Coşkun, Turgay
Loading...
Profile URL
Name Variants
Coşkun, T
Coskun, Turgay
Coskun, T
Coskun, T.
Coşkun, T.
Coskun, Turgay
Coskun, T
Coskun, T.
Coşkun, T.
Job Title
Email Address
turgaycoskun@iyte.edu.tr
Main Affiliation
03.10. Department of Mechanical Engineering
Status
Current Staff
Website
ORCID ID
Scopus Author ID
Turkish CoHE Profile ID
Google Scholar ID
WoS Researcher ID
Sustainable Development Goals
1NO POVERTY
0
Research Products
2ZERO HUNGER
0
Research Products
3GOOD HEALTH AND WELL-BEING
0
Research Products
4QUALITY EDUCATION
0
Research Products
5GENDER EQUALITY
0
Research Products
6CLEAN WATER AND SANITATION
0
Research Products
7AFFORDABLE AND CLEAN ENERGY
1
Research Products
8DECENT WORK AND ECONOMIC GROWTH
0
Research Products
9INDUSTRY, INNOVATION AND INFRASTRUCTURE
2
Research Products
10REDUCED INEQUALITIES
0
Research Products
11SUSTAINABLE CITIES AND COMMUNITIES
1
Research Products
12RESPONSIBLE CONSUMPTION AND PRODUCTION
0
Research Products
13CLIMATE ACTION
0
Research Products
14LIFE BELOW WATER
0
Research Products
15LIFE ON LAND
0
Research Products
16PEACE, JUSTICE AND STRONG INSTITUTIONS
0
Research Products
17PARTNERSHIPS FOR THE GOALS
0
Research Products

Documents
9
Citations
140
h-index
6

This researcher does not have a WoS ID.

Scholarly Output
12
Articles
8
Views / Downloads
18601/4868
Supervised MSc Theses
1
Supervised PhD Theses
1
WoS Citation Count
116
Scopus Citation Count
140
Patents
0
Projects
0
WoS Citations per Publication
9.67
Scopus Citations per Publication
11.67
Open Access Source
9
Supervised Theses
2
| Journal | Count |
|---|---|
| Research on Engineering Structures and Materials | 2 |
| Exergetic, Energetic and Environmental Dimensions | 1 |
| Heat Transfer | 1 |
| Heat Transfer Engineering | 1 |
| International Journal of Heat and Mass Transfer | 1 |
Current Page: 1 / 2
Scopus Quartile Distribution
Competency Cloud

12 results
Scholarly Output Search Results
Now showing 1 - 10 of 12
Article Citation - WoS: 7Citation - Scopus: 7The Importance of Internal Heat Gains for Building Cooling Design(Yıldız Teknik Üniversitesi, 2017) Coşkun, Turgay; Turhan, Cihan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThis paper aims to investigate the effect of internal heat gains on the cooling load of a building. The house occupied by three adult men is selected as the case study for paper. The house is in the third floor of the apartment. The apartment has four flats and it has no insulation around the external walls. The heat dissipation from lighting devices, electrical equipment and the occupants are calculated by using the DesignBuilder v4 Beta release simulation program. The temperature of the house is observed during three weeks by using hobo data loggers and calibration of the measurements is made with respect to weather data file of the flat. Detailed schedule based on time of operation and occupancy is prepared to get more accurate results. Annual energy consumption and cooling load of the house is determined by using the dynamic simulation program.Article Citation - WoS: 18Citation - Scopus: 22A Review of Heat and Fluid Flow Characteristics in Microchannel Heat Sinks(John Wiley and Sons Inc., 2020) Coşkun, Turgay; Çetkin, ErdalHeat transfer and flow characteristic in microchannel heat sinks (MCHS) are extensively studied in the literature due to high heat transfer rate capability by increased heat transfer surface area relative to the macroscale heat sinks. However, heat transfer and fluid flow characteristics in MCHS differ from conventional ones because of the scaling effects. This review summarizes the studies that are mainly based on heat transfer and fluid flow characteristic in MCHS. There is no consistency among the published results; however, everyone agrees on that there is no new physical phenomenon in microscale that does not exist at macroscale. Only difference between them is that the effect of some physical phenomena such as viscous dissipation, axial heat conduction, entrance effect, rarefaction, and so forth, is negligibly small at macroscale, whereas it is not at microscale. The effect of these physical phenomena on the heat transfer and flow characteristics becomes significant with respect to specified conditions such as Reynolds number, Peclet number, hydraulic diameter, and heat transfer boundary conditions. Here, the literature was reviewed to document when these physical phenomena become significant and insignificant.Article Citation - WoS: 29Citation - Scopus: 39Investigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkey(Elsevier Ltd., 2017) Şahin, Cem Doğan; Çoşkun, Turgay; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.Article Citation - WoS: 35Citation - Scopus: 38Heat Transfer Enhancement in a Microchannel Heat Sink: Nanofluids And/Or Micro Pin Fins(Taylor & Francis, 2020) Coşkun, Turgay; Çetkin, ErdalHere, we show that overall thermal conductance in a rectangular microchannel heat sink can be maximized with the combination of nanofluids and micro pin fins. We uncover the effect of micro pin fins and nanofluids both separately and simultaneously in order to uncover their effect on the thermal conductance (i.e., thermal resistance). Both nanofluids and micro pin fins decrease the overall thermal resistance due to increase in the average thermal conductivity of the flow system. In addition, they increase the heat transfer surface area of the solid interacting with the fluid. However, the pumping power (pressure drop) increases in both methods due to the increase in the resistances to the fluid flow. The results document what should be the nanoparticle volume fraction mixed into the base fluid and the micro pin fin volume in order to minimize thermal resistance. If the thermal conductivity of the nanoparticles and micro pin fins are the same, the thermal conductance becomes the maximum with 4% and 0.14% volume fractions for the nanofluid and micro pin fins, respectively. This result shows that inserting micro pin fins and using nanofluids with a given volume fraction ratio maximize the overall thermal conductance. © 2019, © 2019 Taylor & Francis Group, LLC.Article Citation - WoS: 18Citation - Scopus: 20Cold Plate Enabling Air and Liquid Cooling Simultaneously: Experimental Study for Battery Pack Thermal Management and Electronic Cooling(Elsevier, 2023) Coşkun, Turgay; Çetkin, ErdalThe temperature of cells varies greatly during dis/charge while their performance and lifetime are greatly affected by this fluctuation. Elevated temperatures may yield battery fire due to thermal runaway as well they accelerate ageing and capacity fade of cells. Thermal management systems are a necessity for electric vehicles to extend the lifetime of battery cells and eliminate any fire risks, especially for fast dis/charging applications. Here, we document a hybrid cold plate with a working fluid(s) of sole air or liquid as well as both of them. Hybridization of air and liquid cooling promises to minimize energy consumption requirements during a charge/ discharge cycle by combining the benefits of both thermal management strategies if energy management is controlled accordingly. The temperature of each cell can be kept below 30 degrees C with the proposed hybrid cooling heat exchanger, and the temperature difference between the cells is reduced by 30 % relative to liquid cooling. The maximum temperatures are decreased by 18 % and 3 % in hybrid cooling when compared to air and water cooling, respectively. Furthermore, a step function combining various discharge rates (1C and 3C) was employed in experiments to mimic a realistic situation, i.e. variable C-rate rather than constant. The results show that the temperature of the battery cells can be kept below 30 degrees C with air cooling for variable discharge rate and the effect of contact resistance should not be overlooked for liquid cooling. Furthermore, the possible use of the proposed hybrid cold plates is surveyed in the cooling of electronic devices which produce more and continuous heat than cells. Therefore, three resistance heaters with a capacity of 50W are used in experiments as well. The results show that the proposed cold plates could be used in both electronics cooling and battery thermal management with a control algorithm to switch between sole working fluid and combination modes which could be developed based on the results of this paper.Book Part Citation - Scopus: 2Ventilation Strategies for the Preventive Conservation of Manuscripts in the Necip Paşa Library, Izmir, Turkey(Elsevier, 2018) Coşkun, Turgay; Şahin, Cem Doğan; Gülhan, Özcan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenLibraries are specific spaces in which the indoor microclimate should meet rigorous requirements such as the thermal comfort of humans and the conservation of books, manuscripts, and cultural property. An inadequate indoor microclimate (mainly temperature, relative humidity, and their fluctuations) in libraries may cause chemical, biological, and mechanical degradations in paper-based collections. In this chapter, the indoor microclimate of the Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, is discussed from the perspective of the preventive conservation of manuscripts. The library, which has no active heating, cooling, and ventilation system, was modeled with the help of a building energy simulation tool, DesignBuilder. The indoor temperature and relative humidity were monitored throughout 1 year and the model was calibrated with respect to these measurements. To reduce the risks of the manuscripts degrading, ventilation strategies were proposed including natural and mechanical control. The results showed that risks of chemical degradation can be diminished to some extent. © 2018 Elsevier Inc. All rights reserved.Article Vascularized Mini Cooling Channels To Achieve Temperature Uniformity: Battery Thermal Management and Electronic Cooling(MIM RESEARCH GROUP, 2023) Coşkun, Turgay; Çetkin, ErdalHere we propose to use of distinct vascularized plates to be used in the applications of battery thermal management and electronic cooling. The temperatures of battery cells increase during charge and discharge; and elevated temperature values in them accelerated degradation and even may trigger battery fire because of the thermal runaway. Therefore, thermal management system is a necessity for battery packs to increase the battery performance and diminish the risk factors in the electric vehicles. Generally, high amount of heat is released in the high capacity (>15 Ah) cells in short time interval under fast charge/discharge conditions; thus, thermal management of the battery system can be achieved with liquid cooling in that situation. A silicon heater system which represents the thermal behavior of a battery cell is manufactured based on the literature and it is used in experiments. Such a method has not proposed up to now in the literature, so the study may be creating a new experimental procedure for future studies without the risk of battery fire/degradation to uncover even extreme conditions experimentally. Electronic cooling is also in prime importance due to enhanced computing requirement of current systems, and vascularized plates can solve the hot spot problems occurring with decreased energy consumption. According to the results, the cooling capacity of the vascularized plates are calculated as 20W, and a battery cell can be kept within its optimal operating temperature range when the heat loads up to 30W. Also, the temperature uniformity along the surface of mimic of the battery is satisfied by vascularized plates.Article Citation - WoS: 3Citation - Scopus: 4The Effect of Structural Retrofitting and Ventilation Scenarios on the Indoor Microclimate of a Historical Library: The Necip Pasa Library, Turkiye(Elsevier Ltd, 2024) Coskun,T.; Arsan,Z.D.; Akkurt,G.G.Structural retrofitting in buildings may result in changes in the indoor microclimate. Chemical, mechanical and biological deterioration can be seen in the cultural properties as a consequence of substrates and inappropriate microclimatic conditions such as high indoor temperature, relative humidity and fluctuations of them. The primary aim of the study is to evaluate the effect of the structural retrofitting, that the building underwent, on the chemical degradation risk of the library collection based on two different ventilation scenarios. One is natural ventilation which is an existing situation since the building is free-floating. The other one implementing a mechanical ventilation system into the building. To be able to compare the microclimate that affects the library collection pre- and post-retrofitting, two models are developed in DesginBuilder and simulated for both scenarios. According to the results of the post-retrofitting model, mechanical ventilation reduced the risk of chemical degradation by 38 %, while natural ventilation did not cause any effect. Natural ventilation gives a similar output in the pre-retrofitting model as in the post-retrofitting model. Mechanical ventilation in the pre-retrofitting model achieves a 33 % reduction in chemical degradation risk. Structural retrofitting only achieves a 1 % reduction in the chemical risk level for both ventilation scenarios. Thus, its effect on the indoor microclimate is insignificant. This study shows that creating simulation models effectively assesses potential risks pre-post-structural retrofitting or any retrofitting in historical buildings. Simulations reveal that mechanical ventilation is a better choice for decreasing chemical degradation risks for the library. © 2024 Elsevier LtdArticle The Effect of Time Delay of Fluid Flow in a Vascularized Plate(MIM Research Group, 2018) Yenigün, Onur; Coşkun, Turgay; Çetkin, ErdalIn this study, we show the effect of time delay of coolant fluid flow into a vascularized plate on the peak temperature. Coolant flows along vascular channels which were embedded in a rectangular plate. Two kinds of vascular channel designs were investigated experimentally: parallel and tree-shaped. In the study, the peak temperatures were monitored and the coolant was pumped when the peak temperature reaches to 50°C, 70°C and 90°C. The performance comparison of two distinct designs is based on two criteria: the time required for the steady state condition after the coolant is pumped and the peak temperature after the steady state condition is conformed. The results show that the time required to reach steady-state condition increases as the time delay increases. The parallel and tree-shaped designs show similar performance (time required to reach steady state) with slightly improved performance in the tree-shaped design as the preset temperature for time delay increases. For instance, 4% decrease in the time required to reach steady-state with the tree-shaped design relative to the parallel design was achieved when the preset temperature for time delay is 90°C.Conference Object Citation - WoS: 6Citation - Scopus: 8The Effect of Spatial Interventions on Historic Buildings' Indoor Climate (case Study: Tire Necip Paşa Library, Izmir-Turkey)(Elsevier Ltd., 2017) Coşkun, Turgay; Gülhan, Özcan; Şahin, Cem Doğan; Durmuş Arsan, Zeynep; Gökçen Akkurt, GüldenThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.
