How Does Arsenic Speciation (arsenite and Arsenate) in Groundwater Affect the Performance of an Aerated Electrocoagulation Reactor and Human Health Risk?

Loading...

Date

2022

Authors

Gören, Ayşegül Yağmur

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Arsenic (As) occurrence in water resources has become one of the most critical environmental problems worldwide. The detrimental health impacts on humans have been reported due to the consumption of As-contaminated groundwater resources. Consumption of As-containing water over the long term can cause arsenicosis and chronic effects on human health due to its toxicity. Several treatment processes are available for As removals such as coagulation, ion exchange, adsorption, and membrane technologies but they have various major drawbacks. In the present work, therefore, an aerated electrocoagulation (EC) system with aluminum anodes was operated for simultaneous arsenate (As(V)) and arsenite (As(III)) removal to overcome the disadvantages of other processes such as, sludge formation, difficulties in operation, high operating costs, high energy consumption, and the requirement of pre-treatment process and to enhance the conventional EC process. The combined effects of the applied current (0.075–0.3 A), aeration rate (0–6 L/min), pH (6.5–8.5), and As speciation (As(V)-As(III)) were studied on As removal efficiency. The findings revealed that As removal mostly depended on the airflow rate and the applied current in the EC system. The highest As removal efficiency (99.1%) was obtained at an airflow rate of 6 L/min, a pH of 6.5, an initial As (V) concentration of 200 μg/L, and a current of 0.3 A, with an energy consumption of 2.85 kWh/m3 and an operating cost of 0.66 $/m3. The human health risk assessment of treated water was also examined to understand the performance of the EC system. At most of the experimental runs, the chronic toxic risk (CTR) and carcinogenic risk (CR) of As were within the permissible limits except for an airflow rate of 0–2 L/min, an initial pH of 8.5, and a current of 0.075–0.15 A for high initial As (III) concentrations. Overall, the As removal performance and groundwater risk assessment show that the EC process is a promising option for industrial applications.

Description

The authors would like to give thanks for the financial support from TUBITAK (The Scientific and Technical Research Council of Turkey, Project Number = 111Y103)

Keywords

Electrocoagulation, Arsenic, Groundwater, Al balls, Arsenites, Arsenic, Water Purification, Electrocoagulation, Arsenates, Humans, Adsorption, Groundwater, Water Pollutants, Chemical

Fields of Science

05 social sciences, 0211 other engineering and technologies, 02 engineering and technology, 0502 economics and business

Citation

WoS Q

Q1

Scopus Q

N/A
OpenCitations Logo
OpenCitations Citation Count
7

Source

Science of the Total Environment

Volume

808

Issue

Start Page

End Page

PlumX Metrics
Citations

CrossRef : 8

Scopus : 9

Captures

Mendeley Readers : 23

SCOPUS™ Citations

9

checked on Apr 27, 2026

Web of Science™ Citations

9

checked on Apr 27, 2026

Page Views

3338

checked on Apr 27, 2026

Downloads

11

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.07023814

Sustainable Development Goals