Indoor Air Quality in Chemical Laboratories
| dc.contributor.author | Ugranlı, Tuğba | |
| dc.contributor.author | Güngörmüş, Elif | |
| dc.contributor.author | Sofuoğlu, Aysun | |
| dc.contributor.author | Sofuoğlu, Sait Cemil | |
| dc.coverage.doi | 10.1016/bs.coac.2016.04.007 | |
| dc.date.accessioned | 2018-03-22T12:53:55Z | |
| dc.date.available | 2018-03-22T12:53:55Z | |
| dc.date.issued | 2016 | |
| dc.description.abstract | Chemical laboratories are special microenvironments, in which many pollutants may be found because of the large range and number of chemicals that can be used, while concentrations of some specific ones may relatively be elevated due to high source strengths depending on the type and the number of experiments conducted and the number of people working in the laboratory. Laboratories can be considered as public places for the students whereas they are occupational microenvironments for their staff (technicians, specialists and teaching/research assistants). Hence, laboratory indoor air quality (IAQ) is of importance due to chronic, toxic and carcinogenic health risks for the staff in addition to possible acute effects for both staff and students. This chapter presents background information regarding pertinent indoor air pollutants, factors that determine their concentrations, indoor environmental comfort, a review of the literature on indoor environmental quality in chemical laboratories and measures of IAQ management. | en_US |
| dc.identifier.citation | Ugranlı, T., Güngörmüş, E., Sofuoğlu, A., and Sofuoğlu, S. C. (2016). Indoor air quality in chemical laboratories. Comprehensive Analytical Chemistry, 73, 859-878. doi:10.1016/bs.coac.2016.04.007 | en_US |
| dc.identifier.doi | 10.1016/bs.coac.2016.04.007 | |
| dc.identifier.doi | 10.1016/bs.coac.2016.04.007 | en_US |
| dc.identifier.issn | 0166-526X | |
| dc.identifier.scopus | 2-s2.0-84973515382 | |
| dc.identifier.uri | http://doi.org/10.1016/bs.coac.2016.04.007 | |
| dc.identifier.uri | https://hdl.handle.net/11147/6834 | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier Ltd. | en_US |
| dc.relation.ispartof | Comprehensive Analytical Chemistry | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Indoor air quality | en_US |
| dc.subject | Indoor environmental comfort | en_US |
| dc.subject | Laboratory | en_US |
| dc.subject | Indoor environmental quality | en_US |
| dc.subject | Literature on laboratory IAQ | en_US |
| dc.title | Indoor Air Quality in Chemical Laboratories | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| gdc.author.institutional | Ugranlı, Tuğba | |
| gdc.author.institutional | Güngörmüş, Elif | |
| gdc.author.institutional | Sofuoğlu, Aysun | |
| gdc.author.institutional | Sofuoğlu, Sait Cemil | |
| gdc.author.yokid | 115933 | |
| gdc.author.yokid | 27717 | |
| gdc.author.yokid | 59409 | |
| gdc.bip.impulseclass | C5 | |
| gdc.bip.influenceclass | C5 | |
| gdc.bip.popularityclass | C4 | |
| gdc.coar.access | open access | |
| gdc.coar.type | text::journal::journal article | |
| gdc.collaboration.industrial | false | |
| gdc.description.department | İzmir Institute of Technology. Chemical Engineering | en_US |
| gdc.description.endpage | 878 | en_US |
| gdc.description.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| gdc.description.scopusquality | Q3 | |
| gdc.description.startpage | 859 | en_US |
| gdc.description.volume | 73 | en_US |
| gdc.description.wosquality | N/A | |
| gdc.identifier.openalex | W2508179022 | |
| gdc.identifier.wos | WOS:000404661300034 | |
| gdc.index.type | WoS | |
| gdc.index.type | Scopus | |
| gdc.oaire.diamondjournal | false | |
| gdc.oaire.impulse | 1.0 | |
| gdc.oaire.influence | 3.1055325E-9 | |
| gdc.oaire.isgreen | true | |
| gdc.oaire.keywords | Indoor environmental quality | |
| gdc.oaire.keywords | Indoor environmental comfort | |
| gdc.oaire.keywords | Literature on laboratory IAQ | |
| gdc.oaire.keywords | Laboratory | |
| gdc.oaire.keywords | Indoor air quality | |
| gdc.oaire.popularity | 8.443656E-9 | |
| gdc.oaire.publicfunded | false | |
| gdc.oaire.sciencefields | 02 engineering and technology | |
| gdc.oaire.sciencefields | 01 natural sciences | |
| gdc.oaire.sciencefields | 0103 physical sciences | |
| gdc.oaire.sciencefields | 0210 nano-technology | |
| gdc.openalex.collaboration | National | |
| gdc.openalex.fwci | 2.16007714 | |
| gdc.openalex.normalizedpercentile | 0.83 | |
| gdc.openalex.toppercent | TOP 10% | |
| gdc.opencitations.count | 10 | |
| gdc.plumx.crossrefcites | 1 | |
| gdc.plumx.mendeley | 56 | |
| gdc.plumx.scopuscites | 9 | |
| gdc.scopus.citedcount | 9 | |
| gdc.wos.citedcount | 8 | |
| relation.isAuthorOfPublication.latestForDiscovery | 6865e229-4cc9-4470-ac9d-d377dd8f7f5d | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 9af2b05f-28ac-4021-8abe-a4dfe192da5e |
