Rectorate / Rektörlük
Permanent URI for this collectionhttps://hdl.handle.net/11147/6849
Browse
4 results
Search Results
Article Citation - WoS: 5Citation - Scopus: 32Performance of the Cms Muon Trigger System in Proton-Proton Collisions at ?s = 13 Tev(IOP Publishing Ltd, 2021) CMS Collaboration; Karapınar, GülerThe muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 × 10 cm s while delivering proton-proton collisions at ?s = 13 TeV. The challenge for the trigger system of the CMS experiment is to reduce the registered event rate from about 40 MHz to about 1 kHz. Significant improvements important for the success of the CMS physics program have been made to the muon trigger system via improved muon reconstruction and identification algorithms since the end of Run 1 and throughout the Run 2 data-taking period. The new algorithms maintain the acceptance of the muon triggers at the same or even lower rate throughout the data-taking period despite the increasing number of additional proton-proton interactions in each LHC bunch crossing. In this paper, the algorithms used in 2015 and 2016 and their improvements throughout 2017 and 2018 are described. Measurements of the CMS muon trigger performance for this data-taking period are presented, including efficiencies, transverse momentum resolution, trigger rates, and the purity of the selected muon sample. This paper focuses on the single- and double-muon triggers with the lowest sustainable transverse momentum thresholds used by CMS. The efficiency is measured in a transverse momentum range from 8 to several hundred GeV. © 2021 CERN for the benefit of the CMS collaboration.Article Citation - WoS: 31Citation - Scopus: 65The Performance of the Cms Muon Detector in Proton-Proton Collisions at Root S=7 Tev at the Lhc(IOP Publishing Ltd., 2013) Karapınar, GülerThe performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at root s = 7TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 pb(-1). The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial resolution per chamber was 80-120 mu m in the DTs, 40-150 mu m in the CSCs, and 0.8-1.2 cm in the RPCs. The time resolution achievable was 3 ns or better per chamber for all 3 systems. The efficiency for reconstructing hits and track segments originating from muons traversing the muon chambers was in the range 95-98%. The CSC and DT systems provided muon track segments for the CMS trigger with over 96% efficiency, and identified the correct triggering bunch crossing in over 99.5% of such events. The measured performance is well reproduced by Monte Carlo simulation of the muon system down to the level of individual channel response. The results confirm the high efficiency of the muon system, the robustness of the design against hardware failures, and its effectiveness in the discrimination of backgrounds.Article Citation - WoS: 181Citation - Scopus: 382Performance of the Cms Muon Detector and Muon Reconstruction With Proton-Proton Collisions at Root S=13 Tev(IOP Publishing Ltd., 2018) Karapınar, Güler; CMS CollaborationThe CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy root s = 13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.Article Citation - WoS: 86Citation - Scopus: 79Performance of Cms Muon Reconstruction in Cosmic-Ray Events(IOP Publishing Ltd., 2010) Demir, Durmuş Ali; Karapınar, GülerThe performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10GeV/c to about 1% at 500 GeV/c.
