The Computational Approach To Predicting Wear: Comparison of Wear Performance of Cfr-Peek and Xlpe Liners in Total Hip Replacement

dc.contributor.author Alpkaya, Alican Tuncay
dc.contributor.author Mihçin, Şenay
dc.date.accessioned 2023-01-19T06:41:43Z
dc.date.available 2023-01-19T06:41:43Z
dc.date.issued 2022
dc.description.abstract Wear on articulating bearing surfaces is a key factor causing revision in total hip replacement (THR). Wear debris that releases particles from bearing surfaces might result in adverse soft tissue reactions requiring revision surgeries. In this study, a comprehensive computational wear model based on the Archard wear equation was performed to investigate the wear performance under a three-dimensional (3D) physiological gait cycle, mimicking a normal walking condition (5 million cycles). The study shows that the accuracy of the model is highly dependent on the mesh convergence, the wear fraction, and the scaling factor. The simulations were run to provide a vast amount of detail for the reproducibility of the work. Cobalt chromium (CoCr) on cross-linked polyethylene (XLPE) and CoCr on carbon-fiber-reinforced polyether ether ketone (CFR-PEEK) prototype models were created in silico. The volumetric wear rates for CoCr-on-XLPE were calculated as 0.2989 (Formula presented.) for CoCr head and 21.0271 (Formula presented.) for XLPE liner, while for CoCr-on-CFR-PEEK they were 0.3484 (Formula presented.) for CoCr head and 1.8476 (Formula presented.) for CFR-PEEK liner. When compared to in vivo and in vitro studies, the wear patterns of these two prototypes are consistent with those of the conventional polyethylene liners in the literature. Although the volumetric wear rate of the CFR-PEEK liner is about 11 times lower than the counterpart of XLPE in MoP implants, the wear rate of CoCr was higher when compared to its use with XLPE. Therefore, CFR-PEEK articulating against orthopa\edic metals may not be as good an alternative as XLPE, due to higher indicative metallic wear. This detailed computational wear modeling methodology could be utilized in design improvements of implants. en_US
dc.identifier.doi 10.1080/10402004.2022.2140727
dc.identifier.issn 1040-2004 en_US
dc.identifier.issn 1040-2004
dc.identifier.issn 1547-397X
dc.identifier.scopus 2-s2.0-85144145526
dc.identifier.uri https://doi.org/10.1080/10402004.2022.2140727
dc.identifier.uri https://hdl.handle.net/11147/12772
dc.language.iso en en_US
dc.publisher Taylor & Francis en_US
dc.relation.ispartof Tribology Transactions en_US
dc.rights info:eu-repo/semantics/embargoedAccess en_US
dc.subject CFR-PEEK en_US
dc.subject Finite-element modeling en_US
dc.subject Polyethylene wear en_US
dc.subject Residual stress en_US
dc.subject Total hip replacement en_US
dc.subject Wear fraction en_US
dc.title The Computational Approach To Predicting Wear: Comparison of Wear Performance of Cfr-Peek and Xlpe Liners in Total Hip Replacement en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id 0000-0001-5077-8927
gdc.author.id 0000-0001-5077-8927 en_US
gdc.author.institutional Alpkaya, Alican Tuncay
gdc.author.institutional Mihçin, Şenay
gdc.bip.impulseclass C4
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access embargoed access
gdc.coar.type text::journal::journal article
gdc.collaboration.industrial false
gdc.description.department İzmir Institute of Technology. Mechanical Engineering en_US
gdc.description.endpage 72
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 59
gdc.description.volume 66
gdc.description.wosquality Q2
gdc.identifier.openalex W4307644638
gdc.identifier.wos WOS:000899732300001
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.diamondjournal false
gdc.oaire.impulse 6.0
gdc.oaire.influence 2.867205E-9
gdc.oaire.isgreen true
gdc.oaire.popularity 5.9542096E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 03 medical and health sciences
gdc.oaire.sciencefields 0302 clinical medicine
gdc.oaire.sciencefields 0206 medical engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.collaboration National
gdc.openalex.fwci 3.32602131
gdc.openalex.normalizedpercentile 0.89
gdc.openalex.toppercent TOP 10%
gdc.opencitations.count 5
gdc.plumx.facebookshareslikecount 31
gdc.plumx.mendeley 11
gdc.plumx.scopuscites 10
gdc.scopus.citedcount 10
gdc.wos.citedcount 7
relation.isAuthorOfPublication.latestForDiscovery 81477b5b-73ae-48f4-a1bc-7fd35825bdac
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4003-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
The Computational Approach to Predicting Wear Comparison of Wear Performance of CFR PEEK and XLPE Liners in Total Hip Replacement.pdf
Size:
3.49 MB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Name:
license.txt
Size:
3.2 KB
Format:
Item-specific license agreed upon to submission
Description: