a remarkable boron removal capacity (19.29 mg/g), a wide stable operating pH range (2-10), and an adsorption process that followed the Freundlich isotherm (R2= 0.95) and pseudo-second-order kinetics (R2= 0.99). In the hybrid AdED system, the optimum operating parameters for boron removal were found to be a pH of 10, a voltage of 10 V, a flow rate of 100 mL/min, and an adsorbent dosage of 4 g/L. The presence of the adsorbent in the hybrid system increased boron removal from real geothermal brine (containing 199 ppm boron) from 7.2% to 73.3%. The results indicate that the designed AdED system performs better than bare electrodialysis for boron removal from ion-rich real geothermal brine while utilizing environmentally friendly cellulose-based adsorbent.
  • Article
    Citation - WoS: 31
    Citation - Scopus: 35
    Electrochemical Degradation of Methylene Blue by a Flexible Graphite Electrode: Techno-Economic Evaluation
    (American Chemical Society, 2022) Gören, Ayşegül Yağmur; Recepoğlu, Yaşar Kemal; Edebali, Özge; Şahin, Çağrı; Genişoğlu, Mesut; Ökten, Hatice Eser
    In this study, electrochemical removal of methylene blue (MB) from water using commercially available and low-cost flexible graphite was investigated. The operating conditions such as initial dye concentration, initial solution pH, electrolyte dose, electrical potential, and operating time were investigated. The Box-Behnken experimental design (BBD) was used to optimize the system's performance with the minimum number of tests possible, as well as to examine the independent variables' impact on the removal efficiency, energy consumption, operating cost, and effluent MB concentration. The electrical potential and electrolyte dosage both improved the MB removal efficiency, since increased electrical potential facilitated production of oxidizing agents and increase in electrolyte dosage translated into an increase in electrical current transfer. As expected, MB removal efficiency increased with longer operational periods. The combined effects of operating time-electrical potential and electrical potential-electrolyte concentration improved the MB removal efficiency. The maximum removal efficiency (99.9%) and lowest operating cost (0.012 $/m3) were obtained for initial pH 4, initial MB concentration 26.5 mg/L, electrolyte concentration 0.6 g/L, electrical potential 3 V, and operating time 30 min. The reaction kinetics was maximum for pH 5, and as the pH increased the reaction rates decreased. Consequent techno-economic assessment showed that electrochemical removal of MB using low-cost and versatile flexible graphite had a competitive advantage.
  • Article
    Citation - WoS: 5
    Citation - Scopus: 7
    Bleach-Containing Automatic Toilet-Bowl Cleaners as Sources of Vocs, Associated Indoor Air Concentrations and Carcinogenic Risk
    (Turkish National Committee for Air Pollution Research (TUNCAP), 2020) Ayrı, İlknur; Genişoğlu, Mesut; Gaygısız, Handan; Sofuoğlu, Aysun; Sofuoğlu, Sait Cemil
    Household cleaning products are sources of volatile organic compounds (VOCs). Bleach containing products are a special case because reactions occur between chloride and their organic content such as surfactants, perfumes, etc., generating VOCs. This study aimed to determine concentration of 13 VOCs in bleach-containing automatic toilet cleaners, to estimate their indoor air concentrations and associated exposure and health risk levels. Experiments with products purchased from supermarkets were conducted in 20-mL headspace vials by placing 1 g of sample with and without water. Solid-phase micro extraction with a DVB/CAR/PDMS fiber assembly was used for adsorption of VOCs from the headspace, and analyzed using a GC-MS. The median carbon tetrachloride and chloroform concentrations of the studied products ranged from 5.03 × 10?3 to 2.37 × 10?2 ?g/g and 2.53 × 10?2 to 2.37 ?g/g, respectively. The modeled 95th percentile indoor air concentrations in a 1.6 m3 bathroom with no ventilation were estimated to be 1 and 20 ?g/m3 for carbon tetrachloride and chloroform, respectively. The 95th percentile carcinogenic risk associated even with the use of the highest content product, 3.72 × 10?7 and 8.62 × 10?7 for carbon tetrachloride and chloroform respectively, were below the acceptable risk. In conclusion, automatic toilet-bowl cleaners were found to be sources of VOCs, but their emission potentials are not high to cause considerable indoor air concentrations over their suggested product lifetime. In turn, carcinogenic risks associated with inhalation exposure are below the de Minimis risk level of 10?6. © 2020
  • Article
    Citation - WoS: 45
    Citation - Scopus: 45
    The First Countrywide Monitoring of Selected Pops: Polychlorinated Biphenyls (pcbs), Polybrominated Diphenyl Ethers (pbdes) and Selected Organochlorine Pesticides (ocps) in the Atmosphere of Turkey
    (Elsevier Ltd., 2018) Kurt Karakuş, Perihan Binnur; Ugranlı Çiçek, Tuğba; Sofuoğlu, Sait Cemil; Çelik, Halil; Güngörmüş, Elif; Gedik, Kadir; Sofuoğlu, Aysun; Ökten, Hatice Eser; Birgül, Aşkın; Alegria, Henry; Jones, Kevin C.
    Atmospheric levels of 43 PCBs, 22 OCPs, and 14 PBDEs were determined in 16 cities at urban and rural sites by passive sampling to generate the first large-scale nationwide dataset of POP residues in Turkey's atmosphere. Sampling campaign was performed from May 2014 to April 2015 with three-month sampling periods at locations on east-west and north-south transects through the country to investigate seasonal and spatial variations, including long range atmospheric transport (LRAT). Factor analysis was conducted to infer on the potential sources. Overall average Σ43PCBs concentration was 108 ± 132 pg/m3. PCB-118 (26.3 ± 44.6 pg/m3) was the top congener, and penta-CBs had the highest contribution with 54.3%. ΣDDTs had the highest annual mean concentration with 134 ± 296 pg/m3 among the OCP groups among which the highest concentration compound was p'p-DDE (97.6 ± 236 pg/m3). Overall average concentration of Σ14PBDEs was 191 ± 329 pg/m3 with the highest contribution from BDE-190 (42%). Comparison of OCPs and PCBs concentrations detected at temperatures which were above and below annual average temperature indicated higher concentrations in the warmer periods, hence significance of secondary emissions for several OCPs and Σ43PCBs, as well as inference as LRAT from secondary emissions. The first nationwide POPs database constructed in this study, point to current use, local secondary emissions, and LRAT for different individual compounds, and indicate the need for regular monitoring. The first country-wide passive sampling of selected POPs showed no unequivocal trends reflecting transitional location of Turkey.
  • Article
    Citation - WoS: 21
    Citation - Scopus: 26
    Indoor Environmental Quality in Chemistry and Chemical Engineering Laboratories at Izmir Institute of Technology
    (Turkish National Committee for Air Pollution Research (TUNCAP), 2015) Ugranlı, Tuğba; Toprak, Melis; Gürsoy, Gül; Çimrin, Arif H.; Sofuoğlu, Sait Cemil
    Indoor air pollution in university research laboratories may be important to building occupants, especially for those who work in the laboratories. In this study, indoor air quality (IAQ) and indoor environmental comfort were investigated in research laboratories of two departments at a university. PM2.5, PM10, TVOC (total volatile organic compounds), and CO concentrations, and three comfort variables which are temperature, relative humidity, and CO2 were measured. PM2.5 concentration was determined gravimetrically by collecting particles on glass fiber filters, whereas the remaining pollutants and comfort variables were measured using a monitoring device. IAQ measurements showed that levels of all pollutants were under the limits in both of the departments except for TVOC in one laboratory which had a mean concentration of 182 ppb. The comfort variables were in the comfort ranges for laboratories in both of the departments except for temperature in one laboratory with a mean value of 30 °C. In conclusion, measures are needed for extensive uses of organic solvents because ventilation may not be sufficient to keep VOC concentrations within the limits, and to provide thermal comfort.