Development of Inductively Coupled Plasma Spectroscopic Methods for the Determination of Metals in Beluga (delphinapterus Leucas) and Pygmy Sperm (kogia Breviceps) Whale Liver Samples

dc.contributor.advisor Eanes, Ritchie C.
dc.contributor.author Parlayan, Filiz
dc.date.accessioned 2014-07-22T13:51:12Z
dc.date.available 2014-07-22T13:51:12Z
dc.date.issued 2005
dc.description Thesis (Master)--İzmir Institute of Technology, Chemistry, İzmir, 2005 en_US
dc.description Includes bibliographical references (leaves: 111-120) en_US
dc.description Text in English; Abstract: Turkish and English en_US
dc.description xiii, 137 leaves en_US
dc.description.abstract Inductively couple plasma optical emission spectrometry (ICP-OES) is widely used to monitor elements in biological samples from marine organisms for ecological evaluations. Matrix effects (particularly those related to acid and salt type and concentrations) can present a barrier to the applicability of this instrumental method. To have a better understanding of these effects and to choose a suitable internal standard to correct for the signal variations, a procedure based on Principal Component Analysis (PCA) of the data from an axial-mode ICP-OES instrument with sequential detection was performed. Different from other published studies, it was found that ionic lines were more affected by matrix changes. Elements with high ionization energies and energy sums such as Cd and Zn showed a significant change for signal intensities and calculated concentrations due to the presence of acid, salt, and multielement matrix effects. It was observed that acid has a higher influence on the analyte signal as compared to the "salt-only" case. Furthermore, when several interfering elements were present in the sample, the matrix effect was either enhanced or reduced when compared with a solution containing only a single interfering element. Applicability of the proposed technique for the analysis of whale liver homogenate NIST certified material was investigated. The values of the corrected concentrations were in good agreement with the certified values, confirming the capabilities of the selected internal standards for compensation of matrix effects. en_US
dc.identifier.uri https://hdl.handle.net/11147/3262
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcc QD96.I47 .P22 2005 en
dc.subject.lcsh Inductively coupled plasma spectrometry en
dc.subject.lcsh Plasma spectroscopy en
dc.subject.lcsh Matrix effect en
dc.title Development of Inductively Coupled Plasma Spectroscopic Methods for the Determination of Metals in Beluga (delphinapterus Leucas) and Pygmy Sperm (kogia Breviceps) Whale Liver Samples en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Parlayan, Filiz
gdc.coar.access open access
gdc.coar.type text::thesis::master thesis
gdc.description.department Thesis (Master)--İzmir Institute of Technology, Chemistry en_US
gdc.description.publicationcategory Tez en_US
gdc.description.scopusquality N/A
gdc.description.wosquality N/A
relation.isAuthorOfPublication.latestForDiscovery a2542b9c-9114-478e-9565-8ffe9a462d30
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4011-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
T000399.pdf
Size:
1.92 MB
Format:
Adobe Portable Document Format
Description:
MasterThesis

License bundle

Now showing 1 - 1 of 1
Loading...
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: