Food Engineering / Gıda Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/12

Browse

Search Results

Now showing 1 - 5 of 5
  • Review
    Citation - WoS: 41
    Citation - Scopus: 43
    Electrochemical Sensors in the Food Sector: a Review
    (American Chemical Society, 2024) Ghaani, Masoud; Azimzadeh, Mostafa; Büyüktaş, Duygu; Carullo, Daniele; Farris, Stefano
    In a world that is becoming increasingly concerned with health, safety, and the sustainability of food supply chains, the control and assurance of food quality have become of utmost importance. This review examines the application and potential of electrochemical sensors in the dynamic field of food science to meet these expanding demands. The article introduces electrochemical sensors and describes their operational mechanics and the components contributing to their function. A summary of the most prevalent electrochemical methods outlines the diverse food analysis techniques available. The review shifts to discussing the food science applications of these sensors, highlighting their crucial role in detecting compounds in food samples like meat, fish, juice, and milk for contemporary quality control. This paper showcases electrochemical sensors' utility in food analysis, underscoring their significance as powerful, efficient tools for maintaining food safety and how they could transform our approach to global food quality control and assurance.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 9
    A Screen-Printed Electrode Modified With Gold Nanoparticles/ Cellulose Nanocrystals for Electrochemical Detection of 4,4'-methylene Diphenyl Diamine
    (Elsevier, 2023) Büyüktaş, Duygu; Ghaani, Masoud; Rovera, Cesare; Carullo, Daniele; Olsson, Richard T.; Korel, Figen; Farris, Stefano
    Developing simple, cost-effective, easy-to-use, and reliable analytical devices if of utmost importance for the food industry for rapid in-line checks of their products that must comply with the provisions set by the current legislation. The purpose of this study was to develop a new electrochemical sensor for the food packaging sector. More specifically, we propose a screen -printed electrode (SPE) modified with cellulose nanocrystals (CNCs) and gold nanoparticles (AuNPs) for the quantification of 4,4'-methylene diphenyl diamine (MDA), which is one of the most important PAAs that can transfer from food packaging materials into food stuffs. The electrochemical performance of the proposed sensor (AuNPs/CNCs/SPE) in the presence of 4,4'- MDA was evaluated using cyclic voltammetry (CV). The modified AuNPs/CNCs/SPE showed the highest sensitivity for 4,4'-MDA detection, with a peak current of 9.81 mu A compared with 7.08 mu A for the bare SPE. The highest sensitivity for 4,4'-MDA oxidation was observed at pH = 7, whereas the detection limit was found at 57 nM and the current response of 4,4'-MDA rose linearly as its concentration increased from 0.12 mu M to 100 mu M. Experiments using real packaging materials revealed that employing nanoparticles dramatically improved both the sensitivity and the selectivity of the sensor, which can be thus considered as a new analytical tool for quick, simple, and accurate measurement of 4,4 '-MDA during converting operations.
  • Article
    Citation - WoS: 9
    Citation - Scopus: 8
    Development of a New Electrochemical Sensor Based on Molecularly Imprinted Biopolymer for Determination of 4,4'-methylene Diphenyl Diamine
    (MDPI, 2023) Ghaani, Masoud; Büyüktaş, Duygu; Carullo, Daniele; Farris, Stefano
    A new molecularly imprinted electrochemical sensor was proposed to determine 4,4' methylene diphenyl diamine (MDA) using molecularly imprinted polymer-multiwalled carbon nanotubes modified glassy carbon electrode (MIP/MWCNTs/GCE). GCE was coated by MWCNTs (MWCNTs/GCE) because of their antifouling qualities and in order to improve the sensor sensitivity. To make the whole sensor, a polymeric film made up of chitosan nanoparticles was electrodeposited by the cyclic voltammetry method on the surface of MWCNTs/GCE in the presence of MDA as a template. Different parameters such as scan cycles, elution time, incubation time, molar ratio of template molecules to functional monomers, and pH were optimized to increase the performance of the MIP sensor. With a detection limit of 15 nM, a linear response to MDA was seen in the concentration range of 0.5-100 mu M. The imprinting factor (IF) of the proposed sensor was also calculated at around 3.66, demonstrating the extremely high recognition performance of a MIP/MWCNT-modified electrode. Moreover, the sensor exhibited good reproducibility and selectivity. Finally, the proposed sensor was efficiently used to determine MDA in real samples with satisfactory recoveries ranging from 94.10% to 106.76%.
  • Article
    Citation - WoS: 19
    Citation - Scopus: 20
    Transparent Pullulan/Mica Nanocomposite Coatings With Outstanding Oxygen Barrier Properties
    (MDPI Multidisciplinary Digital Publishing Institute, 2017) Uysal Ünalan, İlke; Boyacı, Derya; Trabattoni, Silvia; Tavazzi, Silvia; Farris, Stefano
    This study presents a new bionanocomposite coating on poly(ethylene terephthalate) (PET) made of pullulan and synthetic mica. Mica nanolayers have a very high aspect ratio (α), at levels much greater than that of conventional exfoliated clay layers (e.g., montmorillonite). A very small amount of mica (0.02 wt %, which is φ ≈ 0.00008) in pullulan coatings dramatically improved the oxygen barrier performance of the nanocomposite films under dry conditions, however, this performance was partly lost as the environmental relative humidity (RH) increased. This outcome was explained in terms of the perturbation of the spatial ordering of mica sheets within the main pullulan phase, because of RH fluctuations. This was confirmed by modelling of the experimental oxygen transmission rate (OTR) data according to Cussler’s model. The presence of the synthetic nanobuilding block (NBB) led to a decrease in both static and kinetic coefficients of friction, compared with neat PET (≈12% and 23%, respectively) and PET coated with unloaded pullulan (≈26% reduction in both coefficients). In spite of the presence of the filler, all of the coating formulations did not significantly impair the overall optical properties of the final material, which exhibited haze values below 3% and transmittance above 85%. The only exception to this was represented by the formulation with the highest loading of mica (1.5 wt %, which is φ ≈ 0.01). These findings revealed, for the first time, the potential of the NBB mica to produce nanocomposite coatings in combination with biopolymers for the generation of new functional features, such as transparent high oxygen barrier materials.
  • Article
    Citation - WoS: 24
    Citation - Scopus: 23
    Graphene Oxide Bionanocomposite Coatings With High Oxygen Barrier Properties
    (MDPI Multidisciplinary Digital Publishing Institute, 2016) Uysal Ünalan, İlke; Boyacı, Derya; Ghaani, Masoud; Trabattoni, Silvia; Farris, Stefano
    In this work, we present the development of bionanocomposite coatings on poly(ethylene terephthalate) (PET) with outstanding oxygen barrier properties. Pullulan and graphene oxide (GO) were used as main polymer phase and nanobuilding block (NBB), respectively. The oxygen barrier performance was investigated at different filler volume fractions (φ) and as a function of different relative humidity (RH) values. Noticeably, the impermeable nature of GO was reflected under dry conditions, in which an oxygen transmission rate (OTR, mL m-2 24 h-1) value below the detection limit of the instrument (0.01 mL m-2 24 h-1) was recorded, even for ' as low as 0.0004. A dramatic increase of the OTR values occurred in humid conditions, such that the barrier performance was totally lost at 90% RH (the OTR of coated PET films was equal to the OTR of bare PET films). Modelling of the experimental OTR data by Cussler’s model suggested that the spatial ordering of GO sheets within the main pullulan phase was perturbed because of RH fluctuations. In spite of the presence of the filler, all the formulations allowed the obtainment of final materials with haze values below 3%, the only exception being the formulation with the highest loading of GO (φ 0.03). The mechanisms underlying the experimental observations are discussed.