Applicability of a Prismatic Panel To Optimize Window Size and Depth of a South-Facing Room for a Better Daylight Performance

dc.contributor.author Köse, Büşra
dc.contributor.author Kazanasmaz, Zehra Tuğçe
dc.coverage.doi 10.33383/2019-038
dc.date.accessioned 2021-01-24T18:33:05Z
dc.date.available 2021-01-24T18:33:05Z
dc.date.issued 2020
dc.description.abstract This study examines the performance of attached prismatic panels, which have shading capability, in a side-lit deep plan room to find out the least possible WWR value in relation to room depth satisfying the required daylight availability. The methodology is based on simulating a base model in Relux and testing it with alternative models composed of incrementally defined WWR and room depth values. In accordance with minimum IES requirements, the most satisfying sDA value was found to be 48.54 % in a room of 12 m depth with 67 % WWR. An sDA of 51.59 % and 59.26 % was achieved in a room of 9m depth with 43 % WWR and 6m depth with 30 % WWR, respectively. The least ASE values were obtained with the least WWR alternative of 30 % in all room depths. This study presents a new approach with the consideration of innovative daylight redirecting systems to propose revisions for the requirements mentioned in standards about daylight in buildings but based on conventional fenestration systems. © 2020, LLC Editorial of Journal ""Light Technik"". All rights reserved. en_US
dc.identifier.doi 10.33383/2019-038 en_US
dc.identifier.issn 0236-2945
dc.identifier.issn 1068-9761
dc.identifier.issn 2541-9935
dc.identifier.scopus 2-s2.0-85095443291
dc.identifier.uri https://doi.org/10.33383/2019-038
dc.identifier.uri https://hdl.handle.net/11147/10225
dc.language.iso en en_US
dc.publisher Znack Publishing House en_US
dc.relation.ispartof Light and Engineering en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Daylight en_US
dc.subject Prismatic panels en_US
dc.subject Room depth en_US
dc.subject Windows en_US
dc.title Applicability of a Prismatic Panel To Optimize Window Size and Depth of a South-Facing Room for a Better Daylight Performance en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.institutional Köşe, Büşra
gdc.author.institutional Kazanasmaz, Zehra Tuğçe
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department İzmir Institute of Technology. Architecture en_US
gdc.description.endpage 67 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q4
gdc.description.startpage 63 en_US
gdc.description.volume 28 en_US
gdc.description.wosquality Q4
gdc.identifier.openalex W3110956457
gdc.identifier.wos WOS:000620643000004
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.accesstype BRONZE
gdc.oaire.diamondjournal false
gdc.oaire.impulse 3.0
gdc.oaire.influence 2.786456E-9
gdc.oaire.isgreen false
gdc.oaire.popularity 4.4844897E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0211 other engineering and technologies
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.collaboration International
gdc.openalex.fwci 0.69132233
gdc.openalex.normalizedpercentile 0.7
gdc.opencitations.count 2
gdc.plumx.mendeley 4
gdc.plumx.scopuscites 7
gdc.scopus.citedcount 7
gdc.wos.citedcount 7
relation.isAuthorOfPublication.latestForDiscovery 199bb65d-4746-4276-bc6a-a4648af67d89
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4026-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
2019_kose_kmaz_LE_rev.pdf
Size:
603.95 KB
Format:
Adobe Portable Document Format
Description:
Article (Makale)