Assessment of Different Nanofiltration and Reverse Osmosis Membranes for Simultaneous Removal of Arsenic and Boron From Spent Geothermal Water

Loading...

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 1%
Influence
Top 10%
Popularity
Top 1%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

One of the factors that determine agricultural crops’ yield is the quality of water used during irrigation. In this study, we assessed the usability of spent geothermal water for agricultural irrigation after membrane treatment. Preliminary membrane tests were conducted on a laboratory-scale set up followed by mini-pilot scale tests in a geothermal heating center. In part I, three commercially available membranes (XLE BWRO, NF90, and Osmonics CK- NF) were tested using a cross-flow flat-sheet membrane testing unit (Sepa CF II, GE-Osmonics) under constant applied pressure of 20 bar. In part II, different spiral wound membranes (TR-NE90-NF, TR-BE-BW, and BW30) other than the ones used in laboratory tests were employed for the mini-pilot scale studies in a continuous mode. Water recovery and applied pressure were maintained constant at 60% and 12 bar, respectively. Performances of the membranes were assessed in terms of the permeate flux, boron and arsenic removals. In laboratory tests, the permeate fluxes were measured as 94.3, 87.9, and 64.3 L m?2 h?1 for XLE BWRO, CK-NF and NF90 membranes, respectively. The arsenic removals were found as 99.0%, 87.5% and 83.6% while the boron removals were 56.8%, 54.2%, and 26.1% for XLE BWRO, NF90 and CK-NF membranes, respectively. In field tests, permeate fluxes were 49.9, 26.8 and 24.0 L m?2 h?1 for TR-NE90-NF, BW30-RO and TR-BE-BW membranes, respectively. Boron removals were calculated as 49.9%, 44.1% and 40.7% for TR-BE-BW, TR-NE90-NF and BW30-RO membranes, respectively. Removal efficiencies of arsenic in mini-pilot scale membrane tests were all over 90%. Quality of the permeate water produced was suitable for irrigation in terms of the electrical conductivity (EC) and the total dissolved solids (TDS) for all tested membranes with respect to guidelines set by the Turkish Ministry of Environment and Urbanisation (TMEU). However, XLE BWRO, CK-NF and NF90 membranes failed to meet the required limits for irrigation in terms of boron and arsenic concentrations in the product water. The permeate streams of TR-BE-BW, TR-NE90-NF and BW30-RO membranes complied with the irrigation water standards in terms of EC, TDS and arsenic concentration while boron concentration remained above the allowable limit. © 2020 Elsevier B.V.

Description

Keywords

Arsenic, Boron, Geothermal water, Irrigation water, Membrane, Nanofiltration (NF), Reverse osmosis (RO), Nanofiltration (NF), Reverse osmosis (RO), Membrane, Irrigation water, Geothermal water, Arsenic, Boron

Fields of Science

02 engineering and technology, 0204 chemical engineering, 01 natural sciences, 0105 earth and related environmental sciences

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
46

Volume

405

Issue

Start Page

End Page

PlumX Metrics
Citations

CrossRef : 52

Scopus : 60

PubMed : 2

Captures

Mendeley Readers : 99

SCOPUS™ Citations

59

checked on Apr 29, 2026

Web of Science™ Citations

58

checked on Apr 29, 2026

Page Views

1923

checked on Apr 29, 2026

Downloads

195

checked on Apr 29, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
3.64779568

Sustainable Development Goals

CLEAN WATER AND SANITATION6
CLEAN WATER AND SANITATION