Energy Systems Engineering / Enerji Sistemleri Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/4752
Browse
10 results
Search Results
Conference Object Citation - Scopus: 2Co2 Capture by Pei-Impregnated Alumina Sorbents(ISRES Publishing, 2023) Turgut, Furkan; Kostik, Simge; Erdoğan, Barış; Çağlar, BaşarDirect air capture (DAC) or direct CO2 extraction from ambient air is a promising approach to reduce greenhouse gas emissions caused by both distributed (location independent) and point sources (location specific). Solid sorbents have been considered as more effective for DAC compared to the liquid counterpart since they have a faster kinetic and avoid volatile and heat losses due to the absence of evaporation of liquids. In this study, the alumina-supported polyethyleneimine (PEI) material was chosen as solid sorbents and their CO2 capture performance for different PEI loadings (20, 35, 50 wt%), flow rate (15, 30, 45 L/h) and adsorption temperatures (30, 40, 50, 60 °C) was investigated. Sorbents were prepared by using wetness impregnation method and their physical and chemical properties were characterized by several techniques such as N2 adsorption-desorption (surface area, pore size and volume), Scanning Electron Microscopy-SEM (surface morphology, surface chemical composition). The CO2 capture performance of sorbents were analyzed under different CO2 concentrations and the cyclic (adsorption-desorption) behavior of the sorbents were tested. The results show that alumina-supported PEI adsorbents are promising materials for CO2 capture with high CO2 adsorption capacity and stability. © 2023 Published by ISRES.Conference Object Citation - Scopus: 1Comfort Based Investigation on Historic Libraries for User Satisfaction and Preservation of Paper-Based Collections(IOP Publishing, 2021) Turhan, Cihan; Topan, Çağrı; Durmuş Arsan, Zeynep; Göksal Özbalta, Türkan; Gökçen Akkurt, GüldenHistoric libraries preserve cultural heritage values while housing rare manuscripts and paper-based collections. The collections in the libraries are deteriorated chemically, biologically and mechanically due to inappropriate indoor environment conditions such as temperature and relative humidity fluctuations and microbiological conditions. Apart from preserving vulnerable paper-based collections, accommodating of a considerable thermal comfort level for visitors is essential in historic libraries. The aim of this study is to analyse indoor environment of a historic library in terms of thermal comfort and preventive conservation of paper-based collections. Izmir National Library, built in 1933, is selected as a case study. Indoor air temperature, relative humidity and air velocity in the library were monitored with a one-year measurement campaign. Meanwhile, thermal comfort of the visitors was assessed with PMV/PPD indices and thermal sensation surveys. The results show that high chemical degradation risk is detected in the library while biological and mechanical degradations are in the low risk zone. On the other hand, 87% and 93% of the visitors feel thermally satisfied in heating and cooling seasons, respectively.Conference Object Citation - Scopus: 11Wind-Solar Site Selection Using a Gis-Mcdm Approach With an Application in Kayseri Province/Turkey(Institute of Electrical and Electronics Engineers Inc., 2021) Genç, Mustafa Serdar; Karipoğlu, FatihRenewable and sustainable energy sources such as wind, biomass, geothermal and solar are defined as a less harmfully to environment than other fossil fuels reserves. At the last decade, the demand of energy because of the rising of industrialization and population is increasing in Turkey. Thus, investments on renewable energy sources especially wind and solar energy systems are increasing rapidly because of unlicensed energy production legislation published by Turkish Ministry of Energy and Natural Sources. Although Turkey has high solar and wind capacity, there has not been develop a tool to determine the suitable regions for hybrid energy systems. In this study, geographical information systems (GIS) and Multi-criteria-base method (MCDM) are used to determine the suitable regions for wind-solar hybrid energy systems of Kayseri Province under potential and environmental impacts. The results shows (2.080 km2) %12.3 of Kayseri is suitable for hybrid energy system investment. © 2021 IEEE.Conference Object Citation - WoS: 1Citation - Scopus: 3Green Smart Cities: Living Healthily With Every Breath(Institute of Electrical and Electronics Engineers Inc., 2019) Turhan, Cihan; Atalay, Ali Serdar; Gökçen Akkurt, GüldenFifty-four percent of the world's population lives in big cities and it is projected to increase to nearly 70% by 2050s. Rapid and dense urbanization leads to smart cities which improve the quality of lives of the citizens. Therefore, development of smart cities is becoming vital. The quality of the citizens is affected by many factors including poor air quality, increased pollutants and microclimates called urban heat islands. The URBAN GreenUP project, initiated in June 2017, is a project funded under the European Union's Horizon 2020 programme. The main objective of the project is the development, application and replication of re-naturing Urban Plans in a number of European cities. In this study, measurement of nature-based solutions for mitigation of urban heat island effect and improvement of air quality for Urban GreenUP project in Izmir, will be introduced.Conference Object Molecular Dynamics Study of the Thermal Conductivity of Graphene Coated Copper(Avestia Publishing, 2019) Toprak, Kasım; Ersavaş, GizemIn this study, the thermal conductivity of various size of pure copper, pure graphene and, different number of layer graphene coated copper models are studied using non-equilibrium molecular dynamics (NEMD) simulations. Our findings show that the thermal conductivity of graphene coated copper is higher than the uncoated ones. Furthermore, results also indicate that single layer graphene (SLG) model has the highest thermal conductivity as compared to the other model. Even though multiple layer graphene (MLG) has lower thermal conductivity value compare to SLG, this study shows that the thermal conductivity of MLG coated copper has higher thermal conductivity than SLG coated one. The most important finding in this study suggests that the thermal conductivity of copper can be improved using high thermal conductivity materials like graphene. © 2019, Avestia Publishing.Conference Object Citation - Scopus: 1Offshore Wind Energy Estimation in the Bay of Bengal With Satellite Wind Measurement(IEEE, 2019) Nadi, Navilla Rahman; Badger, Merete; Bingöl, FerhatThe objective of this paper is to obtain appropriate offshore location in the Bay of Bengal, Bangladesh for further development of wind energy. Through analyzing the previous published works, no offshore wind energy estimation has been found related to the Bay of Bengal. Therefore, this study can be claimed as the first footstep towards offshore wind energy analysis for this region. Generally, it is difficult to find offshore wind data relative to the wind turbine hub heights, thus a starting point is necessary to identify the possible wind power density of the region. In such scenario, Synthetic Aperture radars (SAR) have proven useful in previous studies. In this study, SAR based dataset- ENVISAT ASAR has been used for Wind Atlas generation of the Bay of Bengal. Furthermore, a comparative study has been performed with Global Wind Atlas (GWA) to determine a potential offshore wind farm production in a reasonable location at the bay. The annual energy production of that offshore windfarm has been analyzed by combining SAR, GWA and ASCAT datasets. Through ASAR based Wind Atlas and GWA comparison, some differences have been found where there are less samples from the ASAR datasets. Thus, Weibull statistical analysis are performed to have a better Weibull fitting and accurate estimation of Annual Energy production (AEP). The study summarizes that, satellite datasets can be a very useful method to detect potential zone if compared with any long time statistical result and bathymetry data together. © 2019 IEEE.Conference Object Citation - WoS: 14Citation - Scopus: 16Drying of Olive Leaves in a Geothermal Dryer and Determination of Quality Parameters of Dried Product(Elsevier, 2019) Helvacı, Hüseyin Utku; Menon, Abhay; Aydemir, Levent Yurdaer; Korel, Figen; Gökçen Akkurt, GüldenIn this study, a cabinet type geothermal dryer was designed, operated and tested for drying olive leaves with minimum losses of phenolic content and antioxidant capacity by optimization of drying conditions. Two factors; face centered central composite design was applied and response surface methodology was used to optimize the drying conditions of olive leaves. The results indicate that phenolic content stability were mainly affected by air temperature, whereas antioxidant capacity is affected by both air temperature and velocity (p<0.05). The optimal drying conditions were found to be at 50°C of air temperature and 1 m/s of air velocity for the minimum losses of determined quality parameters, where 88.8% of phenolic content and 95.3% of antioxidant capacity were recovered.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Conference Object Citation - WoS: 21Citation - Scopus: 27Applying Underfloor Heating System for Improvement of Thermal Comfort in Historic Mosques: the Case Study of Salepçioglu Mosque, Izmir, Turkey(Elsevier Ltd., 2017) Bughrara, Khaled S. M.; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.Conference Object Citation - WoS: 1Citation - Scopus: 2Analysis and Application of Advanced Control Strategies To a Heating Element Nonlinear Model(IOP Publishing Ltd., 2017) Turhan, Cihan; Simani, Silvio; Zajic, Ivan; Gökçen Akkurt, GüldenThis paper presents the design of different control strategies applied to a heating element nonlinear model. The description of this heating element was obtained exploiting a data-driven and physically meaningful nonlinear continuous-time model, which represents a test-bed used in passive air conditioning for sustainable housing applications. This model has low complexity while achieving high simulation performance. The physical meaningfulness of the model provides an enhanced insight into the performance and functionality of the system. In return, this information can be used during the system simulation and improved model- based and data-driven control designs for tight temperature regulation. The main purpose of this study is thus to give several examples of viable and practical designs of control schemes with application to this heating element model. Moreover, extensive simulations and Monte- Carlo analysis are the tools for assessing experimentally the main features of the proposed control schemes, in the presence of modelling and measurement errors. These developed control methods are also compared in order to evaluate advantages and drawbacks of the considered solutions. Finally, the exploited simulation tools can serve to highlight the potential application of the proposed control strategies to real air conditioning systems.