On-Site Measurements of Temperature and Humidity Conditions for the Comparison of Urban and Rural Sub-Spaces of Traditional Settlements: Historical City of Mugla, Turkey
| dc.contributor.author | Timur, Barış Ali | |
| dc.contributor.author | Başaran, Tahsin | |
| dc.contributor.author | İpekoğlu, Başak | |
| dc.date.accessioned | 2023-07-27T19:50:00Z | |
| dc.date.available | 2023-07-27T19:50:00Z | |
| dc.date.issued | 2023 | |
| dc.description | Article; Early Access | en_US |
| dc.description.abstract | One of the significant processes that ensures realistic determination of the energy needs of historical buildings is case-specific definition of their local microclimatic conditions. Accordingly, the aim of this study is to determine differences for the parameters of temperature and humidity in urban and rural sub-settlements of the historical city, Mugla/Turkey. Study method consists of on-site measurements of these variables in sub-settlements for comparisons. As a result, it was identified urban zone shows heat island characteristics with warmer, drier, and more stable conditions; while rural sub-settlement remains cooler, more humid, and more erratic. In parallel, calculated extents of these differences demonstrate the significance and necessity of on-site measurements and consequential microclimatic zoning of historical cities as conservation/planning tools for responding to the thermal needs of architectural heritage. A key application of these processes would be the establishment of local databases of case-specific weather data to be used in thermal simulation assessments. | en_US |
| dc.description.sponsorship | This work was supported by B-type Scientific Research Project Funding of Izmir Institute of Technology (IZTECH) [2016IYTE66]. | en_US |
| dc.identifier.doi | 10.1080/15583058.2023.2208559 | |
| dc.identifier.issn | 1558-3058 | |
| dc.identifier.issn | 1558-3066 | |
| dc.identifier.scopus | 2-s2.0-85158908364 | |
| dc.identifier.uri | https://doi.org/10.1080/15583058.2023.2208559 | |
| dc.identifier.uri | https://hdl.handle.net/11147/13612 | |
| dc.language.iso | en | en_US |
| dc.publisher | Taylor & Francis | en_US |
| dc.relation | Geleneksel Yapıların Isıl Davranışları: Muğla Geleneksel Konutları | tr |
| dc.relation.ispartof | International Journal of Architectural Heritage | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Experimental measurements | en_US |
| dc.subject | Historical cities | en_US |
| dc.subject | Traditional buildings | en_US |
| dc.subject | Turkey | en_US |
| dc.subject | Urban heat Island | en_US |
| dc.title | On-Site Measurements of Temperature and Humidity Conditions for the Comparison of Urban and Rural Sub-Spaces of Traditional Settlements: Historical City of Mugla, Turkey | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| gdc.author.scopusid | 57368010600 | |
| gdc.author.scopusid | 6602221948 | |
| gdc.author.scopusid | 56617836200 | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C5 | |
| gdc.coar.access | metadata only access | |
| gdc.coar.type | text::journal::journal article | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | İzmir Institute of Technology. Conservation and Restoration of Cultural Heritage | en_US |
| gdc.description.department | İzmir Institute of Technology. Architecture | en_US |
| gdc.description.endpage | 848 | |
| gdc.description.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| gdc.description.scopusquality | Q1 | |
| gdc.description.startpage | 830 | |
| gdc.description.volume | 18 | |
| gdc.description.wosquality | Q2 | |
| gdc.identifier.openalex | W4367842516 | |
| gdc.identifier.wos | WOS:000980846500001 | |
| gdc.index.type | WoS | |
| gdc.index.type | Scopus | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 0.0 | |
| gdc.oaire.influence | 2.635068E-9 | |
| gdc.oaire.isgreen | false | |
| gdc.oaire.popularity | 2.588463E-9 | |
| gdc.oaire.publicfunded | false | |
| gdc.openalex.collaboration | National | |
| gdc.openalex.fwci | 0.16388203 | |
| gdc.openalex.normalizedpercentile | 0.4 | |
| gdc.opencitations.count | 0 | |
| gdc.plumx.mendeley | 16 | |
| gdc.plumx.scopuscites | 0 | |
| gdc.scopus.citedcount | 0 | |
| gdc.wos.citedcount | 1 | |
| relation.isAuthorOfPublication.latestForDiscovery | f128fa5f-fef6-460a-a17f-f78c43dc8c08 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 9af2b05f-28ac-4026-8abe-a4dfe192da5e |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- OnSite-Measurements.pdf
- Size:
- 18.06 MB
- Format:
- Adobe Portable Document Format