PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7645

Browse

Search Results

Now showing 1 - 6 of 6
  • Article
    Citation - WoS: 4
    Citation - Scopus: 4
    Colorimetric Assaying of Exosomal Metabolic Biomarkers
    (MDPI, 2023) Yan, Evelias; Goyal, Garima; Yıldız, Ümit Hakan; Boehm, Bernhard O.; Palaniappan, Alagappan
    Exosomes released into the extracellular matrix have been reported to contain metabolic biomarkers of various diseases. These intraluminal vesicles are typically found in blood, urine, saliva, breast milk, cerebrospinal fluid, semen, amniotic fluid, and ascites. Analysis of exosomal content with specific profiles of DNA, microRNA, proteins, and lipids can mirror their cellular origin and physiological state. Therefore, exosomal cargos may reflect the physiological processes at cellular level and can potentially be used as biomarkers. Herein, we report an optical detection method for assaying exosomal biomarkers that supersedes the state-of-the-art time consuming and laborious assays such as ELISA and NTA. The proposed assay monitors the changes in optical properties of poly(3-(4-methyl-3'-thienyloxy) propyltriethylammonium bromide) upon interacting with aptamers/peptide nucleic acids in the presence or absence of target biomarkers. As a proof of concept, this study demonstrates facile assaying of microRNA, DNA, and advanced glycation end products in exosomes isolated from human plasma with detection levels of ~1.2, 0.04, and 0.35 fM/exosome, respectively. Thus, the obtained results illustrate that the proposed methodology is applicable for rapid and facile detection of generic exosomal biomarkers for facilitating diseases diagnosis.
  • Article
    Citation - WoS: 6
    Citation - Scopus: 5
    Charmm Force Field Generation for a Cationic Thiophene Oligomer With Fftk
    (Springer, 2021) Kıbrıs, Erman; Nalıncı Barbak, Nehir; Elmacı Irmak, Nuran
    In the present work, CHARMM force field parameters are generated for a cationic oligomer of N, N, N-trimethyl-3-(4-methylthiophen-3-yl) oxy) propan-1-aminium) which has the potential for sensing biological molecules such as nucleic acids, nucleobases. We have used ffTK (force field tool kit) to obtain potential parameters. MD simulations are performed for 20-mer and its complexes with AMP and ATP. The simulation results are analyzed to see the number of phosphates in adenosine nucleotides effects on the structure of the backbone of oligomer. The UV-VIS calculations for the conformers which possess the most probable radius of gyration are carried out and compared to the experimental ones to validate the generated force field. Recent studies have shown that, biologically important anions (ATP, AMP, vb.) change the spectroscopic properties of cationic polythiophenes (CPT) in the solutions. This work aims to generate CHARMM compatible force field parameters for a CPT to explain experimental studies. The type of interactions will be investigated deeply to lead new biosensor studies by examining the formation and the structure of complexes that consist of a oligothiophene and biological molecules, ATP, AMP by molecular dynamic simulations.
  • Article
    Citation - WoS: 39
    Citation - Scopus: 37
    Flow-Through Colorimetric Assay for Detection of Nucleic Acids in Plasma
    (Elsevier, 2019) Ammanath, Gopal; Yeasmi, Sanjida; Srinivasulu, Yuvasri; Vats, Mukti; Cheema, Jamal Ahmed; Nabilah, Fairuz; Liedberg, Bo; Yıldız, Ümit Hakan
    A flow-through colorimetric assay for detection of nucleic acids in plasma is reported. The proposed assay features an array of four polyvinylidene fluoride (PVDF) membranes impregnated with cationic poly (3-alkoxy-4-methylthiophene) (PT) as an optical reporter. The sensing strategy is based on monitoring the changes in optical properties of PT, upon complexation with target nucleic acids in the presence and in the absence of their corresponding complementary peptide nucleic acids (PNAs). As a proof of concept, the proposed methodology is validated using two biomarkers; lung cancer associated microRNA (mir21) and hepatitis B virus DNA (HBV-DNA). The flow-through colorimetric assay enabled detection of mir21 and HBV-DNA in plasma without requiring tedious sample pre-treatment and clean up protocols. Colorimetric responses for mir21 and HBV-DNA were obtained at nanomolar concentrations over five orders of magnitudes (from 1 nM to 10 mu M), with a limit of detection of -0.6 nM and -2 nM in DI water and plasma, respectively. A logic gate system was developed to utilize the colorimetric assay responses as inputs for discrimination of mir21 and HBV-DNA and subsequently to obtain a profile of nucleic acids in samples that exceed respective clinical threshold limits, thereby enabling rapid and point of care (POC) disease diagnosis. Furthermore, the proposed methodology can be utilized for detection of a large number of nucleic acids in plasma by extending the array of PT impregnated membranes incorporated with their corresponding complementary PNAs. (C) 2019 Elsevier B.V. All rights reserved.
  • Article
    Citation - WoS: 32
    Citation - Scopus: 32
    Luminescent Device for the Detection of Oxidative Stress Biomarkers in Artificial Urine
    (American Chemical Society, 2018) Ammanath, Gopal; Yıldız, Ümit Hakan; Palaniappan, Alagappan; Liedberg, Bo
    A luminescent paper-based device for the visual detection of oxidative stress biomarkers is reported. The device consists of a polyvinylidene fluoride membrane impregnated with poly(3-alkoxy-4-methylthiophene) (PT) for colorimetric detection. 8-hydroxy-2′-deoxyguanosine (8-OHdG), a biomarker associated with oxidative stress, is used as a model system for validating the proposed methodology. The detection strategy is based on monitoring the changes in optical properties of PT associated with its conformational changes upon interaction with an aptamer in the presence and in the absence of 8-OHdG. Fluorometric and colorimetric monitoring revealed linear responses for 8-OHdG concentrations between 50 pM and 500 nM (∼14 pg/mL to 140 ng/mL), with limits of detection of ∼300 pM and ∼350 pM, respectively for (n = 3). Colorimetric responses in artificial urine ascertained rapid, sensitive, and selective detection of 8-OHdG at clinically relevant (pM to nM) concentration levels. Furthermore, the proposed methodology enables point-of-care diagnostics for oxidative stress without requiring sophisticated instrumentation.
  • Article
    Citation - WoS: 24
    Citation - Scopus: 23
    Tailoring Conformation-Induced Chromism of Polythiophene Copolymers for Nucleic Acid Assay at Resource Limited Settings
    (American Chemical Society, 2016) Rajwar, Deepa; Ammanath, Gopal; Cheema, Jamal Ahmed; Palaniappan, Alagappan; Yıldız, Ümit Hakan; Liedberg, Bo
    Here we report on the design and synthesis of cationic water-soluble thiophene copolymers as reporters for colorimetric detection of microRNA (miRNA) in human plasma. Poly(3-alkoxythiophene) (PT) polyelectrolytes with controlled ratios of pendant groups such as triethylamine/1-methyl imidazole were synthesized for optimizing interaction with target miRNA sequence (Tseq). Incorporation of specific peptide nucleic acid (PNA) sequences with the cationic polythiophenes yielded distinguishable responses upon formation of fluorescent PT-PNA-Tseq triplex and weakly fluorescent PT-Tseq duplex, thereby enabling selective detection of target miRNA. Unlike homopolymers of PT (hPT), experimental results indicate the possibility of utilizing copolymers of PT (cPT) with appropriate ratios of pendant groups for miRNA assay in complex matrices such as plasma. As an illustration, colorimetric responses were obtained for lung cancer associated miRNA sequence (mir21) in human plasma, with a detection limit of 10 nM, illustrating the feasibility of proposed methodology for clinical applications without involving sophisticated instrumentation. The described methodology therefore possesses high potential for low-cost nucleic acid assays in resource-limited settings.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 14
    Polythiophene Derivative on Quartz Resonators for Mirna Capture and Assay
    (Royal Society of Chemistry, 2015) Palaniappan, Al.; Cheema, Jamal Ahmed; Rajwar, Deepa; Ammanath, Gopal; Xiaohu, Liu; Seng Koon, Lim; Yi, Wang; Yıldız, Ümit Hakan; Liedberg, Bo
    A novel approach for miRNA assay using a cationic polythiophene derivative, poly[3-(3′-N,N,N-triethylamino-1′-propyloxy)-4-methyl-2,5-thiophene hydrobromide] (PT), immobilized on a quartz resonator is proposed. The cationic PT enables capturing of all RNA sequences in the sample matrix via electrostatic interactions, resulting in the formation of PT-RNA duplex structures on quartz resonators. Biotinylated peptide nucleic acid (b-PNA) sequences are subsequently utilized for the RNA assay, upon monitoring the PT-RNA-b-PNA triplex formation. Signal amplification is achieved by anchoring avidin coated nanoparticles to b-PNA in order to yield responses at clinically relevant concentration regimes. Unlike conventional nucleic acid assay methodologies that usually quantify a specific sequence of RNA, the proposed approach enables the assay of any RNA sequence in the sample matrix upon hybridization with a PNA sequence complementary to the RNA of interest. As an illustration, successful detection of mir21, (a miRNA sequence associated with lung cancer) is demonstrated with a limit of detection of 400 pM. Furthermore, precise quantification of mir21 in plasma samples is demonstrated without requiring PCR and sophisticated instrumentation.