Architecture / Mimarlık

Permanent URI for this collectionhttps://hdl.handle.net/11147/24

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 10
    Citation - Scopus: 14
    Out-Of Seismic Performance of Bed-Joint Reinforced Autoclaved Aerated Concrete (aac) Infill Walls Damaged Under Cyclic In-Plane Displacement Reversals
    (Elsevier, 2023) Halıcı, Ömer Faruk; Demir, Uğur; Zabbar, Yassin; İlki, Alper
    The infill walls made of Autoclaved Aerated Concrete (AAC), which is a lightweight, fire resistant and energy efficient material, provide effective insulation solutions for building types of structures and becoming more and more popular in earthquake prone regions. Although the number of experimental tests examining the seismic response of clay brick infills is extensive, the amount of prior research on infill walls built of AAC blocks is rather limited. Past research revealed that the use of bed-joint reinforcement is one of the promising solutions to improve the global seismic response of masonry walls by enhancing strength and displacement capacity. In this study, the out-of-plane (OOP) seismic performance of AAC infill walls with flat-truss and innovative cord-type bed-joint reinforcement is experimentally evaluated. Also, consideration is given to the prior in-plane (IP) damage, which was found to degrade the seismic performance of infills in OOP direction. For this purpose, three IP and four OOP, in total, seven experimental tests were performed on four full-scale AAC infill wall specimens. The test parameters were selected in such a way as to make it possible to parametrically compare the OOP performance of AAC infills with flat-truss and cord-type bed-joint reinforcements with unreinforced AAC infill walls, together with the effect of prior IP damage on the OOP response of unreinforced AAC infill walls. It was found that the use of innovative cord-type bed-joint reinforcement improved the OOP strength to a similar extent to what was obtained from the truss-type reinforced specimen. In terms of ultimate displacement and energy dissipation capacity enhancement, the specimen with cord-type reinforcement performed better. In addition, the damages formed due to IP cyclic displacement reversals up to 0.005 drift ratio, which is defined as the drift limit for buildings with brittle infill walls in certain design codes, resulted in a significant reduction in the OOP strength and stiffness properties of AAC infills. The theoretical OOP strength calculations were found to provide unconservative strength values for the IP-damaged specimens.
  • Article
    Citation - WoS: 11
    Citation - Scopus: 10
    Assessment of Construction Techniques and Material Usage in Izmir Rural Houses
    (Taylor and Francis Ltd., 2015) Tunçoku, Selim Sarp; İnceköse, Ülkü; Akış, Tonguç; Yalçın, Mehmet Ali
    The domestic architecture in the rural villages of ̄zmir comprises a unique built environment with their masonry wall textures, semi-open sofas, round tiled-hipped roofs, and chimneys, and represents an important part of the cultural and architectural heritage. This assessment is mainly based on field observations that focus on the architectural and structural layout of intact, damaged, and destroyed houses. During field observation and the analysis of data certain plan typologies and relationships between the geological formations of the region and choice of materials and construction techniques were observed. While load-bearing masonry and timber skeleton systems are common, extensive use of timber laces, stone, and fired or adobe brick masonry with mud mortar and timber frames infilled with masonry materials were frequently seen. Generally, round timber elements such as wall plates, laces, lintels, posts, and frames of flooring systems are used. Architectural degenerations in authentic houses, defective details and partially due to the earthquake-prone nature of the region seismicity have been evaluated. An overall approach for the preservation and sustainability of this heritage is suggested.