Mr-Guided Focused Ultrasound Application for Moving Target Tumor Ablation in Abdominal Area: Coil Selection

Loading...

Date

Journal Title

Journal ISSN

Volume Title

Open Access Color

BRONZE

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Background Magnetic Resonance Imaging (MRI)-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive thermal ablation method utilizing high-intensity focused ultrasound (HI-FU) energy for tissue ablation under MRI with real-time thermal mapping. Ablating to a dynamic target as in the liver is very challenging, requiring approval. A novel quality-assured liver tumor ablation system has been proposed for clinics. The paper reports the evaluation of conventional and new MR-receiving coils. Purpose To evaluate the suitability of MR coils as part of the MRgFUS treatment system for liver, while simulating breathing motion in pre-clinical settings. Material and Methods The novel software communicates with the MR scanner and the transducer. To monitor the temperature via proton resonance frequency (PRF) methodology echo planar imaging (EPI) sequence was used while the algorithms of static, static and dynamic tracking were tested with sonications of 100 W for 30 s on tissue-mimicking phantoms. Different coil sets were used to assess the performance of the system for fitness for dynamic thermometry. Finally, in vivo experiments were performed over a porcine model. Results Single-loop four-channel Duoflex and Gem coils provided adequate signal-to-noise ratio and contrast with consistent thermal readings. Body array coils showed severe loss of signal in dynamic cases since the integration of tracking algorithm causes low efficiency. Conclusion Body array coils are unsuitable for MRgFUS of the liver due to signal loss. The dedicated coil set with a single loop around the FUS transducer combined with four-channel arrays might be the best option for liver treatment using dynamic MRgFUS applications.

Description

Keywords

Coils, Magnetic resonance thermometry, Tracking, Echo planar imaging, Magnetic resonance imaging, CE marking, Validation, Verification, Swine, 610, magnetic resonance-guided focused-ultrasounds surgery, Magnetic Resonance Imaging, Interventional, magnetic resonance-guided focused-ultrasound surgery, /dk/atira/pure/subjectarea/asjc/2700/2741, CE marking, /dk/atira/pure/subjectarea/asjc/3600/3614, Echo planar imaging, Abdomen, Animals, Humans, validation, name=Radiological and Ultrasound Technology, Echo-Planar Imaging, Phantoms, Imaging, Tracking, Liver Neoplasms, Verification, Coils, tracking, Disease Models, Animal, Liver, name=Radiology Nuclear Medicine and imaging, High-Intensity Focused Ultrasound Ablation, echo planar imaging, verification, Magnetic resonance thermometry

Fields of Science

0206 medical engineering, 02 engineering and technology, 03 medical and health sciences, 0302 clinical medicine

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
N/A

Volume

62

Issue

Start Page

3

End Page

11
PlumX Metrics
Citations

Scopus : 2

PubMed : 1

Captures

Mendeley Readers : 16

Web of Science™ Citations

2

checked on Apr 27, 2026

Page Views

2711

checked on Apr 27, 2026

Downloads

154

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.0

Sustainable Development Goals

SDG data is not available