Architecture / Mimarlık
Permanent URI for this collectionhttps://hdl.handle.net/11147/24
Browse
12 results
Search Results
Now showing 1 - 10 of 12
Article Citation - WoS: 19Citation - Scopus: 21Integration of Energy-Efficient Ventilation Systems in Historic Buildings—review and Proposal of a Systematic Intervention Approach(MDPI, 2021) Rieser, Alexander; Pfluger, Rainer; Troi, Alexandra; Herrera-Avellanosa, Daniel; Thomsen, Kirsten Engelund; Rose, Jorgen; Durmuş Arsan, Zeynep; Gökçen Akkurt, Gülden; Kopeinig, Gerhard; Guyot, GaëlleHistoric building restoration and renovation requires sensitivity to the cultural heritage, historic value, and sustainability (i.e., building physics, energy efficiency, and comfort) goals of the project. Energy-efficient ventilation such as demand-controlled ventilation and heat recovery ventilation can contribute to the aforementioned goals, if ventilation concepts and airflow distribution are planned and realized in a minimally invasive way. Compared to new buildings, the building physics of historic buildings are more complicated in terms of hygrothermal performance. In particular, if internal insulation is applied, dehumidification is needed for robust and risk-free future use, while maintaining the building's cultural value. As each ventilation system has to be chosen and adapted individually to the specific building, the selection of the appropriate system type is not an easy task. For this reason, there is a need for a scientifically valid, systematic approach to pair appropriate ventilation system and airflow distribution solutions with historical buildings. This paper provides an overview of the interrelationships between heritage conservation and the need for ventilation in energy-efficient buildings, regarding building physics and indoor environmental quality. Furthermore, a systematic approach based on assessment criteria in terms of heritage significance of the building, building physics (hygrothermal performance), and building services (energy efficiency, indoor air quality, and comfort rating) according to the standard EN 16883:2017 are applied.Article Citation - WoS: 20Citation - Scopus: 23Thermal Comfort Analysis of Historical Mosques. Case Study: the Ulu Mosque, Manisa, Turkey(Elsevier, 2021) Diler, Yusuf; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMosques are sanctuary places for Muslims where they can perform their religious activities and also can communicate with each other. On the other hand, historical mosques may contain artworks which have cultural heritage values. These mosques originally have not any Heating, Ventilating and Air Conditioning systems. For this reason, obtaining thermal comfort becomes a significant issue. In this study, a systematic approach on monitoring and evaluating thermal comfort of historical mosques were developed. As a case study, The Ulu Mosque, Manisa/Turkey was monitored from 2015 to 2018, and thermal comfort evaluation of the mosque was conducted during prayer times based on the method provided by ISO 7730. A dynamic Building Energy Performance Software, DesignBuilder, was used to model the mosque, and the model was calibrated by using hourly indoor temperature data. The calibrated model was then used to evaluate existing conditions of the mosque and develop retrofitting scenarios in order to increase thermal comfort of prayers. Thirteen different scenarios were proposed to improve thermal comfort of prayers during worship periods. The results were evaluated according to EN 16883 for conservation of cultural heritage of the mosque. Electrical radiator heating with intermittent operating schedules was obtained as the best scenario to protect cultural heritage via artworks, while decreasing disssatisfaction level of the prayers from 45% to 10% in winter months. Additionally, intermittent operation saved 46.9% of energy compared to continuous operating schedule. (C) 2021 Elsevier B.V. All rights reserved.Article Citation - WoS: 21Citation - Scopus: 21Retrofit Strategies for Energy Efficiency of Historic Urban Fabric in Mediterranean Climate(MDPI, 2020) Ulu, Meltem; Durmuş Arsan, Zeynep; Arsan, Zeynep DurmuşEnergy-efficient retrofitting of historic housing stock requires methodical approach, in-depth analysis and case-specific regulatory system, yet only limited efforts have been realized. In large scale rehabilitation projects, it is essential to develop a retrofit strategy on how to decide energy-efficient solutions for buildings providing the most energy saving in a short time. This paper presents a pilot study conducted at a neighborhood scale, consisting of 22 pre-, early-republican and contemporary residential buildings in a historic urban fabric in the Mediterranean climate. This study aims to develop an integrated approach to describe case-specific solutions for larger scale historic urban fabric. It covers the building performance simulation (BPS) model and numerical analysis to determine the most related design parameters affecting annual energy consumption. All the case buildings were classified into three main groups to propose appropriate retrofit solutions in different impact categories. Retrofit solutions were gathered into two retrofit packages, Package 1 and 2, and separately, three individual operational solutions were determined, considering a five-levelled assessment criteria of EN 16883:2017 Standard. Energy classes of case buildings were calculated based on National Building Energy Regulations. Changes in building classes were evaluated considering pre- and post-retrofit status of the buildings. For the integrated approach, the most related design parameters on annual energy consumption were specified through Pearson correlation analysis. The approach indicated that three buildings, representing each building group, can initially be retrofitted. For all buildings, while maximum energy saving was provided by Package 2 with 48.57%, minimum energy saving was obtained from Package 1 with 19.8%.Article Citation - WoS: 1Citation - Scopus: 1Impact of Thermal Mass for Future Energy Consumption: Case Study in Adobe House(Inderscience Enterprises, 2019) Durmuş Arsan, Zeynep; Yöney, Ekin GamzeThis paper examines thermal mass quality of building envelope as passive preventive phenomena for future energy consumption. It questions how much and what type of thermal mass is required for decreasing energy consumption according to future climate change. Summer energy performance of adobe house in Konya, Turkey is studied in terms of thermal mass characteristic by using dynamic simulation software. Measured and predicted microclimate data for 2017 and 2050s are used to compare passive impact of wall material choices, i.e. adobe, limestone, vertical hollow brick and volume of wall without night-time ventilation. In conclusion, the study reveals that thermal mass with lower density and thinner materials show higher energy performance for summers. Energy consumption is minimum with vertical hollow brick wall in 50 cm for 2017 and 30 cm for 2050s. It is deduced that thermal conductivity will still have higher impact than thermal mass on energy consumption.Article Citation - WoS: 6Citation - Scopus: 9Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone(Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMost historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.Book Part Citation - Scopus: 2Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey(Elsevier, 2018) Coşkun, Turgay; Şahin, Cem Doğan; Gülhan, Özcan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenLibraries are specific spaces in which the indoor microclimate should meet rigorous requirements such as the thermal comfort of humans and the conservation of books, manuscripts, and cultural property. An inadequate indoor microclimate (mainly temperature, relative humidity, and their fluctuations) in libraries may cause chemical, biological, and mechanical degradations in paper-based collections. In this chapter, the indoor microclimate of the Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, is discussed from the perspective of the preventive conservation of manuscripts. The library, which has no active heating, cooling, and ventilation system, was modeled with the help of a building energy simulation tool, DesignBuilder. The indoor temperature and relative humidity were monitored throughout 1 year and the model was calibrated with respect to these measurements. To reduce the risks of the manuscripts degrading, ventilation strategies were proposed including natural and mechanical control. The results showed that risks of chemical degradation can be diminished to some extent. © 2018 Elsevier Inc. All rights reserved.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.Conference Object Citation - WoS: 21Citation - Scopus: 27Applying Underfloor Heating System for Improvement of Thermal Comfort in Historic Mosques: the Case Study of Salepçioglu Mosque, Izmir, Turkey(Elsevier Ltd., 2017) Bughrara, Khaled S. M.; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.Article Citation - WoS: 29Citation - Scopus: 39Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey(Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.