Architecture / Mimarlık

Permanent URI for this collectionhttps://hdl.handle.net/11147/24

Browse

Search Results

Now showing 1 - 10 of 10
  • Article
    Citation - WoS: 7
    İşlev değişikliğinin tarihi yapılar üzerine etkileri “Alsancak Levanten Evleri örneği”
    (Yıldız Teknik Üniversitesi, 2015) Gazi Gezgin, Aylin; Boduroğlu, Elvin
    Social change brings with it new human needs and activities, and in every era humans create and recreate spaces, and hence structures, according to these needs and activities. This means that structures, and their parts, need to undergo change in terms of space and function to adapt to different functionalities and conditions. One understanding of preservation is based on the idea that with a change in function, historical structures which have outlived their original purpose are given new life and once again are made part of the urban landscape. Instances of functional change are most often seen in monumental and historical industrial structures, and in the examples of civil architecture remaining in areas set aside for housing settlements as a result of rapid urbanization. It is important, however, that any functional change made to a historical structure serves to protect the architectural value, meaning and memory of the structure. Alsancak is home to a large number of historical Levantine houses, many of which, following rapid urbanization in the 1970s, have had to change their function to that of bar or cafe. The main purpose of this study was to evaluate the effect of the re-functioning on these houses in Alsancak, and to make some recommendations on both the processes involved in re-functioning, and on the current legal regulations governing these processes with a view to ameliorating the negative effects of re-functioning on such structures.
  • Article
    Citation - WoS: 1
    Hafıza Kutusu: Bir Kentsel Kolektif Bellek Deneyi(mi)
    (Yıldız Teknik Üniversitesi, 2017) Doğu, Tuba; Varkal Deligöz, Melis
    Kentsel tasarımda kullanıcı katılımına verilen önem son yıllarda tüm dünyada artış göstermektedir. Türkiye’de de gerek yerel yönetimlerin teşviği, gerekse sivil insiyatifler ve mahalle örgütlenmeleriyle kentsel mekânların şekillenmesini gözlemlemek mümkündür. Buradan yola çıkan bu çalışma, 1960’lardan bu yana İzmir Güzelyalı’da yer alan bir kültür mekânının mahalleli eliyle dönüşümünü inceler. Sözlü tarih çalışmalarına yeni bir yöntem önerisi sunar ve mahallelinin ne denli etkin olduğunu okumak adına bir hatırlama süreci kurgular. Bu kurgu, kolektif bellek üzerinden kamusal bir yerleştirme olup, anlatılar ardındaki kolektif motivasyonu inceler. Amaç, geçmişi günümüzde okuyarak, kentsel mekânlarda yeni sivil eylemlere ışık tutmaktır.
  • Article
    Citation - WoS: 4
    Impact of Window-To Surface Area for Different Window Glass Types and Wall Orientations on Building Energy Performance: a Case Study for a School Building Located in Izmir, Turkey
    (Yıldız Teknik Üniversitesi, 2011) Yildiz, Yusuf; Ozbalta, Trkan Goksal; Arsan, Zeynep Durmus
    The opaque and transparent surfaces of buildings have an important role in the total percentage of energy loss or gain. Heat loss or gain from windows are dependent on the window-to-wall area ratio, the window glass type, and the type of window frame used. In the concept of energy efficient design, heat loss or gain from windows should be analyzed in detail in the early stages of building design by considering local climatic conditions. This study investigates a school building located in Izmir in Turkey, a city with a hot and humid climate. Various glass types with different glazing characteristics and number of layers, located in different parts of the buildings and with different window-to-wall ratios are analyzed and compared using building the energy analysis program "EnergyPlus". Results indicate that window-to-wall area ratios, wall orientation and glass types are important factors in the building's total energy consumption. When the window-to-wall area ratio is increased from 10% to 60%, the winter heating load of the building decreases in maximum amount on the south side of the building and reduces in minimum amount on the east side of the building. When summer cooling load is investigated the highest increase in energy consumption is found on the south side of the building. On the eastern and western sides of the building the effect of increased energy consumption value remains low. When the total energy consumption (cooling + heating) is considered, it is calculated that the east and west sides have the biggest total effect and the northern wall has the smallest total effect. When low emissivity glass is used instead of double layer glass, in terms of energy consumption the building side order of effect remains the same, although actual values differ. It is therefore clear that using energy analysis programs to analyse different factors within the energy consumption of buildings will be beneficial in creating energy efficient solutions. This can be carried out in the earlier stages of the architectural design of the buildings or at the renovation stages of existing buildings.
  • Article
    Citation - WoS: 7
    Investigation of Educational Buildings in Terms of Daylighting Performance
    (Yıldız Teknik Üniversitesi, 2011) Erlalelitepe, Ilknur; Aral, Duygu; Kazanasmaz, Tugce
    Educational buildings have the priority among other building types in daylight performance studies. There are several reasons for this. Classrooms which are used during the whole day should have sufficient and homogeneously distributed daylight. In insufficient daylight conditions, the use of electrical lighting increases energy consumption. Users' visual comfort should also be assured, and design incorporating natural light requires the analysis of sun protection devices in order to avoid glare and excessive heat. Also, atriums and skylights can be included in the building design with the aim of distributing light equally and in a relatively balanced manner throughout the building. However, lighting schemes are often proposed by architects and professionals who tend to make use of different design tools, and it would be pertinent to investigate whether these tools perform as desired. This study analyses daylight design principles and design elements in educational buildings. It outlines the method which has been used to analyse the daylight performance of buildings. A university building was selected for the field study. Measurements were taken in sample spaces to determine daylight performance. Utilising comparison between standard values and measured values, findings are presented in the form of tables, drawings and figures.
  • Article
    A Fuzzy Logic Model To Classify Design Efficiency of Nursing Unit Floors
    (Yıldız Teknik Üniversitesi, 2010) Kazanasmaz, Tugce; Tayfur, Gokmen
    This study was conducted to determine classifications for the planimetric design efficiency of certain public hospitals by developing a fuzzy logic algorithm. Utilizing primary areas and circulation areas from nursing unit floor plans, the study employed triangular membership functions for the fuzzy subsets. The input variables of primary areas per bed and circulation areas per bed were fuzzified in this model. The relationship between input variables and output variable of design efficiency were displayed as a result of fuzzy rules. To test existing nursing unit floors, efficiency output values were obtained and efficiency classes were constructed by this model in accordance with general norms, guidelines and previous studies. The classification of efficiency resulted from the comparison of hospitals.
  • Article
    Citation - WoS: 2
    The Development of Western-Type Large-Scale Consumption Areas in Turkey and Legal and Structural Regulation Efforts in Urban Retail Environments
    (Yıldız Teknik Üniversitesi, 2009) Kompil, Mert; Celik, Murat
    The retail sector has been experiencing a rapid and continuous change worldwide. There have also been profound changes in Turkey, especially after the 1980s. Both the retail sector and the urban retail environments have been altered radically. One of the most significant indicators of this change is the proliferation of western-type large-scale retail developments. Past experiences in developed countries have shown that the uncontrolled development of large-scale retail areas results in some undesired socioeconomic and physical outcomes, such as decline in the cultural and commercial activities of city centers, damage in existing retail workforce structure, and change in local retail hierarchy, nearby land uses, traffic loads and original architectural identity. Many countries have put into practice restrictive and regulatory policies to prevent these negative effects. As similar transformations have also been realized in Turkish retail environments, many institutions think that similar legal regulations must be implemented in Turkey as well. The present study investigates the ongoing retail change within the Turkish context, explores the legal and structural regulatory policies of the Organization for Economic Co-operation and Development (OECD) countries, and critically discusses the appropriate retail regulation policies for Turkey.
  • Article
    Efficient Design of Nursing Unit Floors
    (Yıldız Teknik Üniversitesi, 2009) Kazanasmaz, Z. Tugce; Duzgunes, Arda
    Hospital designs aim to obtain the lowest possible construction, maintenance and operational costs together with patient satisfaction, comfort and privacy. To satisfy these needs, the efficient design of nursing unit areas becomes considerably important. This study was thus conducted to analyze planimetric design efficiency of nursing unit floors by defining certain floor areas and floor area ratios. To test existing nursing unit floors, quantitative assessments were noted in regard to their planimetric efficiency: the utility value of the built floor area, both in terms of its allocation to patient space (served), support (serving) and circulation space and the relative proportions of these. Results were presented in a comparative table. Of the 15 hospital floor plans analyzed, five satisfied minimum space requirements for patient areas, while another five were in the optimum range for circulation areas. Two were defined as the least efficient, having the lowest patient-to-circulation area ratio.
  • Article
    Citation - WoS: 3
    Geometric and Kinematic Analysis of Deployable Doubly Ruled Hyperboloids
    (Yıldız Teknik Üniversitesi, 2017) Maden, Feray; Korkmaz, Koray
    This paper aims to develop deployable doubly ruled hyperboloid surfaces that can be used in architectural applications. First, the study systematically analyzes the geometric principles of hyperboloids generated by the ruled surface generation method and examines the morphology to generate different types of hyperboloids. Then, a method is introduced to construct deployable doubly ruled hyperboloid surfaces. The study demonstrates that deployment behavior of the hyperboloid is directly related to joint types used at the intersection points of the bars. Based on kinematic analysis, the study establishes that deployable hyperboloids with a single degree of freedom can be constructed only by revolute and spherical joints. Finally, various hyperboloids having different number of intersections are constructed according to the proposed joint types and their deployment capabilities are discussed.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 8
    Performance Indices of Soft Computing Models To Predict the Heat Load of Buildings in Terms of Architectural Indicators
    (Yıldız Teknik Üniversitesi, 2017) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Gökçen Akkurt, Gülden
    This study estimates the heat load of buildings in Izmir/Turkey by three soft computing (SC) methods; Artificial Neural Networks (ANNs), Fuzzy Logic (FL) and Adaptive Neuro-based Fuzzy Inference System (ANFIS) and compares their prediction indices. Obtaining knowledge about what the heat load of buildings would be in architectural design stage is necessary to forecast the building performance and take precautions against any possible failure. The best accuracy and prediction power of novel soft computing techniques would assist the practical way of this process. For this purpose, four inputs, namely, wall overall heat transfer coefficient, building area/ volume ratio, total external surface area and total window area/total external surface area ratio were employed in each model of this study. The predicted heat load is evaluated comparatively using simulation outputs. The ANN model estimated the heat load of the case apartments with a rate of 97.7% and the MAPE of 5.06%; while these ratios are 98.6% and 3.56% in Mamdani fuzzy inference systems (FL); 99.0% and 2.43% in ANFIS. When these values were compared, it was found that the ANFIS model has become the best learning technique among the others and can be applicable in building energy performance studies.
  • Article
    Citation - WoS: 7
    Citation - Scopus: 7
    The Importance of Internal Heat Gains for Building Cooling Design
    (Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    This paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.