Architecture / Mimarlık
Permanent URI for this collectionhttps://hdl.handle.net/11147/24
Browse
13 results
Search Results
Now showing 1 - 10 of 13
Article Citation - WoS: 1Citation - Scopus: 1Design of Demountable Reciprocal Frames With New Geometric Properties(Int. Association for Shell and Spatial Structures, 2022) Özen, Gülçin; Kiper, Gökhan; Korkmaz, KorayThis study aims to develop missing geometric knowledge for demountable reciprocal frames (RF). While designing a demountable RF, one should know the initial, in-process and final form of the RF. These processes require some specific geometric knowledge. There are some deficiencies about geometric properties in the previous studies about demountable RFs. In this study, the positions and the orientations of the nexors are found by using the Denavit-Hartenberg parameters. This information gives where the joints are placed, how they are oriented and take position according to one another. Besides, the influence of engagement length on the fan height and the base edge are analyzed. Thereby one will be able to find out how much space the RF covers with the known base edge. With the geometric knowledge obtained from this study, demountable RFs having different engagement lengths can be produced with the same nexors.Article A Novel Design Method of Deployable Semi-Regular Tessellated Surfaces With Plano-Spherical Units(Int. Association for Shell and Spatial Structures, 2022) Maral, Mesude Oraj; Korkmaz, Koray; Kiper, GökhanThe design of movable systems gives an opportunity to create transformable designs which respond to the environmental, functional, cultural, and aesthetical needs of today's architecture. This paper proposes a method for designing a family of deployable structures which can be applied to semi-regular tessellated planar surfaces such as roofs, walls, and shading devices. The generated modular approach and adaptability provides a wide usage area and various combinations for these designs. The regular convex polygon modules are designed as a network of the triangular units. The triangular unit is designed using Bennett's overconstrained plano-spherical linkage topology. The polygonal modules are assembled to each other in one-uniform semi-regular tessellations. The assembly of adjacent regular convex polygons in each tessellation is examined to find a proper solution for no collision during deployment and to properly fit a surface without any gaps or overlaps in the deployed position. The assembly method for creating 1-DoF deployable surfaces and mobility calculations for a unit, the polygonal modules, and the assemblies are computed, and motion studies are demonstrated with CAD models and exemplified for a square module for motion tests in a prototype.Article Citation - WoS: 5Citation - Scopus: 5Loop Based Classification of Planar Scissor Linkages(Springer, 2022) Kiper, Gökhan; Korkmaz, Koray; Gür, Şebnem; Yar Uncu, Müjde; Maden, Feray; Akgün, Yenal; Karagöz, CevahirScissor linkages have been used for several applications since ancient Greeks and Romans. In addition to simple scissor linkages with straight rods, linkages with angulated elements have been introduced in the last decades. In the related literature, two methods have been used to design scissor linkages, one of which is based on scissor elements, and the other is based on assembling loops. This study presents a systematic classification of scissor linkages as assemblies of rhombus, kite, dart, parallelogram and anti-parallelogram loops using frieze patterns and long-short diagonal connections. After the loops are replicated along a curve as a pattern, the linkages are obtained by selection of proper common link sections for adjacent loops. The resulting linkages are analyzed for their motions and they are classified as realizing scaling deployable, angular deployable or transformable motion. Some of the linkages obtained are novel. Totally 10 scalable deployable, 1 angular deployable and 8 transformable scissor linkages are listed. Designers in architecture and engineering can use this list of linkages as a library of scissor linkage topologies.Article Citation - WoS: 19Citation - Scopus: 20A Critical Review on Classification and Terminology of Scissor Structures(Int. Association for Shell and Spatial Structures, 2019) Maden, Feray; Akgün, Yenal; Kiper, Gökhan; Gür, Şebnem; Yar, Müjde; Korkmaz, KorayWhen the existing literature on the research of scissor structures is thoroughly investigated, it is seen that different researchers use different terminologies and classifications especially for the definition of the primary units and the motion type. Some of the studies define the whole geometry based on the geometric properties of the primary scissor units and the unit lines while some other studies define it according to the loops. All these studies use different names for similar elements. This article aims to review the literature on the classification and terminology of scissor structures and represent the state of art on the studies. Tables are represented showing all approaches in the literature. In addition, the article criticizes the missing points of each terminology and definition, and proposes some new terminology. In order to arrive at this aim, different definitions of the primary scissor units and motion types used in key studies in the literature are investigated thoroughly. With several examples, it is demonstrated that naming the scissor units according to the resulting motion type might be misleading and it is better to specify the motion type for the whole structure. A classification for transformation of planar curves is presented.Article Citation - WoS: 6Citation - Scopus: 9Impact of Climate Change on Indoor Environment of Historic Libraries in Mediterranean Climate Zone(Inderscience Enterprises, 2019) Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMost historic library buildings house valuable paper-based collections that are kept in unconditioned environments. This vulnerable cultural heritage is expected to be highly affected by climate change in the future. In this study, indoor microclimate of an unconditioned historic library, Necip Pasa Library (Izmir, Turkey) is analysed for existing conditions and future climate data. The measured and predicted indoor microclimate data from 'present' till 2080s are used to determine possible chemical degredation risk on library collection and human comfort. Comparison of periodic results of future climate data indicates an increase in temperature that could cause both an increase in chemical degredation risk on the library collection and a decline in thermal comfort conditions. Mitigation of climate change effects on library collection and human comfort requires taking some actions such as adding light and adaptive mechanical solutions.Article Citation - WoS: 6Citation - Scopus: 5Design of Anti-Parallelogram Loop Assemblies(Int. Association for Shell and Spatial Structures, 2019) Gür, Şebnem; Korkmaz, Koray; Kiper, GökhanScissor mechanisms are frequently used for deployable structures and many studies have been conducted on the subject. Most of the studies consider scissor units as modules in the design process. An alternative approach is to utilize loops as the modules for design. In this paper, the design alternatives of single degree-of-freedom planar linkages comprising anti-parallelogram loops using the loop assembly method is presented. First, scissor mechanisms are reviewed. Next, the types of four-bar loops and the resulting linkages in the literature are introduced and those which are yet to be explored, anti-parallelogram being one of them, are identified. Then the loop assembly method and the examples in the literature are reviewed. As a method to form as many alternatives as possible, symmetry operations are proposed. Suitable frieze symmetry groups utilized for obtaining the assemblies are explained and the anti-parallelogram loop patterns are derived. Next, the single degree-of-freedom linkages are obtained from the loop assemblies. Finally, a selection of the resulting linkages with novel properties are presented. This study shows that loop assemblies are efficient in systematic type synthesis of scissor linkages, some types of which could not be foreseen by using units as modules.Article Citation - WoS: 7Citation - Scopus: 8Performance Indices of Soft Computing Models To Predict the Heat Load of Buildings in Terms of Architectural Indicators(Yıldız Teknik Üniversitesi, 2017) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Gökçen Akkurt, GüldenThis study estimates the heat load of buildings in Izmir/Turkey by three soft computing (SC) methods; Artificial Neural Networks (ANNs), Fuzzy Logic (FL) and Adaptive Neuro-based Fuzzy Inference System (ANFIS) and compares their prediction indices. Obtaining knowledge about what the heat load of buildings would be in architectural design stage is necessary to forecast the building performance and take precautions against any possible failure. The best accuracy and prediction power of novel soft computing techniques would assist the practical way of this process. For this purpose, four inputs, namely, wall overall heat transfer coefficient, building area/ volume ratio, total external surface area and total window area/total external surface area ratio were employed in each model of this study. The predicted heat load is evaluated comparatively using simulation outputs. The ANN model estimated the heat load of the case apartments with a rate of 97.7% and the MAPE of 5.06%; while these ratios are 98.6% and 3.56% in Mamdani fuzzy inference systems (FL); 99.0% and 2.43% in ANFIS. When these values were compared, it was found that the ANFIS model has become the best learning technique among the others and can be applicable in building energy performance studies.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.Article Citation - WoS: 29Citation - Scopus: 39Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey(Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.
