Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7755

Browse

Search Results

Now showing 1 - 8 of 8
  • Article
    Citation - WoS: 16
    Citation - Scopus: 20
    Groundwater Recharge Estimation Using Hydrus 1d Model in Alaşehir Sub-Basin of Gediz Basin in Turkey
    (Springer Verlag, 2019) Tonkul, Serhat; Baba, Alper; Tonkul, Serhat; Durukan, Seda; Demirkesen, Ali Can; Demirkesen, Ali Can; Tayfur, Gökmen; Baba, Alper; 03.06. Department of Energy Systems Engineering; 02.03. Department of City and Regional Planning; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 02. Faculty of Architecture; 01. Izmir Institute of Technology
    Gediz Basin, located in the western part of Turkey constituting 2% land of the country, has an important groundwater potential in the area. Alasehir sub-basin, located in the southeast of the Gediz Basin and subject to the extensive withdrawal for the irrigation, constitutes the study area. Natural recharge to the sub-basin due to precipitation is numerically investigated in this study. For this purpose, 25 research wells, whose depths range from 20 to 50 m, were drilled to observe the recharge and collect the necessary field data for the numerical model. Meteorological data were collected from 3 weather stations installed in the study area. The numerical model HYDRUS was calibrated using the field water content data. Soil characterization was done on the core samples; the aquifer characterization was performed, and the alluvial aquifer recharge due to precipitation was calculated. As a result, the computed recharge value ranges from 21.78 to 68.52 mm, with an average value of 43.09 mm. According to the numerical model, this amount of recharge corresponds to 10% of the amount of annual rainfall.
  • Master Thesis
    Natural Groundwater Recharge in the Alaşehir Sub-Basin (gediz Basin, Turkey)
    (Izmir Institute of Technology, 2018) Tonkul, Serhat; Tonkul, Serhat; Baba, Alper; Baba, Alper; Şimşek, Celalettin; 03.06. Department of Energy Systems Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    The increase in water utilization due to climate change in recent years, as well as excessively growing population causes to an increase in usage of groundwater and threatens water resources. Dams and artificial lakes are being constructed to ensure the sustainability of water resources, but there is much evaporation on large surface of these structures. Due to reason that the evaporation losses are not experienced, the groundwater recharge by direct rainfall becomes important. Groundwater recharge protects the water without too much evaporation in the basins and increases the potential of water resources and ensures sustainability. The aim of this study is to determine alluvial aquifer recharge in Alaşehir (Manisa) sub-basin using numerical and chemical methods. In addition to this aim, the mechanism of mixing of groundwater and geothermal fluid has also been examined. The Gediz Basin, located in the west of Turkey constitutes 2% of the country, has an important groundwater potential in the area where it is used. The Alasehir sub-basin, located in the southeast of the Gediz Basin and having extensive withdrawal for irrigation, constitutes the study area. Alluvial aquifer is the main groundwater bearing lithological unit in the plain. Twenty-five research wells, which is ranging from 20 m to 50 m in depth, were opened for the calculation of the recharge of the aquifer. Soil characterization was done on the core samples and the aquifer characterization was performed and the alluvial aquifer recharge was calculated. As a result, the recharge value of annual precipitation is range from 21.78 mm to 68.52 mm and average recharge from precipitation is 43.09 mm in the wells which are opened into the alluvium aquifer. According to the numerical model, this amount of recharge corresponds to 10% of the amount of annual rainfall. This estimated recharge ratio directly represents recharge from precipitation into the aquifer. According to the results of the chemical method, it is understood that the average recharge value from precipitation is 16.38%. In addition, the mixing ratio of the groundwater and geothermal fluid is 17% in the sub-basin. Keywords Aquifer Characterization, Alaşehir, Precipitation Recharge, Numerical Modelling
  • Article
    Citation - WoS: 18
    Citation - Scopus: 22
    The Health Risk Associated With Chronic Diseases in Villages With High Arsenic Levels in Drinking Water Supplies
    (Springer Verlag, 2017) Gündüz, Orhan; Baba, Alper; Gündüz, Orhan; Baba, Alper; Elçi, Alper; Gürleyük, Hakan; Mutlu, Merdiye; Çakır, Ayşe; 03.07. Department of Environmental Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    This study is intended to compare and assess the distribution and possible causes of current chronic diseases in villages with high arsenic levels in drinking water supplies. It is a cross-sectional epidemiological research that analyzes the frequency and underlying risk factors of chronic diseases in villages with varying levels of arsenic exposure through drinking water. Sample space of study included 1003 individuals, 614 of whom were from villages with high arsenic levels in drinking water and remaining 389 were from two control villages with below-limit arsenic levels in drinking water. While nutritional habits and living environments of two groups were similar, cigarette smoking and alcohol use were higher in villages with low arsenic levels. Mini mental state examination test results in 60+ age group were lower in villages with high arsenic levels. Although no statistically significant differences were detected in chronic disease occurrence between the groups, the number of cases was higher in villages with higher percentage of cigarette smoking and alcohol use. Moreover, cases of lung, colon, and stomach cancers were higher in villages with high arsenic levels in drinking water supplies.
  • Article
    Citation - WoS: 20
    Citation - Scopus: 22
    Modeling of Seawater Intrusion in a Coastal Aquifer of Karaburun Peninsula, Western Turkey
    (Springer Verlag, 2017) Mansour, Ahmed Y. S.; Baba, Alper; Gündüz, Orhan; Baba, Alper; Elçi, Alper; Murathan, Alim; Sözbilir, Hasan; 03.07. Department of Environmental Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Seawater intrusion is a major problem to freshwater resources especially in coastal areas where fresh groundwater is surrounded and could be easily influenced by seawater. This study presents the development of a conceptual and numerical model for the coastal aquifer of Karareis region (Karaburun Peninsula) in the western part of Turkey. The study also presents the interpretation and the analysis of the time series data of groundwater levels recorded by data loggers. The SEAWAT model is used in this study to solve the density-dependent flow field and seawater intrusion in the coastal aquifer that is under excessive pumping particularly during summer months. The model was calibrated using the average values of a 1-year dataset and further verified by the average values of another year. Five potential scenarios were analyzed to understand the effects of pumping and climate change on groundwater levels and the extent of seawater intrusion in the next 10 years. The result of the analysis demonstrated high levels of electrical conductivity and chloride along the coastal part of the study area. As a result of the numerical model, seawater intrusion is simulated to move about 420 m toward the land in the next 10 years under “increased pumping” scenario, while a slight change in water level and TDS concentrations was observed in “climate change” scenario. Results also revealed that a reduction in the pumping rate from Karareis wells will be necessary to protect fresh groundwater from contamination by seawater.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 17
    Blowout Mechanism of Alasehir (turkey) Geothermal Field and Its Effects on Groundwater Chemistry
    (Springer Verlag, 2017) Rabet, Rita Sandrina; Baba, Alper; Şimşek, Celalettin; Baba, Alper; Murathan, Alim; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Anatolia region is one of the most seismically active regions in the world and has a considerably high level of geothermal energy potential. Some of these geothermal resources have been used for power generation and direct heating. Most of the high enthalpy geothermal systems are located in western part of Turkey. Alasehir is the most important geothermal site in western part of Turkey. Many geothermal wells have been drilled in Alasehir Plain to produce the geothermal fluid from the deep reservoir in the last 10 years. A blowout accident happened during a geothermal well drilling operation in Alasehir Plain, and significant amount of geothermal fluid surfaced out along the fault zone in three locations. When drilling string entered the reservoir rock about 1000 m, blowout occurred. As the well head preventer system was closed because of the blowout, high-pressure fluid surfaced out along the fault zone cutting the Neogene formation. In order to understand the geothermal fluid effects on groundwater chemistry, physical and chemical compositions of local cold groundwater were monitored from May 2012 to September 2014 in the study area. The geothermal fluid was found to be of Na–HCO3 water type, and especially, arsenic and boron concentrations reached levels as high as 3 and 127 mg/L, respectively. The concentrations of arsenic and boron in the geothermal fluid and groundwater exceeded the maximum allowable limits given in the national and international standards for drinking water quality. According to temporally monitored results, geothermal fluid has extremely high mineral content which influenced the quality of groundwater resources of the area where water resource is commonly used for agricultural irrigation.
  • Conference Object
    Citation - Scopus: 4
    High Arsenic Levels in Groundwater Resources of Gediz Graben, Western Turkey
    (CRC Press, 2016) Baba, Alper; Baba, Alper; Gündüz, Orhan; Elçi, Alper; Sözbilir, Hasan; Murathan, Alim; 03.07. Department of Environmental Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Gediz Graben situated in western Turkey is an area containing extensional structures with active tectonics and geothermal systems that serves as a suitable environment for the presence of high levels of arsenic (As) in groundwater. The results of a comprehensive monitoring program in the basin revealed that the maximum As concentration detected during the monitoring program was 3086 ppb and the average value was calculated to be 23.63 ppb. In addition, As levels in 28% of the water samples were above the 10 ppb limit value making them unsuitable for drinking water supply. These high As concentrations in the basin was mostly associated with long detention times of water in altered rocks located along detachment faults, strong water–rock interaction processes in the alteration zones and anthropogenic influences made within the geothermal fluid reservoir. © 2016 Taylor & Francis Group, London.
  • Article
    Citation - WoS: 27
    Citation - Scopus: 31
    Statistical Analysis of Causes of Death (2005-2010) in Villages of Simav Plain, Turkey, With High Arsenic Levels in Drinking Water Supplie
    (Taylor and Francis Ltd., 2015) Baba, Alper; Bakar, Coşkun; Gündüz, Orhan; Baba, Alper; Elçi, Alper; Gürleyük, Hakan; Mutlu, Merdiye; Çakır, Ayşe; 03.07. Department of Environmental Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    The purpose of this research was to compare the causes of death in 5 villages situated in Simav Plain, Turkey, during 2005-2010 where different arsenic levels were detected in drinking water supplies. Since groundwater in Simav Plain had arsenic concentrations that ranged between 7.1 and 833.9 ppb, a two-phase research was formulated. In the first phase, public health surveys were conducted with 1,003 villagers to determine the distribution of diseases. In the second phase, verbal autopsy surveys and official death records were used to investigate the causes of death. In total, 402 death cases were found in the study area where cardiovascular system diseases (44%) and cancers (15.2%) were major causes. Cancers of lung (44.3%), prostate (9.8%), colon (9.8%), and stomach (8.2%) were comparably higher in villages with high arsenic levels in drinking water supplies. Furthermore, the majority of cases of liver, bladder, and stomach cancers were observed in villages with high arsenic levels. © 2015 Taylor and Francis Group, LLC.
  • Article
    Citation - WoS: 2
    Citation - Scopus: 2
    Sample Collection Into Sterile Vacuum Tubes To Preserve Arsenic Speciation in Natural Water Samples
    (American Society of Civil Engineers (ASCE), 2013) Baba, Alper; Gürleyük, Hakan; Gündüz, Orhan; Elçi, Alper; Baba, Alper; Şimşek, Celalettin; 03.07. Department of Environmental Engineering; 03.03. Department of Civil Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    The accurate speciation analysis of arsenic is a serious concern for water quality monitoring programs. Because the preservation of sample integrity until analysis is one of the most important aspects of speciation, this study aims to compare the performance of four different sample preservation methods under diverse conditions of sample quality. Natural samples with different characteristics were collected into the following containers to study their effectiveness: (1) standard high-density polyethylene bottle with no preservative; (2) empty, sterile Vacuette tube with no preservative; (3) sterile tripotassium ethylenediaminetetraacetic acid (K3EDTA) Vacuette tube with K3EDTA additive; and (4) empty, sterile Vacuette tube with added hydrochloric acid (HCl). Known concentrations of arsenite [As(III)] were also added to each container to monitor the oxidation of As(III) to arsenate [As(V)]. The results revealed recovery ratios exceeding 95% in all containers with sterile vacuum conditions. In particular, the K3EDTA Vacuette tube yielded a recovery very close to 100% of the spiked As(III), which is known to rapidly oxidize to As(V). Overall, collecting the sample into a container under sterile vacuum conditions and using a universally accepted preserving agent such as EDTA or HCl significantly improved the preservation of the original species distribution in the water matrix studied, compared to sampling without the use of preservation methods. After validation by future research, these sterile vacuum tubes can possibly be utilized for collecting and storing samples for the routine speciation analysis of other elements such as selenium, chromium, and antimony.