Architecture / Mimarlık

Permanent URI for this collectionhttps://hdl.handle.net/11147/24

Browse

Search Results

Now showing 1 - 5 of 5
  • Article
    Citation - WoS: 20
    Citation - Scopus: 17
    Optimizing Thermal Comfort in Physical Exercise Spaces: a Study of Spatial and Thermal Factors
    (Elsevier, 2024) Avcı, Ali Berkay; Balcı, Görkem Aybars; Başaran, Tahsin
    Fitness centers have become famous for maintaining a healthy lifestyle. They require different thermal comfort conditions and higher fresh air supply rates than other indoor spaces. However, even well-designed centers may cause discomfort due to factors such as design decisions, ventilation, overheating, and overcrowding. The standards for fitness centers do not consider these specific requirements sufficiently, so this study focuses on understanding the thermal comfort requirements during physical exercise and evaluating spatial and thermal factors affecting the thermal environment around the body. The study investigated the ceiling height, lateral and frontal distances between machines, and vent locations as spatial factors and inlet temperature and air velocity as thermal factors. A thirty-minute moderate-intensity constant work rate exercise test was conducted in a controlled climatic chamber using a cycle ergometer with six healthy male participants. The experiment conditions were simulated in CFD software using the collected data. Once a validated simulation model was provided, computational models for different environmental and spatial scenarios for the five-person cycling class were generated. Using Taguchi L9 (34) orthogonal arrays method, nine spatial scenarios were simulated with three different thermal operations each. Optimal factor levels were determined by using thermal comfort conditions (based on predicted mean vote) around the body's thermal plume. The results showed that a ceiling height of 5 m, lateral and frontal distances of 1 m and 0.5 m between machines, and Type 2 (two inlets mounted on the ceiling) ventilation strategy were optimal for achieving better thermal comfort values in a thermal condition of 18 °C and 0.2 m·s−1. The study found that increasing the ceiling height and using cross-positioned vents that project air vertically from the ceiling improved the comfort conditions significantly. It is expected that these criteria, which were determined, compared with the standards and detailed, will contribute to the production processes of comfortable exercise spaces.
  • Conference Object
    Citation - Scopus: 1
    Comfort Based Investigation on Historic Libraries for User Satisfaction and Preservation of Paper-Based Collections
    (IOP Publishing, 2021) Turhan, Cihan; Topan, Çağrı; Durmuş Arsan, Zeynep; Göksal Özbalta, Türkan; Gökçen Akkurt, Gülden
    Historic libraries preserve cultural heritage values while housing rare manuscripts and paper-based collections. The collections in the libraries are deteriorated chemically, biologically and mechanically due to inappropriate indoor environment conditions such as temperature and relative humidity fluctuations and microbiological conditions. Apart from preserving vulnerable paper-based collections, accommodating of a considerable thermal comfort level for visitors is essential in historic libraries. The aim of this study is to analyse indoor environment of a historic library in terms of thermal comfort and preventive conservation of paper-based collections. Izmir National Library, built in 1933, is selected as a case study. Indoor air temperature, relative humidity and air velocity in the library were monitored with a one-year measurement campaign. Meanwhile, thermal comfort of the visitors was assessed with PMV/PPD indices and thermal sensation surveys. The results show that high chemical degradation risk is detected in the library while biological and mechanical degradations are in the low risk zone. On the other hand, 87% and 93% of the visitors feel thermally satisfied in heating and cooling seasons, respectively.
  • Article
    Citation - WoS: 20
    Citation - Scopus: 23
    Thermal Comfort Analysis of Historical Mosques. Case Study: the Ulu Mosque, Manisa, Turkey
    (Elsevier, 2021) Diler, Yusuf; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    Mosques are sanctuary places for Muslims where they can perform their religious activities and also can communicate with each other. On the other hand, historical mosques may contain artworks which have cultural heritage values. These mosques originally have not any Heating, Ventilating and Air Conditioning systems. For this reason, obtaining thermal comfort becomes a significant issue. In this study, a systematic approach on monitoring and evaluating thermal comfort of historical mosques were developed. As a case study, The Ulu Mosque, Manisa/Turkey was monitored from 2015 to 2018, and thermal comfort evaluation of the mosque was conducted during prayer times based on the method provided by ISO 7730. A dynamic Building Energy Performance Software, DesignBuilder, was used to model the mosque, and the model was calibrated by using hourly indoor temperature data. The calibrated model was then used to evaluate existing conditions of the mosque and develop retrofitting scenarios in order to increase thermal comfort of prayers. Thirteen different scenarios were proposed to improve thermal comfort of prayers during worship periods. The results were evaluated according to EN 16883 for conservation of cultural heritage of the mosque. Electrical radiator heating with intermittent operating schedules was obtained as the best scenario to protect cultural heritage via artworks, while decreasing disssatisfaction level of the prayers from 45% to 10% in winter months. Additionally, intermittent operation saved 46.9% of energy compared to continuous operating schedule. (C) 2021 Elsevier B.V. All rights reserved.
  • Article
    Citation - WoS: 15
    Citation - Scopus: 19
    Associations Between Thermal and Physiological Responses of Human Body During Exercise
    (MDPI, 2017) Başaran, Tahsin; Zora, Süleyman; Balcı, Görkem Aybars; Çolakoğlu, Muzaffer
    In this study, thermal behaviours of the athletes were investigated with respect to thermal comfort and exercise intensity. The relationship between an index for analysing thermal comfort (Predicted Mean Vote: PMV) and Rating of Perceived Exertion (RPE) which shows exercise intensity and exhaustion level was evaluated. Eleven moderately trained male athletes (V) over dotO(2max) 54 +/- 9.9 mL.min(-1).kg(-1)) had volunteered for the study (age: 22.2 +/- 3.7 years; body mass: 73.8 +/- 6.9 kg; height: 181 +/- 6.3 cm; Body surface area (BSA): 1.93 +/- 0.1 m(2); body fat: 12.6% +/- 4.2%; (V) over dotO(2max): 54 +/- 9.9 mL.min(-1).kg(-1)). Experiments were carried out by using a cycle ergometer in an air-conditioned test chamber which provided fresh air and had the ability to control the temperature and relative humidity. The study cohort was divided into two groups according to maximal oxygen consumption levels of the participants. Statistical analyses were conducted with the whole study cohort as well as the two separated groups. There was a moderate correlation between PMV and RPE for whole cohort (r: -0.51). When the whole cohort divided as low and high aerobic power groups, an average correlation coefficient at high oxygen consumption cohort decreased to r: -0.21, while the average correlation coefficient at low oxygen consumption cohort increased to r: -0.77. In conclusion, PMV and RPE have a high correlation in less trained participants, but not in the more trained ones. The case may bring to mind that thermal distribution may be better in high aerobic power group in spite of high RPE and thus the relation between PMV and RPE is affected by exercise performance status.
  • Article
    Citation - WoS: 6
    Citation - Scopus: 9
    Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone
    (Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden
    Most historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.