Experimental Structural Stiffness Analysis of a Surgical Haptic Master Device Manipulator

Loading...

Date

Authors

Görgülü, İbrahimcan
Dede, Mehmet İsmet Can

Journal Title

Journal ISSN

Volume Title

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

This paper deals with haptic devices for master-slave telesurgical applications. Namely, a stiffness model fitting methodology and its fine-tuning are proposed based on experimental results. In particular, the proposed procedure is based on virtual joint structural stiffness modeling to be applied in time-efficient compliance compensation strategies. A specific case study is discussed by referring to the HISS haptic device that has been developed and built at Izmir Institute of Technology. Two different experimental setups are designed for stiffness evaluation tests. Experimental results are discussed to demonstrate their implementation in the proposed methodology for the fine-tuning of stiffness model.

Description

Keywords

Structural stiffness

Fields of Science

0209 industrial biotechnology, 02 engineering and technology

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
2

Volume

15

Issue

1

Start Page

End Page

PlumX Metrics
Citations

CrossRef : 2

Scopus : 3

Captures

Mendeley Readers : 3

SCOPUS™ Citations

3

checked on Apr 30, 2026

Web of Science™ Citations

3

checked on Apr 30, 2026

Page Views

5878

checked on Apr 30, 2026

Downloads

168

checked on Apr 30, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.35164953

Sustainable Development Goals