Wearable Motion Capture System Evaluation for Biomechanical Studies for Hip Joints

Loading...

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Human motion capture (MOCAP) systems are vital while determining the loads occurring at the joints. Most of the clinical MOCAP systems are very costly, requiring investment and infrastructure. Therefore, alternative technologies are in demand. In this study, a novel markerless wearable MOCAP system was assessed for its compatibility with a biomechanical modeling software. To collect evidence, experiments were designed in two stages for quantifying the range of motion (ROM) of the hip joint, in vitro and in vivo. Three constrained single-plane motions-abduction/adduction, flexion/extension, and internal/external rotation movements of the active leg-were analyzed. The data were collected from 14 healthy volunteers, using the wearable system and a medical grade optoelectronic MOCAP system simultaneously and compared against. For the in vitro study, the root-mean-square error (RMSE) for the abduction/adduction motion of the hip joint was calculated as 0.11deg/0.30deg and 0.11deg/0.09deg, respectively, for the wearable and the opto-electronic system. The in vivo Bland-Altman plots showed that the two system data are comparable. The simulation software is found compatible to run the simulations in offline mode. The wearable system could be utilized in the field of biomechanics software for running the kinetic simulations. The results demonstrated that the wearable system could be an alternative in the field of biomechanics based on the evidence collected.

Description

Keywords

MOCAP, Motion analysis, Human motion capture systems, Lower body, Wearable MOCAP, Verification, ISO13485, Male, Adult, Movement, Biomechanical Phenomena, Wearable Electronic Devices, Young Adult, Motion Capture, Humans, Hip Joint, Female, Range of Motion, Articular, Mechanical Phenomena

Fields of Science

0206 medical engineering, 02 engineering and technology, 03 medical and health sciences, 0302 clinical medicine

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
16

Volume

143

Issue

4

Start Page

End Page

PlumX Metrics
Citations

Scopus : 24

PubMed : 6

Captures

Mendeley Readers : 40

SCOPUS™ Citations

23

checked on Apr 28, 2026

Web of Science™ Citations

21

checked on Apr 28, 2026

Page Views

2682

checked on Apr 28, 2026

Downloads

175

checked on Apr 28, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
2.21624672

Sustainable Development Goals

INDUSTRY, INNOVATION AND INFRASTRUCTURE9
INDUSTRY, INNOVATION AND INFRASTRUCTURE