Exergoeconomic analysis of plum drying in a heat pump conveyor dryer
| dc.contributor.author | Hepbaşlı, Arif | |
| dc.contributor.author | Çolak, Neslihan | |
| dc.contributor.author | Hancıoğlu, Ebru | |
| dc.contributor.author | İçier, Filiz | |
| dc.contributor.author | Erbay, Zafer | |
| dc.coverage.doi | 10.1080/07373937.2010.482843 | |
| dc.date.accessioned | 2016-12-21T07:35:30Z | |
| dc.date.available | 2016-12-21T07:35:30Z | |
| dc.date.issued | 2010 | |
| dc.description.abstract | In this study, plum slices were dried in a heat pump dryer designed and constructed in Ege University, Izmir, Turkey. Drying experiments were carried out at an air temperature range of 45-55°C. The performance of the dryer along with its main components were evaluated using an exergy analysis method. Exergy destruction and capital cost rates were used for the exergoeconomic analysis, which is based on the quantities exergy, cost, energy, and mass (EXCEM) method. Exergy destruction rates to capital cost values Rex were obtained to vary between 1.668 and 2.063 W/ USD at different drying air temperatures. Ren values were observed to range from 6.258 to 5.749 W/USD. Ren values decreased as the drying air temperature increased, contrary to Rex values. Ṙex and Ṙen values increased linearly with increasing temperature due to the loss, whereas Ṙen decreased due to the relatively higher energy utilization efficiency of the heat pump. In the compressor, Ṙen and Ṙex values decreased with the increase in the temperature contrary to the other components. Ṙex had the lowest value in the drying duct. However, in the compressor, expansion valve, and heat recovery, Ṙex values were found to be higher and should be improved in these units. © 2010 Taylor & Francis Group, LLC. | en_US |
| dc.description.sponsorship | TÜBİTAK project no. 106M482 | en_US |
| dc.identifier.citation | Hepbaşlı, A., Çolak, N., Hancıoğlu, E., İçier, F., and Erbay, Z. (2010). Exergoeconomic analysis of plum drying in a heat pump conveyor dryer. Drying Technology, 28(12), 1385-1395. doi:10.1080/07373937.2010.482843 | en_US |
| dc.identifier.doi | 10.1080/07373937.2010.482843 | en_US |
| dc.identifier.issn | 0737-3937 | |
| dc.identifier.issn | 0737-3937 | |
| dc.identifier.issn | 1532-2300 | |
| dc.identifier.scopus | 2-s2.0-78649460655 | |
| dc.identifier.uri | http://doi.org/10.1080/07373937.2010.482843 | |
| dc.identifier.uri | http://hdl.handle.net/11147/2640 | |
| dc.language.iso | en | en_US |
| dc.publisher | Taylor and Francis Ltd. | en_US |
| dc.relation.ispartof | Drying Technology | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Cost benefit analysis | en_US |
| dc.subject | Exergoeconomic analysis | en_US |
| dc.subject | Food drying | en_US |
| dc.subject | Heat pump dryer | en_US |
| dc.title | Exergoeconomic analysis of plum drying in a heat pump conveyor dryer | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| gdc.author.institutional | Hancıoğlu, Ebru | |
| gdc.bip.impulseclass | C4 | |
| gdc.bip.influenceclass | C4 | |
| gdc.bip.popularityclass | C4 | |
| gdc.coar.access | open access | |
| gdc.coar.type | text::journal::journal article | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | İzmir Institute of Technology. Geothermal Energy Research and Application Center (IZTECH JEOMER) | en_US |
| gdc.description.endpage | 1395 | en_US |
| gdc.description.issue | 12 | en_US |
| gdc.description.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| gdc.description.scopusquality | Q2 | |
| gdc.description.startpage | 1385 | en_US |
| gdc.description.volume | 28 | en_US |
| gdc.description.wosquality | Q2 | |
| gdc.identifier.openalex | W2135781526 | |
| gdc.identifier.wos | WOS:000284612300008 | |
| gdc.index.type | WoS | |
| gdc.index.type | Scopus | |
| gdc.oaire.accesstype | BRONZE | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.downloads | 1 | |
| gdc.oaire.impulse | 8.0 | |
| gdc.oaire.influence | 7.1140507E-9 | |
| gdc.oaire.isgreen | true | |
| gdc.oaire.keywords | Exergy destructions | |
| gdc.oaire.keywords | Heat pumps | |
| gdc.oaire.keywords | Energy utilization | |
| gdc.oaire.keywords | Heat pump systems | |
| gdc.oaire.keywords | Air temperature | |
| gdc.oaire.keywords | Pumps | |
| gdc.oaire.keywords | Atmospheric temperature | |
| gdc.oaire.keywords | Cost benefit analysis | |
| gdc.oaire.keywords | Curing | |
| gdc.oaire.keywords | Exergy | |
| gdc.oaire.keywords | Drying | |
| gdc.oaire.keywords | Dryers (equipment) | |
| gdc.oaire.keywords | 621 | |
| gdc.oaire.keywords | Exergy Analysis | |
| gdc.oaire.keywords | Exergoeconomic analysis; Food drying; Heat pump dryer | |
| gdc.oaire.keywords | Drying air | |
| gdc.oaire.keywords | 620 | |
| gdc.oaire.keywords | Energy utilization efficiency | |
| gdc.oaire.keywords | Heat pump dryer | |
| gdc.oaire.keywords | Food drying | |
| gdc.oaire.keywords | Main component | |
| gdc.oaire.keywords | Expansion valves | |
| gdc.oaire.keywords | Heat recovery | |
| gdc.oaire.keywords | Exergoeconomic analysis | |
| gdc.oaire.keywords | Waste heat | |
| gdc.oaire.keywords | Capital costs | |
| gdc.oaire.keywords | Compressors | |
| gdc.oaire.popularity | 2.041057E-8 | |
| gdc.oaire.publicfunded | false | |
| gdc.oaire.sciencefields | 02 engineering and technology | |
| gdc.oaire.sciencefields | 0202 electrical engineering, electronic engineering, information engineering | |
| gdc.oaire.views | 4 | |
| gdc.openalex.collaboration | International | |
| gdc.openalex.fwci | 5.03917742 | |
| gdc.openalex.normalizedpercentile | 0.95 | |
| gdc.openalex.toppercent | TOP 10% | |
| gdc.opencitations.count | 46 | |
| gdc.plumx.crossrefcites | 21 | |
| gdc.plumx.mendeley | 59 | |
| gdc.plumx.scopuscites | 50 | |
| gdc.scopus.citedcount | 50 | |
| gdc.wos.citedcount | 50 | |
| relation.isAuthorOfPublication.latestForDiscovery | 6d1c1afe-5ed3-4775-9d60-b3033f56bfa4 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 9af2b05f-28ac-4003-8abe-a4dfe192da5e |