Arsenite and Arsenate Removals From Groundwater by Electrocoagulation Using Iron Ball Anodes: Influence of Operating Parameters
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Open Access Color
BRONZE
Green Open Access
Yes
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Removals of arsenite (As(III)) and arsenate (As(V)) from groundwater by a cylindrical packed-bed electrocoagulation (EC) reactor using Fe ball anodes were investigated in this study. Effects of some operating parameters such as initial pH (pHi of 6.5–8.5), applied current (i of 0.075–0.30 A), initial concentration (Co of 30–200 μg/L), diameter of iron ball (dp of 5.0–10.0 mm), height of anode balls in the reactor (h of 2–8 cm) and airflow rate (Qair of 0.0–6.0 L/min) on the removal efficiency of arsenic were evaluated. The removal efficiency of arsenic decreased with increase in concentrations of arsenic from 30 to 200 μg/L while its removal efficiency increased with increase in operating time, applied current, height of anode in the reactor, and airflow rate. The optimum operating conditions for effective As(III) and As(V) removals to meet the permissible level of arsenic effluent concentration of <10 μg/L were determined as 0.3 A, 14 min of EC time for As(III) and 12 min for As(V), a pHi of 7.5, Co of 200 μg/L, dp of 7.5 mm, h of 7.5 cm and Qair of 6 L/min, respectively. Arsenic removal efficiency, energy and electrode consumptions, operating cost, charge loading and arsenic removed capacity per amount of electrochemically generated Fe at the optimum conditions were also calculated as 96.0%, 1.442 kWh/m3, 0.0752 kg/m3, 0.612 $/m3, 252 C and 2.55 μg/mg Fe (0.762 μg/C) for As(III) removal and 95.8%, 1.386 kWh/m3, 0.0628 kg/m3, 0.546 $/m3, 216 C and 3.05 μg/mg Fe (0.887 μg/C) for As(V) removal, respectively.
Description
Keywords
Arsenite and arsenate removals, Electrocoagulation, Groundwater, Iron ball electrode, Operating cost, Arsenite and arsenate removals, Operating cost, Electrocoagulation, Iron ball electrode, Groundwater
Fields of Science
0211 other engineering and technologies, 02 engineering and technology, 01 natural sciences, 0105 earth and related environmental sciences
Citation
Şık, E., Demirbaş, E., Gören, A. Y., Öncel, M. S., and Kobya, M. (2017). Arsenite and arsenate removals from groundwater by electrocoagulation using iron ball anodes: Influence of operating parameters. Journal of Water Process Engineering, 18, 83-91. doi:10.1016/j.jwpe.2017.06.004
WoS Q
Scopus Q

OpenCitations Citation Count
27
Volume
18
Issue
Start Page
83
End Page
91
PlumX Metrics
Citations
Scopus : 29
Captures
Mendeley Readers : 67
Google Scholar™


