Energy Systems Engineering / Enerji Sistemleri Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4752

Browse

Search Results

Now showing 1 - 7 of 7
  • Article
    Citation - WoS: 26
    Citation - Scopus: 25
    Biomass Driven Polygeneration Systems: a Review of Recent Progress and Future Prospects
    (Elsevier, 2023) Tabriz, Zahra Hajimohammadi; Khani, Leyla; Mohammadpourfard, Mousa; Gökçen Akkurt, Gülden
    Biomass is the most widely used renewable energy source which is highly appreciated due to its high availability and non-intermittent nature. Considering problems such as reduction of fossil fuels, global warming, and emission of greenhouse gases, lack of attention to the existing situation may cause irreversible damage to the future of the planet. In addition to using renewable energy sources, improving the efficiency of systems will also be helpful. Polygeneration systems play an important role in increasing efficiency and reducing pollution. So, the use of biomass in polygeneration systems seems to be a great approach for sustainable development. Recent studies on biomass-based polygeneration systems have focused on how to use biomass and integrate diverse subsystems to achieve the best performance from energy and exergy viewpoints. The present paper reviews biomass-based systems, and the parameters affecting the performance of these systems. The literature review shows that the high exergy destruction rate in the gasifiers is the most frequent problem among recent articles. In addition, despite the advantages of anaerobic digestion process, the number of studies conducted on the use of this method for biomass conversion is small. In the end, results, limitations, and future outlooks of these systems are discussed.
  • Article
    Citation - WoS: 20
    Citation - Scopus: 18
    Optimization of the Integrated Orc and Carbon Capture Units Coupled To the Refinery Furnace With the Rsm-Bbd Method
    (Elsevier, 2022) Nazerifard, Reza; Mohammadpourfard, Mousa; Heris, Saeed Zeinali
    To recover waste heat and reduce the CO2 emissions into the atmosphere, an integrated system of organic Rankine cycle and post-combustion carbon capture unit coupled with furnaces of a refinery located in Tabriz, East Azerbaijan, Iran has been presented. To assess the performances of the proposed system, thermodynamic and economic analyses are performed. The organic Rankine cycle was optimized by selecting the suitable working fluid with optimal operating conditions among the primary considered ones through multi-objective optimization. Then, the response surface methodology combined with the Box-Behnken design was employed to evaluate the effects of decision variables and their interaction on the CO2 capture cost and attain the optimal conditions. The results indicate that the R-245fa is the best working fluids among the selected ones. According to the results, the flue gas inlet temperature into the absorber and lean loading are the terms of the model that have a significant impact on the output response. In the optimum setting of the decision variables, the CO2 capture cost equals 81.60 $/tCO2 and 81.90 $/tCO2 for ORC+CC and DCC+CC processes, respectively. Furthermore, due to the absence of a turbine in the DCC+CC system, its equivalent work is 28 % higher than the ORC+CC system. Also, the amine regeneration energy is responsible for 91.47 % and 86.15 % of the variable operating cost of the optimal ORC+CC and optimal DCC+CC, respectively.
  • Article
    Citation - WoS: 9
    Citation - Scopus: 10
    Energy and Exergy Analysis of Combined Power, Methanol, and Light Olefin Generation System Fed With Shale Gas
    (Elsevier, 2022) Khani, Leyla; Tabriz, Zahra Hajimohammadi; Mohammadpourfard, Mousa; Gökçen Akkurt, Gülden
    Environmental problems and limitations of fossil fuel resources, especially crude oil, have intensified the importance of using cleaner and cheaper fuels besides enhancing energy conversion processes. Therefore, a novel power, methanol, and light olefin multi-generation system is designed and modeled in this paper. Chemical looping reforming, chemical looping combustion cycles, and Rankine power system are combined with methanol and light olefin production processes. The input fuel of the system is shale gas. The mass, energy, and exergy balance equations are applied for each system unit as a steady-state control volume to assess its thermodynamic operation. Then, the effects on the system performance of critical parameters are studied comprehensively. The results show that the necessary syngas can be supplied when 71.5% of the inlet shale gas is used in the steam reforming reactor of the chemical looping reforming cycle, and the steam to fuel ratio and carbon dioxide to fuel ratio are 0.61. Furthermore, if 31% of the produced methanol is consumed in the olefin production unit, the system energy and exergy efficiencies are achieved at 67.3% and 71.5%, respectively. In this case, the carbon dioxide flow rate is 800 kmol/hr, separated and stored in the chemical looping combustion cycle, leading to a clean thermodynamic system.
  • Article
    Citation - WoS: 71
    Citation - Scopus: 78
    Investigation of H2o2/Uv Advanced Oxidation Process on the Removal Rate of Coliforms From the Industrial Effluent: a Pilot-Scale Study
    (Elsevier, 2022) Ashrafivala, Meisam; Mousavi, Seyed Borhan; Zeinali Heris, Saeed; Heidari, Mohammad; Mohammadpourfard, Mousa; Aslani, Hassan
    Wastewater recycling and reuse is very important, specially in countries with water shortage problem. Disinfection is very crucial step of wastewater treatment, particulary from the reuse and environmental protection point of view. In this research, the efficiency of the advanced oxidation process using UV and H2O2 combination was investigated on fecal coliform (FC) inactivation from a real industrial effluent; furthermore, the optimal condition for disinfection of the effluent using various parameters such as pH, H2O2 concentration, and contact time was determined. Based on the acquired outcomes, by pH decline from 11 to 7 and 3 inactivation rate increased (6.7% and 20.9%, sequentially), indicating the efficacy of acidic condition on the process. Increasing H2O2 concentration from 5 mg/L to 15 mg/L, 25 mg/L, and 35 mg/L, was led to increase FC inactivation by 16.6%, 29.75%, and 36.33%, respectively. Considering contcat time impact on the process performance, our findings revealed that the best efficiency obtained after 40 (s) contact time. It can be concluded that the combined UV/H2O2 is more potent than single UV and H2O2 process, making it possible to reach irrigation standards.
  • Article
    Citation - WoS: 38
    Citation - Scopus: 40
    Exergoeconomic Analysis and Optimization of a High-Efficient Multi-Generation System Powered by Sabalan (savalan) Geothermal Power Plant Including Branched Gax Cycle and Electrolyzer Unit
    (Elsevier, 2022) Seiiedhoseiny, Miryasin; Khani, Leyla; Mohammadpourfard, Mousa; Gökçen Akkurt, Gülden
    Employing suitable subsystems to reach high efficiency and low cost in renewable-based power plants is more crucial. The geothermal energy heat source is located in many countries, but this has never been investigated to run a multi-generation system, including a branched GAX cycle and an electrolyzer. In this path, a high-efficient multi-generation system powered by a Sabalan (Savalan) geothermal power plant consisting of a single flash cycle, a branched GAX cycle, and an electrolyzer is presented and scrutinized from thermodynamic and exergoeconomic viewpoints. In the end, a two-objective optimization, by using the Total Unit Cost of Product (TUCP) and energy efficiency as objectives, is utilized to find the optimum operating conditions. Critiques and studies of variables reveal that the produced hydrogen rate remains unchanged at 5.655 kg/h by changing the degassing value and temperature of the generator, condenser 2, and evaporator. By increasing the flash tank pressure from 5.2 bar to 7 bar, the cooling and heating loads rise about 108.4%, while the net electricity falls from 3977 kW to 3506 kW. Interestingly, the TUCP has a minimum value at the evaporator temperature of 273 K and condenser 2 temperature of 322.3 K. The optimization results indicate the values of the produced hydrogen rate and net electricity with 5.85 kg/h and 4187 kW are more than those of the base case. Also, the optimal values are 7.046 $/GJ, 36.82%, and 65.42% for the TUCP and energy and exergy efficiencies, respectively.
  • Article
    Citation - WoS: 10
    Citation - Scopus: 10
    Hydrogeology and Hydrogeochemistry of the Geothermal Systems and Its Direct Use Application: Balçova-Narlıdere Geothermal System, İzmir, Turkey
    (Elsevier, 2022) Baba, Alper; Sözbilir, Hasan; Sayık, Tolga; Arslan, Sinan; Uzelli, Taygun; Tonkul, Serhat; Demir, Mustafa Muammer
    The Balçova-Narlıdere geothermal system, located in western Turkey, is an extensional domain type geothermal play. Geological, hydrogeological, and geothermal studies have been done in the Balçova-Narlıdere geothermal field since 1960. As a result of these studies, production and research wells were drilled in the area by both the public and private sectors. Of the 37 wells drilled in the Balçova-Narlıdere geothermal field, 26 were drilled by İzmir Geothermal Energy Company Inc. (16 productions, 4 re-injection, 4 gradientst, 2 unused) and 11 by the İzmir Governorship Investment Monitoring and Coordination Department and companies in the private sectors. There are two reservoirs, one shallow and one deep, in the geothermal field. Well depths are less than 200 m in the shallow reservoir. The deep production wells have depths ranging from 400 to 1,100 m and reservoir temperatures reaching 140 °C. The electrical conductivity (EC) values in the shallow production wells range from 1,200 to 1,500 µS/cm. EC values in the deep production wells vary from 1,871 to 2,025 µS/cm, and all geothermal fluids in the field are mineral-rich waters. In the İzmir geothermal district heating system, the newest technologies are used, and operational costs are very low. İzmir Geothermal Energy Company Inc. has been operating since 1996 and has reached 38,460 residences. The current capacity of the system is approximately 160 MWt. Cooling systems continue to spread in Turkey, focusing on electric air conditioning systems and geothermal heating systems, but both economic and applicability problems have slowed the expansion of cooling systems. However, İzmir Geothermal Energy Company Inc. began operating its first geothermal cooling application in Balçova in 2018, cooling 1,900 m2 of the indoor area by lithium bromide absorption and 90/85 °C geothermal temperature regime by supplying 6/9 °C clean cold water to the coolers in the buildings. These results show that the extensional domain type geothermal system in the Balçova-Narlıdere region is suitable for both heating and cooling applications
  • Article
    Citation - WoS: 50
    Citation - Scopus: 56
    Gis-Based Optimal Site Selection for the Solar-Powered Hydrogen Fuel Charge Stations
    (Elsevier, 2022) Karipoğlu, Fatih; Genç, Mustafa Serdar; Akarsu, Beyhan
    Energy consumption which is the most critical input in daily life is increasing constantly because of the growth of the world population and development of the devices. The transportation industry which is responsible for almost half of all worldwide emissions is switching to innovative devices run on renewable energy. Renewable-powered charging stations are important for reducing the environmental impact of vehicles. The objective of the study was to determine the best hydrogen charge station locations and rates which are supplied by coupled solar power plants. The GIS-based assessment was carried out with proper data from data sources such as Copernicus Land Monitoring (CLC 2018), and Global Solar Atlas (GSA). For the determination of suitable regions for solar power plants, eight sub-criteria were assessed under technical (C1), accessibility (C2), and environmental (C3) main criteria. Afterward, the obtained result map layer and suitability of the six determined water bodies, located in the study region, were investigated by assuming the buffer zone value. Results showed that the study area had suitable regions of 38.1 km2 indicating that %22.4 of it was convenient for the solar power plant investments. While Cihanbeyli Lake does not have the highest suitable region, the biggest suitable area inside the buffer zone of lakes was determined as the Ağcaşayar Dam. The maximum annual solar production level is obtained as 1,919 MWh/year in the Ağcaşayar Dam, with a hydrogen production of 34,933 tons/year. Consequently, the Ağcaşayar Dam is the best suitable destination for a hydrogen fuel station in Kayseri.