Effect of Infill Walls on the Drift Behavior of Reinforced Concrete Frames Subjected To Lateral-Load Reversals

Loading...

Date

Authors

Dönmez, Cemalettin

Journal Title

Journal ISSN

Volume Title

Open Access Color

BRONZE

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Top 10%
Popularity
Average

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Four-story, single-bay, 1/5 scaled reinforced concrete frames were tested with and without infill walls. Frames were subjected to pseudo-static cyclic loading. In addition, impact hammer measurements were made to obtain the natural frequencies and modal shapes at certain drift levels. It was observed that infill walls cause major changes on both the stiffness and the drift behavior of the frames. Effect of observed changes can be either advantageous or disadvantageous depending on failure mode. Results showed that the distribution of drift that is based on the mode shapes has higher local concentrations than the distribution observed under forced static conditions.

Description

Keywords

Infill, Cyclic load, Mode shapes, Concretes, Inter-story drift ratios, Reinforced concrete, Mode shapes, Reinforced concrete, Cyclic load, Infill, Concretes, Inter-story drift ratios

Fields of Science

0211 other engineering and technologies, 02 engineering and technology, 0201 civil engineering

Citation

Dönmez, C., and Çankaya, M. A. (2013). Effect of infill walls on the drift behavior of reinforced concrete frames subjected to lateral-load reversals. Journal of Earthquake Engineering, 17(5), 611-636. doi:10.1080/13632469.2013.768562

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
2

Volume

17

Issue

5

Start Page

611

End Page

636
PlumX Metrics
Citations

Scopus : 4

Captures

Mendeley Readers : 20

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.6128505

Sustainable Development Goals