Sleep Quality: Design of Bedroom Ventilation and Evaluation Within the Scope of Current Standards

Loading...

Date

2025

Authors

Karadeniz, Ziya Haktan
Toksoy, Macit

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Science Sa

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Indoor air pollution is one of the leading environmental risks to public health considering people now spending nearly 90 % of their day in indoor environments. A significant portion of this time indoors is devoted to sleeping, making it crucial to address the impact of indoor environmental conditions on sleep quality. International ventilation standards such as ASHRAE and CEN, as well as country-specific guidelines, offer valuable recommendations for ventilation design in residential buildings, including bedrooms. This study aims to evaluate the importance of determining ventilation rates in sleeping spaces using Indoor Air Quality Procedure (IAQP) compared to Ventilation Rate Procedure (VRP) in accordance with current standards. Here, the IAQP approach for determining air flow rate is based on the CO2 balance by maintaining CO2 levels in any sleeping environment below specified upper limits of 750 ppm and 1000 ppm. This study focused on the adult population, which forms the majority of society, with analyses conducted for both single and double occupancy sleeping conditions. The volume of environment where ventilation is not required during sleep (Vf) is inaccessible in conventional sleeping environments (10-21.6 m3 per person). Therefore, proper ventilation is of great importance for any sleeping space that is smaller than the Vf. The results of the analyses show that for the conventional sleeping volumes, CO2 levels reach 750 ppm (upper limit for comfortable sleep) in the first hour and increase to the disturbed sleep zone in about 2 h. Additionally, a chart outlining the necessary ventilation flow rates is suggested for maintaining maximum CO2 concentrations of 750 and 1000 ppm during different sleep durations and in various sleeping environments with varying volumes. Finally, the ventilation rates determined based on unit area and/or occupancy levels in standards (referred to as VRP) may not always be adequate or may be excessive in order to maintain CO2 concentrations below the recommended limits of 750 and 1000 ppm. It is advised to utilize demand-controlled ventilation by considering the system design as recommended by IAQP.

Description

Sofuoglu, Sait C./0000-0001-6990-0275; Karadeniz, Z. Haktan/0000-0001-7850-7942

Keywords

Sleep Quality, Indoor Air Quality, Ventilation Rate Procedure, Indoor Air Quality Procedure, Ventilation

Fields of Science

Citation

WoS Q

Q1

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Energy and Buildings

Volume

327

Issue

Start Page

End Page

PlumX Metrics
Citations

Scopus : 2

Captures

Mendeley Readers : 14

SCOPUS™ Citations

2

checked on Apr 27, 2026

Web of Science™ Citations

2

checked on Apr 27, 2026

Page Views

92

checked on Apr 27, 2026

Downloads

3

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
2.19287517

Sustainable Development Goals

GOOD HEALTH AND WELL-BEING3
GOOD HEALTH AND WELL-BEING