Evaluation of the Performance of a Household Refrigerator Using a Variable Speed Compressor With 1d Simulations

Loading...

Date

2013

Journal Title

Journal ISSN

Volume Title

Publisher

Izmir Institute of Technology

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Inefficient use of electricity is considered as an indirect contributor to the emission of greenhouse gases into the atmosphere. One way to reduce these emissions is to improve the energy conversion efficiencies of the electric equipment. The household refrigerators are designed to satisfy the maximum cooling load to which they are exposed. However, they operate under part load conditions for most of their lifetime. In the literature, some refrigeration capacity control methods are presented such as on/off control, hot gas bypass, evaporator temperature control, clearance volume control, multiple compressor control, cylinder unloading and the variable speed compressor (VSC) control. VSC control has been reported to be the most useful refrigeration capacity modulation method in many studies in terms of its ability to match the refrigeration capacity to the instantaneous cooling load while at the same time decreasing the average and instantaneous power requirements, therefore the total energy consumption (EC) of a refrigerator. In this thesis, three different VSC control algorithms are studied utilizing the 1D model of a commercial household refrigerator. The ECs and the cooling performances are compared with those of the standard on/off compressor control algorithm at the nominal frequency of 50 Hertz (Hz). Temperature management of the cold store and the freezer compartments are investigated in detail, considering the regulations on household refrigerating appliances, characteristics and test methods declared by the British Standards Institute. In addition to the standard EC calculations during the steady state operating conditions, the performances of the VSC control algorithms are evaluated under transient cooling load conditions, as well. It is shown that using a VSC control algorithm to modulate the refrigeration capacity of a refrigerator, when the refrigerator operates under part load conditions, could provide considerable energy savings.

Description

Thesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2013
Includes bibliographical references (leaves: 104-106)
Text in English; Abstract: Turkish and English
xii, 106 leaves
Full text release delayed at author's request until 2015.07.10

Keywords

Energy saving

Fields of Science

Citation

WoS Q

N/A

Scopus Q

N/A

Source

Volume

Issue

Start Page

End Page

Page Views

711

checked on Apr 27, 2026

Downloads

783

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™

Sustainable Development Goals

AFFORDABLE AND CLEAN ENERGY7
AFFORDABLE AND CLEAN ENERGY
DECENT WORK AND ECONOMIC GROWTH8
DECENT WORK AND ECONOMIC GROWTH
INDUSTRY, INNOVATION AND INFRASTRUCTURE9
INDUSTRY, INNOVATION AND INFRASTRUCTURE
RESPONSIBLE CONSUMPTION AND PRODUCTION12
RESPONSIBLE CONSUMPTION AND PRODUCTION
CLIMATE ACTION13
CLIMATE ACTION