Chemical Engineering / Kimya Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/14

Browse

Search Results

Now showing 1 - 3 of 3
  • Article
    Citation - WoS: 23
    Citation - Scopus: 25
    A Dimensionless Analysis of Heat and Mass Transport in an Adsorber With Thin Fins; Uniform Pressure Approach
    (Elsevier Ltd., 2011) Gediz İliş, Gamze; Mobedi, Moghtada; Ülkü, Semra
    A numerical study on heat and mass transfer in an annular adsorbent bed assisted with radial fins for an isobaric adsorption process is performed. A uniform pressure approach is employed to determine the changes of temperature and adsorbate concentration profiles in the adsorbent bed. The governing equations which are heat transfer equation for the adsorbent bed, mass balance equation for the adsorbent particle, and conduction heat transfer equation for the thin fin are non-dimensionalized in order to reduce number of governing parameters. The number of governing parameters is reduced to four as Kutateladze number, thermal diffusivity ratio, dimensionless fin coefficient and dimensionless parameter of Γ which compares mass diffusion in the adsorbent particle to heat transfer through the adsorbent bed. Temperature and adsorbate concentration contours are plotted for different values of defined dimensionless parameters to discuss heat and mass transfer rate in the bed. The average dimensionless temperature and average adsorbate concentration throughout the adsorption process are also presented to compare heat and mass transfer rate of different cases. The values of dimensionless fin coefficient, Γ number and thermal diffusivity ratio are changed from 0.01 to 100, 1 to 10 -5 and 0.01 to 100, respectively; while the values of Kutateladze number are 1 and 100. The obtained results revealed that heat transfer rate in an adsorbent bed can be enhanced by the fin when the values of thermal diffusivity ratio and fin coefficient are low (i.e., α -=0.01, δ=0.01). Furthermore, the use of fin in an adsorbent bed with low values of γ number (i.e. γ=10 -5) does not increase heat transfer rate, significantly.
  • Article
    Citation - WoS: 12
    Citation - Scopus: 11
    A Parametric Study on Isobaric Adsorption Process in a Closed Adsorbent Bed
    (Elsevier Ltd., 2010) Gediz İliş, Gamze; Mobedi, Moghtada; Ülkü, Semra
    A numerical study on heat and mass transfer in an annular adsorbent bed filled with adsorbent granules for an isobaric adsorption process is performed. In order to reduce the number of independent parameters that influences heat and mass transfer in the bed, the governing equations and related initial and boundary conditions for the problem are non-dimensionalized and this yields two dimensionless parameters as G and Γ. The G dimensionless parameter is the ratio of heat of adsorption to sensible heat stored by adsorbent particle and Γ parameter compares mass diffusion within the adsorbent particle and heat diffusion in the radial direction of the adsorbent bed. The obtained results show that the total dimensionless time for an adsorption process can be reduced by increasing of Γ value. The total dimensionless time is independent from G for low values of Γ (i.e. Γ=105). The results also show that the instantaneous equilibrium model can provide accurate results only for an adsorbent bed with a low value of Γ (i.e. Γ=105). The present study is performed for Γ values from 105 to 1 and G value from 1 to 100. © 2010 Elsevier Ltd.
  • Article
    Citation - WoS: 9
    Citation - Scopus: 11
    Modeling of Hemodialysis Operation
    (Springer Verlag, 2010) Abacı, Hasan Erbil; Alsoy Altınkaya, Sacide
    In this study, a theoretical model was developed to predict the solute concentrations in patients' blood and optimize the efficiency of the hemodialysis operation. The model takes into account simultaneous mass and momentum transfer on the blood side both in radial and axial directions. A key component of the model is the incorporation of the protein adsorption on the inner surface of the membrane. The validity of the model was confirmed with the experimental data available in the literature for two different types of hemodiafilter. To illustrate the importance of including the radial concentration gradients and protein adsorption kinetics in the model, the experimental data were predicted with and without consideration of these effects. The results have shown that assuming uniform concentration in the radial direction or neglecting protein adsorption on the inner surface of the membrane leads to higher error in predicting the experimental data. In addition, significant error can be introduced in the calculation of the dialysis time if protein adsorption is not considered. © 2010 Biomedical Engineering Society.