Impact of Thermal Mass Oriented Measures Over CO2 Emissions of a Thermally Insulated Low-Rise Apartment Building in Izmir, Turkey

dc.contributor.author Gercek, Mumine
dc.contributor.author Arsan, Zeynep Durmus
dc.date.accessioned 2025-07-25T16:54:57Z
dc.date.available 2025-07-25T16:54:57Z
dc.date.issued 2014
dc.description.abstract Climate change has drawn the attention of many researchers and practitioners to focus on the methods to address the challenges in achieving low-carbon buildings and cities and in future developments. Nevertheless, few studies have explored the impacts of thermal mass applications for the lowest carbon emissions of building operational energy consumption. A comparative study of CO2 emissions due to different wall and floor compositions is presented in accordance with their lifespans for a hot-humid climate site. Aim of this study is to examine the relation between the energy oriented operations and carbon emissions of the building. Firstly, an existing low-rise building in Izmir is selected, then modelled in the dynamic simulation model software DesignBuilder v4 by synchronizing drawings with basic operational principles of the program. Furthermore, various influence factors of building envelope thermal characteristics are selected as follows: type, location, thickness and thermal specifications of materials used by keeping thermal conductivity value constant. At the end, the research presents remarkable influence of thermal mass oriented measures on reducing energy demands and carbon footprints. en_US
dc.identifier.issn 2147-9380
dc.identifier.uri https://hdl.handle.net/11147/15786
dc.language.iso en en_US
dc.publisher Selcuk Univ en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject CO2 Emission en_US
dc.subject Thermal Mass en_US
dc.subject Energy Efficiency en_US
dc.subject Housing en_US
dc.title Impact of Thermal Mass Oriented Measures Over CO2 Emissions of a Thermally Insulated Low-Rise Apartment Building in Izmir, Turkey en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.wosid Gercek, Mumine/Kal-8352-2024
gdc.author.wosid Arsan, Zeynep/I-1769-2018
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department İzmir Institute of Technology en_US
gdc.description.departmenttemp [Gercek, Mumine; Arsan, Zeynep Durmus] Izmir Inst Technol, Dept Architecture, Izmir, Turkey en_US
gdc.description.endpage 72 en_US
gdc.description.issue 2 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality N/A
gdc.description.startpage 59 en_US
gdc.description.volume 2 en_US
gdc.description.woscitationindex Emerging Sources Citation Index
gdc.description.wosquality N/A
gdc.identifier.wos WOS:000453088500005
gdc.index.type WoS
gdc.wos.citedcount 2
relation.isAuthorOfPublication.latestForDiscovery 401fccd6-20bd-41d0-9539-3dd159bbf105
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4026-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
Impact of Thermal Mass Oriented Measures Over CO2 Emissions Of a Thermally Insulated Lowrise Apartment Building in Izmir, Turkey[#103986]-88949.pdf
Size:
1.55 MB
Format:
Adobe Portable Document Format
Description:
Article