Architecture / Mimarlık
Permanent URI for this collectionhttps://hdl.handle.net/11147/24
Browse
11 results
Search Results
Now showing 1 - 10 of 11
Conference Object Citation - Scopus: 1Comfort Based Investigation on Historic Libraries for User Satisfaction and Preservation of Paper-Based Collections(IOP Publishing, 2021) Turhan, Cihan; Topan, Çağrı; Durmuş Arsan, Zeynep; Göksal Özbalta, Türkan; Gökçen Akkurt, GüldenHistoric libraries preserve cultural heritage values while housing rare manuscripts and paper-based collections. The collections in the libraries are deteriorated chemically, biologically and mechanically due to inappropriate indoor environment conditions such as temperature and relative humidity fluctuations and microbiological conditions. Apart from preserving vulnerable paper-based collections, accommodating of a considerable thermal comfort level for visitors is essential in historic libraries. The aim of this study is to analyse indoor environment of a historic library in terms of thermal comfort and preventive conservation of paper-based collections. Izmir National Library, built in 1933, is selected as a case study. Indoor air temperature, relative humidity and air velocity in the library were monitored with a one-year measurement campaign. Meanwhile, thermal comfort of the visitors was assessed with PMV/PPD indices and thermal sensation surveys. The results show that high chemical degradation risk is detected in the library while biological and mechanical degradations are in the low risk zone. On the other hand, 87% and 93% of the visitors feel thermally satisfied in heating and cooling seasons, respectively.Article Citation - WoS: 20Citation - Scopus: 23Thermal Comfort Analysis of Historical Mosques. Case Study: the Ulu Mosque, Manisa, Turkey(Elsevier, 2021) Diler, Yusuf; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMosques are sanctuary places for Muslims where they can perform their religious activities and also can communicate with each other. On the other hand, historical mosques may contain artworks which have cultural heritage values. These mosques originally have not any Heating, Ventilating and Air Conditioning systems. For this reason, obtaining thermal comfort becomes a significant issue. In this study, a systematic approach on monitoring and evaluating thermal comfort of historical mosques were developed. As a case study, The Ulu Mosque, Manisa/Turkey was monitored from 2015 to 2018, and thermal comfort evaluation of the mosque was conducted during prayer times based on the method provided by ISO 7730. A dynamic Building Energy Performance Software, DesignBuilder, was used to model the mosque, and the model was calibrated by using hourly indoor temperature data. The calibrated model was then used to evaluate existing conditions of the mosque and develop retrofitting scenarios in order to increase thermal comfort of prayers. Thirteen different scenarios were proposed to improve thermal comfort of prayers during worship periods. The results were evaluated according to EN 16883 for conservation of cultural heritage of the mosque. Electrical radiator heating with intermittent operating schedules was obtained as the best scenario to protect cultural heritage via artworks, while decreasing disssatisfaction level of the prayers from 45% to 10% in winter months. Additionally, intermittent operation saved 46.9% of energy compared to continuous operating schedule. (C) 2021 Elsevier B.V. All rights reserved.Book Part Citation - Scopus: 2Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey(Elsevier, 2018) Coşkun, Turgay; Şahin, Cem Doğan; Gülhan, Özcan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenLibraries are specific spaces in which the indoor microclimate should meet rigorous requirements such as the thermal comfort of humans and the conservation of books, manuscripts, and cultural property. An inadequate indoor microclimate (mainly temperature, relative humidity, and their fluctuations) in libraries may cause chemical, biological, and mechanical degradations in paper-based collections. In this chapter, the indoor microclimate of the Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, is discussed from the perspective of the preventive conservation of manuscripts. The library, which has no active heating, cooling, and ventilation system, was modeled with the help of a building energy simulation tool, DesignBuilder. The indoor temperature and relative humidity were monitored throughout 1 year and the model was calibrated with respect to these measurements. To reduce the risks of the manuscripts degrading, ventilation strategies were proposed including natural and mechanical control. The results showed that risks of chemical degradation can be diminished to some extent. © 2018 Elsevier Inc. All rights reserved.Article Citation - WoS: 7Citation - Scopus: 8Performance Indices of Soft Computing Models To Predict the Heat Load of Buildings in Terms of Architectural Indicators(Yıldız Teknik Üniversitesi, 2017) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Gökçen Akkurt, GüldenThis study estimates the heat load of buildings in Izmir/Turkey by three soft computing (SC) methods; Artificial Neural Networks (ANNs), Fuzzy Logic (FL) and Adaptive Neuro-based Fuzzy Inference System (ANFIS) and compares their prediction indices. Obtaining knowledge about what the heat load of buildings would be in architectural design stage is necessary to forecast the building performance and take precautions against any possible failure. The best accuracy and prediction power of novel soft computing techniques would assist the practical way of this process. For this purpose, four inputs, namely, wall overall heat transfer coefficient, building area/ volume ratio, total external surface area and total window area/total external surface area ratio were employed in each model of this study. The predicted heat load is evaluated comparatively using simulation outputs. The ANN model estimated the heat load of the case apartments with a rate of 97.7% and the MAPE of 5.06%; while these ratios are 98.6% and 3.56% in Mamdani fuzzy inference systems (FL); 99.0% and 2.43% in ANFIS. When these values were compared, it was found that the ANFIS model has become the best learning technique among the others and can be applicable in building energy performance studies.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.Conference Object Citation - WoS: 21Citation - Scopus: 27Applying Underfloor Heating System for Improvement of Thermal Comfort in Historic Mosques: the Case Study of Salepçioglu Mosque, Izmir, Turkey(Elsevier Ltd., 2017) Bughrara, Khaled S. M.; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenMosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.Article Citation - WoS: 29Citation - Scopus: 39Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey(Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.Article Citation - WoS: 74Citation - Scopus: 85A Transdisciplinary Approach on the Energy Efficient Retrofitting of a Historic Building in the Aegean Region of Turkey(Elsevier Ltd., 2015) Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Tunçoku, Selim Sarp; Broström, Tor; Gökçen Akkurt, GüldenAbstract Buildings account for 40% of total energy consumption in the European Union, yet at the same time they have considerable energy saving potentials. Historic buildings should be treated different from contemporary ones when it comes to energy improvements. The specifications which underline historical, sociocultural and architectural values require certain care during realization of energy saving implementations to sustain these values. The purpose of this study is to demonstrate how the energy efficient retrofitting in historic buildings should be managed in a transdisciplinary approach with a case study conducted on the historic building in ̄zmir - Turkey. A detailed building energy simulation tool was used to determine the impacts of energy efficient retrofits. The actual energy consumption of case building was based on the utility bills regarding electricity and heating fuel consumption. Building energy simulation tool was calibrated by comparing the measured and simulated indoor air temperatures and total energy consumptions. The inappropriate retrofits, which contradict to the cultural heritage values, were eliminated with a transdisciplinary approach. Later appropriate retrofits were gathered into three packages to evaluate their effects on the energy consumption. The results show that energy saving of more than 34% can be obtained without damaging the heritage values.Article Citation - WoS: 96Citation - Scopus: 105Comparative Study of a Building Energy Performance Software (kep-Iyte and Ann-Based Building Heat Load Estimation(Elsevier Ltd., 2014) Turhan, Cihan; Kazanasmaz, Zehra Tuğçe; Erlalelitepe Uygun, İlknur; Ekmen, Kenan Evren; Gökçen Akkurt, GüldenThe several parameters affect the heat load of a building; geometry, construction, layout, climate and the users. These parameters are complex and interrelated. Comprehensive models are needed to understand relationships among the parameters that can handle non-linearities. The aim of this study is to predict heat load of existing buildings benefiting from width/length ratio, wall overall heat transfer coefficient, area/volume ratio, total external surface area, total window area/total external surface area ratio by using artificial neural networks and compare the results with a building energy simulation tool called KEP-IYTE-ESS developed by Izmir Institute of Technology. A back propagation neural network algorithm has been preferred and both simulation tools were applied to 148 residential buildings selected from 3 municipalities of Izmir-Turkey. Under the given conditions, a good coherence was observed between artificial neural network and building energy simulation tool results with a mean absolute percentage error of 5.06% and successful prediction rate of 0.977. The advantages of ANN model over the energy simulation software are observed as the simplicity, the speed of calculation and learning from the limited data sets.
