Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7755

Browse

Search Results

Now showing 1 - 5 of 5
  • Article
    Citation - WoS: 15
    Citation - Scopus: 19
    Brominated Flame Retardants in a Computer Technical Service: Indoor Air Gas Phase, Submicron (pm1) and Coarse (pm10) Particles, Associated Inhalation Exposure, and Settled Dust
    (Elsevier Ltd., 2019) Genişoğlu, Mesut; Sofuoğlu, Aysun; Kurt Karakuş, Perihan Binnur; Birgül, Aşkın; Sofuoğlu, Sait Cemil; Sofuoğlu, Aysun; 03.02. Department of Chemical Engineering; 03.07. Department of Environmental Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Brominated flame retardants (BFRs) are found in multi-media indoors, therefore, may pose serious risks to human health. This study investigated the occurrence of BFRs in particulate matter (PM1 and PM10) and gas phase by active and passive sampling, and settled dust to estimate potential exposure in a computer technical service. Polybrominated diphenyl ethers (PBDEs) and their alternatives (novel BFRs, NBFRs) were studied. PM and gas phase were collected on glass fiber filters and polyurethane foam plugs, respectively, and analyzed with a GC/MS after extraction, clean-up, and concentration. Inhalation exposure of the staff was estimated based on the measured concentrations using Monte Carlo simulation. BDE-209 was the dominating PBDE congener in all media while bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate and 1,2-bis(2,4,6-tribromophenoxy)ethane were those of NBFRs. Submicron particulate matter (PM1) BFR levels constituted about one half of the PM10-associated concentrations, while average PM10 mass concentration (69.9 μg m−3) was nine times that of PM1 (7.73 μg m−3). Calculated log10 dust-gas and PM-gas partitioning coefficients ranged from −5.03 to −2.10, −2.21 to −0.55, and −2.26 to −1.04 for settled dust, PM10, and PM1, respectively. The indoor/outdoor concentration ratios were >1 for all compounds indicating the strength of indoor sources in the service. The estimated potential inhalation exposures, for future chronic-toxic and carcinogenic risk assessments, indicated that the levels of gas-phase and PM1-associated exposures were similar at approximately one half of PM10-associated levels. Results of this study indicate that the occurrence of BFRs in all studied media should be taken into consideration for occupational health mitigation efforts.
  • Article
    Citation - WoS: 98
    Citation - Scopus: 118
    Organophosphate Ester (opes) Flame Retardants and Plasticizers in Air and Soil From a Highly Industrialized City in Turkey
    (Elsevier Ltd., 2018) Kurt Karakuş, Perihan Binnur; Alegria, Henry; Birgül, Aşkın; Güngörmüş, Elif; Jantunen, Liisa; 01. Izmir Institute of Technology
    Passive air samples were collected at eight sites in Bursa, Turkey during five sampling periods between February–December 2014. Locations encompassed urban, suburban, industrial, rural and background environments. Soil samples (n = 8) were collected at each site during February 2014. Six OPEs were detected in samples: tris(2-chloroethyl) phosphate (TCEP), tris(chloropropyl) phosphate (TCPP), triphenyl phosphate (TPHP), tris(2-butoxyethyl) phosphate (TBOEP), tris(2-ethylhexyl) phosphate (TEHP), and tris(2-isopropylphenyl) phosphate (T2iPPP). Frequency of detection in air samples was TCPP and TPHP (100%) > TBOEP (88%) > TCEP (85%) > TEHP (78%) > T2iPPP (20%). Total OPEs in air per site by sampling period (excluding non-detects) ranged from 529 to 19,139 pg/m3. In soil, total OPEs ranged from 38 to 468 ng/g dw. In air, alkylated OPEs dominated followed by halogenated and aryl OPEs. In air, annual mean concentrations were TBOEP > TCPP > TPHP > T2iPPP > TEHP > TCEP. In soils, alkylated OPEs were dominant at six sites and chlorinated OPEs at two sites. A comparison of OPE profiles between air and soil suggests that soils may be partly a source of OPEs to air. Mean concentrations in air were not directly proportional to temperature, and there were differences between alkylated compared to halogenated and aryl OPEs. In air, total and alkylated OPEs levels were fairly uniform, whereas more variability was found for the halogenated and aryl compounds. The relative contribution to total OPEs decreases for alkylated OPEs and increases for halogenated OPEs in samples going from background to suburban to urban and industrial sites. Levels of individual OPEs were all positively correlated between air and soils. In air, correlations between individual compounds were weak to moderate and were only statistically significant for TBOEP and TPHP. In soils, correlations were generally stronger and statistically significant only for TPHP and T2iPPP.
  • Article
    Citation - WoS: 45
    Citation - Scopus: 45
    The First Countrywide Monitoring of Selected Pops: Polychlorinated Biphenyls (pcbs), Polybrominated Diphenyl Ethers (pbdes) and Selected Organochlorine Pesticides (ocps) in the Atmosphere of Turkey
    (Elsevier Ltd., 2018) Kurt Karakuş, Perihan Binnur; Ugranlı Çiçek, Tuğba; Sofuoğlu, Sait Cemil; Çelik, Halil; Güngörmüş, Elif; Ökten, Hatice Eser; Sofuoğlu, Aysun; Sofuoğlu, Aysun; Birgül, Aşkın; Alegria, Henry; Jones, Kevin C.; 03.07. Department of Environmental Engineering; 03.02. Department of Chemical Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    Atmospheric levels of 43 PCBs, 22 OCPs, and 14 PBDEs were determined in 16 cities at urban and rural sites by passive sampling to generate the first large-scale nationwide dataset of POP residues in Turkey's atmosphere. Sampling campaign was performed from May 2014 to April 2015 with three-month sampling periods at locations on east-west and north-south transects through the country to investigate seasonal and spatial variations, including long range atmospheric transport (LRAT). Factor analysis was conducted to infer on the potential sources. Overall average Σ43PCBs concentration was 108 ± 132 pg/m3. PCB-118 (26.3 ± 44.6 pg/m3) was the top congener, and penta-CBs had the highest contribution with 54.3%. ΣDDTs had the highest annual mean concentration with 134 ± 296 pg/m3 among the OCP groups among which the highest concentration compound was p'p-DDE (97.6 ± 236 pg/m3). Overall average concentration of Σ14PBDEs was 191 ± 329 pg/m3 with the highest contribution from BDE-190 (42%). Comparison of OCPs and PCBs concentrations detected at temperatures which were above and below annual average temperature indicated higher concentrations in the warmer periods, hence significance of secondary emissions for several OCPs and Σ43PCBs, as well as inference as LRAT from secondary emissions. The first nationwide POPs database constructed in this study, point to current use, local secondary emissions, and LRAT for different individual compounds, and indicate the need for regular monitoring. The first country-wide passive sampling of selected POPs showed no unequivocal trends reflecting transitional location of Turkey.
  • Article
    Citation - WoS: 39
    Citation - Scopus: 44
    Polyurethane Foam (puf) Disk Passive Samplers Derived Polychlorinated Biphenyls (pcbs) Concentrations in the Ambient Air of Bursa-Turkey: Spatial and Temporal Variations and Health Risk Assessment
    (Elsevier Ltd., 2017) Birgül, Aşkın; Kurt Karakuş, Perihan Binnur; Alegria, Henry; Güngörmüş, Elif; Çelik, Halil; Çiçek, Tuğba; Güven, Emine Can; 01. Izmir Institute of Technology
    Polyurethane foam (PUF) passive samplers were employed to assess air concentrations of polychlorinated biphenyls (PCBs) in background, agricultural, semi-urban, urban and industrial sites in Bursa, Turkey. Samplers were deployed for approximately 2-month periods from February to December 2014 in five sampling campaign. Results showed a clear rural-agricultural-semi-urban-urban-industrial PCBs concentration gradient. Considering all sampling periods, ambient air concentrations of Σ43PCBs ranged from 9.6 to 1240 pg/m3at all sites with an average of 24.1 ± 8.2, 43.8 ± 24.4, 140 ± 190, 42.8 ± 24.6, 160 ± 280, 84.1 ± 105, 170 ± 150 and 280 ± 540 pg/m3for Mount Uludag, Uludag University Campus, Camlica, Bursa Technical University Osmangazi Campus, Hamitler, Agakoy, Kestel Organised Industrial District and Demirtas Organised Industrial District sampling sites, respectively. The ambient air PCB concentrations increased along a gradient from background to industrial areas by a factor of 1.7–11.4. 4-Cl PCBs (31.50–81.60%) was the most dominant homologue group at all sampling sites followed by 3-Cl, 7-Cl, 6-Cl and 5-Cl homologue groups. Sampling locations and potential sources grouped in principal component analysis. Results of PCA plots highlighted a large variability of the PCB mixture in air, hence possible related sources, in Bursa area. Calculated inhalation risk levels in this study indicated no serious adverse health effects. This study is one of few efforts to characterize PCB composition in ambient air seasonally and spatially for urban and industrial areas of Turkey by using passive samplers as an alternative sampling method for concurrent monitoring at multiple sites.
  • Master Thesis
    Persistent Organic Pollutants in Turkey's Atmosphere: Spatial Variation
    (Izmir Institute of Technology, 2015) Çiçek, Tuğba; Sofuoğlu, Sait Cemil; Sofuoğlu, Sait Cemil; Kurt Karakuş, Perihan Binnur; 03.07. Department of Environmental Engineering; 03. Faculty of Engineering; 01. Izmir Institute of Technology
    The objectives of this study was to measure ambient air levels of 43 PCBs and 22 OCPs in 16 cities at urban and background sites by using polyurethane foam discs (PUF) as passive air samplers (PAS), to investigate spatial variations, and to generate a baseline database which is the first large-scale nationwide database for POP residues in air of Turkey. Air sampling was conducted from May 2014 to April 2015 with three-month sampling periods. Samples were analyzed by gas chromatography - mass spectrometry after extraction, clean-up, and volume reduction. The one-year overall average Σ43PCBs concentration was 108±132 pg/m3. The one-year average of Σ43PCBs ranged from 14.5±14.3 pg/m3 (Kayseri) to 403±428 pg/m3 (İzmir) at urban sites with a mean of 116±141 pg/m3, and from 19.0±22.7 pg/m3 (Aksaray) to 217±353 pg/m3 (Kastamonu) at rural sites with a mean of 101±122 pg/m3. PCB 118 had the highest mean concentration (26.3±44.6 pg/m3) among the 43 PCB congeners. The PCB homologue group with the highest contribution was penta-CBs with 54.3%. Overall one-year average Σ22OCPs concentration was 341±870 pg/m3 with a range of 55.3±36.5 pg/m3 (Çankırı) and 1294±2153 pg/m3 (Kırklareli). ΣDDT had the highest overall mean level with 134±296 pg/m3 among the OCP groups. The highest concentration OCPs were p’p-DDE (97.6±236 pg/m3), HCB (45.3±197 pg/m3), α-HCH (22.0±92.8 pg/m3), β-HCH (21.8±96.1 pg/m3), and p’p-DDT (21.3±77.4 pg/m3). Principle Components Analysis showed that, in addition to the OCP with the highest concentration (p’p-DDE), parent OCP compounds such as α-endosulfan, α-HCH, HCB, and p’p-DDT differed from the others, and some of the remaining decay products were grouped together indicating similar behavior. Highly chlorinated PCBs were clustered together. Mann-Whitney U test indicated that the difference in the median concentrations of urban and rural sites was not significant. It was also used to test the significance of temperature effect on the median concentrations at a high and a low temperature range. The medians were significantly different for HCB, dieldrin, p’p-DDT, and β-endosulfan at urban sites but not significant for the remaining OCPs and ΣPCBs. The difference in the medians was significant for HCB, heptachlor, dieldrin, endrin, p’p-DDE, Mirex, and ΣPCBs at rural sites