Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection
Permanent URI for this collectionhttps://hdl.handle.net/11147/7755
Browse
3 results
Search Results
Now showing 1 - 3 of 3
Article Citation - WoS: 40Citation - Scopus: 44Experimental and Numerical Investigation of Forced Convection in a Double Skin Façade by Using Nodal Network Approach for Istanbul(Elsevier Ltd., 2019) İnan, Tuğba; Başaran, TahsinIn this study, temperature distribution and heat transfer through the cavity of a double skin façade (DSF) was investigated in the laboratory environment and analyzed numerically by using nodal network approach. The verification of the nodal network method was conducted by using data from the steady-state experiments and the same method was applied for the climate of Istanbul, Turkey under unsteady outside boundary conditions. Furthermore, heat gain and loss values in DSF for January and July were calculated and compared with single skin façade (SSF) application for different directions of the façades. The results were given for a day and a working time period of the office buildings by using monthly average daily climate data. Distinction working hours were more convenient to investigate the energy performance of DSF because of solar radiation effect. Using DSF in all directions, the cooling loads decreased up to 26% comparing to the SSF. DSF system was disadvantageous comparing to the SSF for January. However, it was shown that the heated air in the cavity could be used for preheating process of air in a HVAC system for winter period.Article Citation - WoS: 18Citation - Scopus: 21Experimental and Numerical Investigation of Forced Convection in a Double Skin Façade(MDPI Multidisciplinary Digital Publishing Institute, 2017) İnan, Tuğba; Başaran, Tahsin; Erek, AytunçFlow and heat transfer of the air cavity between two glass façades designed in the box window type of double skin façade (DSF) was evaluated in a test room which was set up for measurements in the laboratory environment and analyzed under different working conditions by using a computational fluid dynamics tool. Using data from the experimental studies, the verification of the numerical studies was conducted and the air flow and heat transfer in the cavity between the two glass façades were examined numerically in detail. The depth to height of the cavity, the aspect ratio, was changed between 0.10 and 0.16, and was studied for three different flow velocities. Reynolds and average Nusselt numbers ranging from 28,000 to 56,500 and 134 to 272, respectively, were calculated and a non-dimensional correlation between Reynolds and Nusselt numbers was constructed to evaluate the heat transfer from the cavity (except inlet and outlet sections) air to the inside environment and it could be used the box window type of DSF applications having relatively short cavities.Article Citation - WoS: 23Citation - Scopus: 28Thermal Analysis of the Domed Vernacular Houses of Harran, Turkey(SAGE Publications Inc., 2011) Başaran, TahsinMinimum energy consumption and economic efficiency using local and recyclable materials is essential for achieving sustainability, considering the depletion of global energy sources. The Anatolian Peninsula presents a diverse range of local building construction techniques accumulated over centuries, which meet the criteria mentioned above. Due to richness of climatic variety and the influence of many civilisations throughout history, Anatolian regions reflect this richness in their respective solutions to building construction. Built mainly out of brick and stone, mortared and plastered by mud, the domed vernacular houses of Harran, a small town in the province of Urfa in the hot arid climate of southeastern Anatolia, are one of the best examples that deserve attention with respect to minimum energy consumption. In this study, the thermal performance of the "Harran house" as a vernacular type was analysed. For this purpose, temperatures inside and outside a Harran house complex with relative humidity variations were measured. In addition, for investigating the domed houses' thermal behaviour, temperature measurements at different surfaces and media were recorded. The solar chimney effect obtained from the dome and the importance of the thermal mass of the square base of the house were also evaluated. The study yielded results, which showed that the indoor conditions were within the limits for thermal comfort even under extreme summer conditions.
