Air Leakage Detection in Various Cross Sectioned Air Ducts and Research on Manufacturing Methods for Airtightness

dc.contributor.advisor Özerdem, Mehmet Bariş
dc.contributor.author Aydın, Çiğdem
dc.date.accessioned 2014-07-22T13:51:18Z
dc.date.available 2014-07-22T13:51:18Z
dc.date.issued 2004
dc.description Thesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2004 en_US
dc.description Includes bibliographical references (leaves: 65-67) en_US
dc.description Text in English; Abstract: Turkish and English en_US
dc.description xv,108 leaves en_US
dc.description.abstract Air ducts and related equipments are important components of climate and ventilation systems in order to distribute clean air, necessary for the occupied space, to whole system and to control thermal comfort. Despite of Turkish standards on air duct are present, studies on energy consumption associated with air leakage are very rare in Turkey, on the contrary to many developed countries. In this study, the subject of preventing energy losses related to the leakage, which causes inefficient working condition, has been investigated. Firstly, air duct system and quality requirements have been explained and the main standards have been analyzed for airtightness of air distribution systems, as well. Secondly, duct system measurements have been conducted by choosing two different approaches. One approach covers leakage calculation of a single duct by using European Standard called Eurovent, whereas the other one divides the system into single sections and uses the Power Law Model for calculation of leakage occurred in each section.Single duct leakage measurements were made on 300 mm and 1000 mm diameter circular ducts and 300 mm by 250 mm and 1000 mm by 500 mm flanged joint rectangular ducts for positive internal pressures. Test results showed that duct leakage depends on the method of duct fabrication, method of sealing, workmanship and static pressure differential. Furthermore, calculated leakage factors were under the allowable leakage limits in classification .C. for rectangular and circular ducts that were produced by Venco A.Ş. Comparing rectangular to circular ducts both had the same length of seam and surface area; the leakage from circular ducts was less than 80% from rectangular ducts. The air leakage from all test ducts, with the same lock seam type, decreases, whereas the surface area increases.Branched duct leakage measurements were made on 300 mm and 630 mm diameter circular ducts and 300 mm by 200 mm and 500 mm by 300 mm rectangular ducts and also air distribution system for positive internal pressures. Test results showed that fittings in a system cause sudden changes in static pressure; therefore, duct leakage depends on fitting locations. The leakage rate in Spiro sealed system was less than 5% Trelleborg sealed system. The leakage measured in this study showed that seam leakage accounts from 14% to 20% of the total in the two rectangular ducts and from 8% to 13% for the round ducts with Pittsburgh and Spiral lock seams. These data show that the joints are the major source of duct leakage. Improvement in duct construction leading to duct systems with less leakage will need to focus on better joints. Keywords: airtightness duct system, air duct leakage, duct leakage model, ductwork test procedure and methods. en_US
dc.identifier.uri https://hdl.handle.net/11147/3313
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en_US
dc.publisher Izmir Institute of Technology en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcc TH7683.D8 .A97 2004 en
dc.subject.lcsh Air ducts en
dc.subject.lcsh Air ducts--Standards en
dc.title Air Leakage Detection in Various Cross Sectioned Air Ducts and Research on Manufacturing Methods for Airtightness en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Aydın, Çiğdem
gdc.coar.access open access
gdc.coar.type text::thesis::master thesis
gdc.description.department Thesis (Master)--İzmir Institute of Technology, Mechanical Engineering en_US
gdc.description.publicationcategory Tez en_US
gdc.description.scopusquality N/A
gdc.description.wosquality N/A
relation.isAuthorOfPublication.latestForDiscovery ed35182b-6ea4-4e9c-b5e2-e82f75ab064f
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4022-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
T000515.pdf
Size:
24.79 MB
Format:
Adobe Portable Document Format
Description:
MasterThesis

License bundle

Now showing 1 - 1 of 1
Loading...
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: