Seismic Performance of Substandard Rc Columns Retrofitted With Sprayed Gfrm

Loading...

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

There is a myriad amount of substandard reinforced concrete (RC) buildings in developing countries that do not comply with the requirements and instructions of the current building design codes. In particular, columns in these substandard buildings demonstrate unsatisfactory and undesired behavior against lateral loads, mainly due to low concrete compressive strength and poor reinforcement detailing. The problem is exacerbated when the axial load ratio (ratio of applied axial load to the axial load capacity) and/or the shear ratio (ratio of shear force corresponding to moment capacity (Ve) to the shear capacity (Vr)) is/are high, leading to brittle failure modes. In this study, three full-scale substandard RC columns subjected to high axial load ratio of 0.75 were tested under constant axial load combined with reversed cyclic lateral displacements. Shear ratio (Ve/Vr) of the substandard columns were 0.75 and 0.82 according to ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and (Turkish Building Earthquake Code (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), respectively. According to the TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey), columns had a high Ve/(fctmbd) ratio of 1.12, where, fctm, b, and d are the direct tensile strength of concrete, width of the cross-section, and effective depth of the section. The ratio of transverse reinforcement to minimum required transverse reinforcement according to the ACI 318-19 (ACI 318 (2019) Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI, USA) and TBEC (Turkish Building Earthquake Code (TBEC) (2018) Disaster & Emergency Management Authority, Ankara, Turkey) was 0.19 and 0.77, respectively. Two of the columns were retrofitted with an innovative, cost-effective, and easily-applicable strengthening method, through external jacketing with sprayed glass fiber reinforced mortar (GFRM) of different characteristics. The remaining column was tested as the reference specimen to evaluate the efficiency of the strengthening method. The test results demonstrated the extremely poor performance of the reference substandard column as well as the remarkable lateral load capacity and ductility improvement provided by the adopted novel strengthening approach.

Description

Keywords

Basalt mesh, GFRM, Reinforced concrete column, Strengthening

Fields of Science

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
5

Volume

198 LNCE

Issue

Start Page

1317

End Page

1328
PlumX Metrics
Captures

Mendeley Readers : 10

SCOPUS™ Citations

2

checked on May 03, 2026

Web of Science™ Citations

1

checked on May 03, 2026

Page Views

1801

checked on May 03, 2026

Downloads

2

checked on May 03, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
3.12113721

Sustainable Development Goals

NO POVERTY1
NO POVERTY
SUSTAINABLE CITIES AND COMMUNITIES11
SUSTAINABLE CITIES AND COMMUNITIES