Disinfection of Liqued Egg Products by Using Uv Light

Loading...

Date

Journal Title

Journal ISSN

Volume Title

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

The application of UV treatment to continuous flow of liquid egg products is the initial study among the others. The objective of this study was to investigate the efficiency of UV-C radiation as a non-thermal pasteurization process for liquid egg products (LEPs). The outcomes of this study were evaluated from the rheological, biodosimetric and inactivation efficiency points of view. The results pertaining to rheological characterization, physical and optical measurements of the fresh and pasteurized LEPs indicated that liquid whole egg (LWE) and liquid egg white (LEW) showed Newtonian behavior within the range studied. Liquid egg yolk (LEY) exhibited pseudoplastic and time independent behavior in temperature ranges from 4 C to 25 C. But its rheological behavior was affected at pasteurization temperature and showed thixotropy and time dependent. The biodosimetric study based on the UV treatment of LEPs by using collimated beam apparatus pointed out that the best reduction was achieved in liquid egg white (LEW) when the fluid depth and UV dose were 0.153 cm and 98 mJ/cm2, respectively. Maximum inactivation was 0.675-log CFU/ml in liquid egg yolk (LEY) and 0.316-log CFU/ml in liquid whole egg (LWE). The kinetics of UV inactivation of E.coli in LEPs was found nonlinear. Our results emphasize that UV-C radiation can be used as a pre-treatment process or combined with mild heat treatment to reduce the adverse effects of thermal pasteurization of LEPs. The efficacies of short wave ultraviolet light (UV-C) as a non-thermal process for LEW were investigated in the continuous flow UV reactor based on the result derived from the biodosimetric study. Maximum 0.2 log reduction was achieved after 5 cycle of operation. The efficiency of the UV light treatment in continuous flow UV reactor was found to be lower compared to bench-top studies. This is attributed to the problems caused by inefficient design of UV chamber. Results of these work showed that the UV reactor was designed poorly to supply enough UV irradiation exposure for all the fluid elements in the system. Redesigning of the system was suggested.

Description

Thesis (Master)--Izmir Institute of Technology, Biotechnology, Izmir, 2007
Includes bibliographical references (leaves: 80-86)
Text in English; Abstract: Turkish and English
xv, 104 leaves

Keywords

Fields of Science

Citation

WoS Q

Scopus Q

Source

Volume

Issue

Start Page

End Page

Page Views

793

checked on Apr 29, 2026

Downloads

487

checked on Apr 29, 2026

Google Scholar Logo
Google Scholar™

Sustainable Development Goals

ZERO HUNGER2
ZERO HUNGER
CLEAN WATER AND SANITATION6
CLEAN WATER AND SANITATION
AFFORDABLE AND CLEAN ENERGY7
AFFORDABLE AND CLEAN ENERGY
INDUSTRY, INNOVATION AND INFRASTRUCTURE9
INDUSTRY, INNOVATION AND INFRASTRUCTURE
RESPONSIBLE CONSUMPTION AND PRODUCTION12
RESPONSIBLE CONSUMPTION AND PRODUCTION
CLIMATE ACTION13
CLIMATE ACTION
LIFE BELOW WATER14
LIFE BELOW WATER