Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7755

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 20
    Citation - Scopus: 26
    Pops in a Major Conurbation in Turkey: Ambient Air Concentrations, Seasonal Variation, Inhalation and Dermal Exposure, and Associated Carcinogenic Risks
    (Springer Verlag, 2016) Ugranlı, Tuğba; Güngörmüş, Elif; Kavcar, Pınar; Demircioğlu, Eylem; Odabaşı, Mustafa; Sofuoğlu, Sait Cemil; Lammel, Gerhard; Sofuoglu, Aysun
    Semi-volatile organic compounds were monitored over a whole year, by collection of gas and particle phases every sixth day at a suburban site in Izmir, Turkey. Annual mean concentrations of 32 polychlorinated biphenyls (∑32PCBs) and 14 polycyclic aromatic hydrocarbons (∑14PAHs) were 348 pg/m3 and 36 ng/m3, respectively, while it was 273 pg/m3 for endosulfan, the dominant compound among 23 organochlorine pesticides (OCPs). Monte Carlo simulation was applied to the USEPA exposure-risk models for the estimation of the population exposure and carcinogenic risk probability distributions for heating and non-heating periods. The estimated population risks associated with dermal contact and inhalation routes to ∑32PCBs, ∑14PAHs, and some of the targeted OCPs (α-hexachlorocyclohexane (α-HCH), β-hexachlorocyclohexane (β-HCH), heptachlor, heptachlor epoxide, α-chlordane (α-CHL), γ-chlordane (γ-CHL), and p,p′-dichlorodiphenyltrichloroethane (p,p′-DDT)) were in the ranges of 1.86 × 10−16–7.29 × 10−9 and 1.38 × 10−10–4.07 × 10−6, respectively. The inhalation 95th percentile risks for ∑32PCBs, ∑14PAHs, and OCPs were about 6, 3, and 4–7 orders of magnitude higher than those of dermal route, respectively. The 95th percentile inhalation risk for ∑32PCBs and OCPs in the non-heating period were 1.8- and 1.2–4.6 folds higher than in the heating period, respectively. In contrast, the 95th percentile risk levels for ∑14PAHs in the heating period were 4.3 times greater than that of non-heating period for inhalation, respectively. While risk levels associated with exposure to PCBs and OCPs did not exceed the acceptable level of 1 × 10−6, it was exceeded for 47 % of the population associated with inhalation of PAHs with a maximum value of about 4 × 10−6.
  • Article
    Citation - WoS: 21
    Citation - Scopus: 26
    Indoor Environmental Quality in Chemistry and Chemical Engineering Laboratories at Izmir Institute of Technology
    (Turkish National Committee for Air Pollution Research (TUNCAP), 2015) Ugranlı, Tuğba; Toprak, Melis; Gürsoy, Gül; Çimrin, Arif H.; Sofuoğlu, Sait Cemil
    Indoor air pollution in university research laboratories may be important to building occupants, especially for those who work in the laboratories. In this study, indoor air quality (IAQ) and indoor environmental comfort were investigated in research laboratories of two departments at a university. PM2.5, PM10, TVOC (total volatile organic compounds), and CO concentrations, and three comfort variables which are temperature, relative humidity, and CO2 were measured. PM2.5 concentration was determined gravimetrically by collecting particles on glass fiber filters, whereas the remaining pollutants and comfort variables were measured using a monitoring device. IAQ measurements showed that levels of all pollutants were under the limits in both of the departments except for TVOC in one laboratory which had a mean concentration of 182 ppb. The comfort variables were in the comfort ranges for laboratories in both of the departments except for temperature in one laboratory with a mean value of 30 °C. In conclusion, measures are needed for extensive uses of organic solvents because ventilation may not be sufficient to keep VOC concentrations within the limits, and to provide thermal comfort.