Investigation of the Reaction of Boron Oxide With Aluminium Powder and Method Development for Boron Determination in the Reaction Mixture

dc.contributor.advisor Özgen, Tamerkan
dc.contributor.author Demirsar, Yelda
dc.date.accessioned 2014-07-22T13:52:00Z
dc.date.available 2014-07-22T13:52:00Z
dc.date.issued 2007
dc.description Thesis (Master)--İzmir Institute of Technology, Chemistry, İzmir, 2007 en_US
dc.description Includes bibliographical references (leaves: 60-62) en_US
dc.description Text in English; Abstract: Turkish and English en_US
dc.description xi, 62 leaves en_US
dc.description.abstract In this study, a cheap method for the synthesis of elemental boron by the reduction of boron oxide with aluminum was investigated. However after various optimization studies, detectable boron amounts could not be found in the reaction mixtures by XRD and SEM-EDX analysis. Meanly aluminum borates were formed as products and these products were leached by 6 M HCl, however removel of borates could not be achieved. We think that the reason of this outcome is that we worked with simple experimental setup, therefore could not achieving the suitable experiment conditions and because of this we failed in the sythesis of boron. In the second part of the study, a new method for the direct determination of boron was investigated. 96 %pure boron and KBr were mixed and analyzed with Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS). No distinct differences for boron was observed in the DRIFT spectra. Then, different sample compositions were prepared with different amounts of boron and KBr. These samples were split as validation and calibration sets and their spectra were collected by DRIFTS. All collected spectral data were processed in a different computer where the data proccessing programs were installed. The genetic inverse least square (GILS) method was used inorder to generate calibration model. Results obtained showed that boron amounts could be directly determined with maximum 3-4 % error. Afterwards, same procedure was also tried for boron and boron oxide binary mixtures and boron, boron oxide and aluminum ternary mixtures. In the binary mixture, determination of boron could be successfully achieved, however boron oxide determination could not be achieved as good as boron determination. In the ternary mixture, better results were obtained compared to binary mixture. Finally, the method was tried with the original samples, but not very satisfactory results were obtained. We think this result is due to the malfunction of FTIR instrument and personal error in the preparation of similar samples. More sample preparation and measurement could not be achieved because the FTIR instrument is not functioning at present. en_US
dc.identifier.uri https://hdl.handle.net/11147/3636
dc.language.iso en en_US
dc.publisher İzmir Institute of Technolog en_US
dc.publisher Izmir Institute of Technology en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcc QD181.B1 D37 2007 en
dc.subject.lcsh Boron en
dc.subject.lcsh Alluminum en
dc.subject.lcsh Chemical reactions en
dc.subject.lcsh Fourien transform infrared spectroscopy en
dc.subject.lcsh Scanning electron microscopy en
dc.title Investigation of the Reaction of Boron Oxide With Aluminium Powder and Method Development for Boron Determination in the Reaction Mixture en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Demirsar, Yelda
gdc.coar.access open access
gdc.coar.type text::thesis::master thesis
gdc.description.department Thesis (Master)--İzmir Institute of Technology, Chemistry en_US
gdc.description.publicationcategory Tez en_US
gdc.description.scopusquality N/A
gdc.description.wosquality N/A
relation.isAuthorOfPublication.latestForDiscovery 40bf238b-3ad5-49d9-8caa-7670be39a817
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4011-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
T000628.pdf
Size:
1.05 MB
Format:
Adobe Portable Document Format
Description:
MasterThesis

License bundle

Now showing 1 - 1 of 1
Loading...
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: