Energy Systems Engineering / Enerji Sistemleri Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4752

Browse

Search Results

Now showing 1 - 5 of 5
  • Article
    Citation - WoS: 8
    Citation - Scopus: 6
    Effect of external electric field on fluidization of rodlike particles using CFD-DEM
    (American Chemical Society, 2024) Kazemi, Saman; Aali, Hamed; Larijani, Roxana Saghafian; Zarghami, Reza; Liu, Helei; Mostoufi, Navid
    Given the significant impact of an external electric field on fluidized bed hydrodynamics and the practical importance of rodlike particles, this study examines the behavior of a fluidized bed containing rodlike particles under various external electric fields. Simulations were performed using a coupled computational fluid dynamics-discrete element method, and rodlike particles were generated using a multisphere approach aided by quaternions. The effect of different vertical and horizontal external electric fields on the orientation of particles was investigated. Also, the effect of particle size on their orientation in the presence of constant vertical and horizontal external electric fields was explored in this work. The results showed that increasing the electric field strength and reducing the size of rodlike particles lead to an increment in the tendency of particles to become oriented along the direction of the electric field. Moreover, the effect of the external electric field at various inlet gas velocities on the probability distribution of the porosity in the bed was studied. Finally, the effect of vertical and horizontal electric fields on the bubble diameter was examined. This study offers a deeper understanding of the fluidization of rodlike particles in the presence of an electric field, and its findings can be applied to design and optimize related processes.
  • Article
    Citation - WoS: 17
    Citation - Scopus: 24
    A Gis-Based Fahp and Fedas Analysis Framework for Suitable Site Selection of a Hybrid Offshore Wind and Solar Power Plant
    (Elsevier B.V., 2023) Karipoğlu, Fatih; Ozturk, S.; Efe, B.
    This study presents a Geographic Information System (GIS) based suitable site selection methodology for a hybrid system that includes offshore wind and solar PV. The methodology utilizes open source databases about decision criteria and applies this data using GIS to determine suitable sites for offshore wind and solar PV systems. For the assessment of multi-criteria which affect the potential hybrid energy power plants and the determination of the best suitable areas, Fuzzy Analytical Hierarchy Process (FAHP) and Fuzzy Evaluation based on Distance Average Solution (FEDAS) are used in the study. Results show that technical criteria has the priority weight of 0.60 while the weight of social criteria is about 0.07. Among sub-criteria, the wind speed has the highest priority weight while distance to port and visibility are the highest criteria of priority weight under economic and social main criteria, respectively. Among the alternatives, Area 2 (A-2) is determined as the best alternative for hybrid offshore power plants in the study area. This proposed methodology can be utilized by decision-makers to determine the best suitable locations for hybrid offshore wind and solar PV systems at any location. This paper suggests a new approach integrating GIS, fuzzy setbased AHP and EDAS as a novelty. © 2023 International Energy Initiative
  • Article
    Citation - WoS: 45
    Citation - Scopus: 31
    Highly Efficient Treatment of Petrochemical Spent Caustic Effluent Via Electro-Fenton Process for Cod and Toc Removal: Optimization and Experimental
    (Springer, 2023) Gholami, Asma; Mousavi, Seyed Borhan; Heris, Saeed Zeinali; Mohammadpourfard, Mousa
    Caustic is commonly used in oil and gas refineries to remove CO2, H2S, organic sulfur, and acidic compounds; however, spent caustic must be treated considering the type of wastewater in refinery and petrochemical units due to their hazardous characteristics. This research aims to reduce the chemical oxygen demand (COD) and the total organic carbon (TOC) from the used caustic effluent of the olefin unit of Ilam Petrochemical Company employing the electro-Fenton method. The affecting parameters, such as H2O2 concentration, reaction time, pH, and current density on the COD and TOC removal rate, were investigated. An experimental design by response surface methodology (RSM) based on the Box–Behnken method with the considered factors was considered to study the setup’s effectiveness and optimize the conditions. The outcomes revealed that by increasing the H2O2 concentration from 11 to 18 mgL, the COD removal efficiency was enhanced from 68 to 93%. On the other hand, by increasing the reaction time after 15 min, the COD and TOC removal efficiency decreased. The same trend was observed by increasing the current density after the optimal value. The optimal conditions were acquired at pH = 4, current density = 20 mAcm2, H2O2 concentration = 18 mgL, and reaction time = 15 min. The promising results confirmed that the electro-Fenton could be an excellent treatment technique in Ilam Petrochemical Unit as a spent caustic treatment. © 2023, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 10
    Characterization of Sb Scaling and Fluids in Saline Geothermal Power Plants: a Case Study for Germencik Region (büyük Menderes Graben, Turkey)
    (Pergamon-Elsevier Science Ltd, 2021) Tonkul, Serhat; Baba, Alper; Demir, Mustafa M.; Regenspurg, Simona
    Turkey is located on the seismically active Alpine-Himalayan belt. Although tectonic activity causes seismicity in the Anatolian plate, it also constitutes an important geothermal energy resource. Today, geothermal energy production is heavily concentrated in Turkey's Western Anatolia region. Graben systems in this region are very suitable for geothermal resources. The Buyuk Menderes Graben (BMG) is an area of complex geology with active tectonics and high geothermal potential power. Germencik (Aydin) is located in the BMG, where the geothermal waters include mainly Na-Cl-HCO3 water types. This study examined the stibnite scaling formed in the preheater system of the Germencik Geothermal Field (GGF). The formation of the stibnite scaling on the preheater system dramatically reduces the energy harvesting of the GGF. Considering the stibnite scaling in the surface equipment, the optimum reinjection temperature was determined as 95 degrees C to prevent stibnite scaling in the GGF.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 5
    Electrooxidation of Glycerol on Monometallic and Bimetallic Catalysts-Containing Porous Carbon Cloth Electrodes in an Alkaline Medium
    (Electrochemical Society, Inc., 2021) Çağlar, Başar; El Hassan, Youssef; Basak, Oğuzhan; Hepbaşlı, Arif
    The electrooxidation of glycerol was studied on monometallic (Pt/C, Co/C, Ni/C, Cu/C) and bimetallic catalysts (PtCo/C, PtNi/C, PtCu/C) - containing porous carbon cloth electrodes in an alkaline medium to gain insight about the potentials of electrodes for simultaneous hydrogen and chemical production. Physical and chemical properties of catalysts were characterized by using X-ray diffraction, X-ray photoemission spectroscopy, and transmission electron microscopy while electrochemical characteristics of electrodes were investigated by cyclic voltammetry, choronoamperometry, and electrochemical impedance spectroscopy. Bimetallic catalysts-containing electrodes showed higher glycerol electrooxidation activities and stabilities compared to monometallic catalysts-containing electrodes. The highest activity was observed on the PtCu/C-containing electrode due to its higher electrochemical active surface area and low kinetic and mass transfer resistance. It was also found that the presence of porous carbon cloth had a considerable effect on the glycerol electrooxidation activity.