Modeling of Hemodialysis Operation

dc.contributor.advisor Alsoy Altınkaya, Sacide
dc.contributor.author Abacı, Hasan Erbil
dc.date.accessioned 2014-07-22T13:52:43Z
dc.date.available 2014-07-22T13:52:43Z
dc.date.issued 2008
dc.description Thesis (Master)--Izmir Institute of Technology, Chemical Engineering, Izmir, 2008 en_US
dc.description Includes bibliographical references (leaves: 82-91) en_US
dc.description Text in English; Abstract: Turkish and English en_US
dc.description xiii, 91 leaves en_US
dc.description.abstract Recent studies have shown that the effectiveness of hemodialysis is based on module geometry, membrane properties and operating conditions. Various experimental work exist in the literature concentrated on the synthesis of new hemodialysis membranes. However, optimization of membrane structure requires extensive and time consuming experimentations. Therefore, mathematical models are neccessary that can be used to predict the performance of hemodialysis operation. In this study, a predictive theoretical model was developed to predict the solute concentrations in patient.s blood and optimize the efficiency of hemodialysis operation. The model takes into account simultaneous mass and momentum transfer along with the adsorption of rejected protein molecules on the surface of the membrane.Model predictions show that blood and dialysate flowrates are effective for all sizes of molecules. The change in structural properties of the membrane makes no effect on the total removal of urea beacause of its high clearance. On the other hand, a considerable increment in the clearance of larger molecular weight solutes occurs as the pore size and porosity of the membrane increases. The most important design parameter for dialysis unit which influence the solute clearances significantly is found to be the effective diameter among the fibers in the dialyzer.The model is extended to investigate the use of urease immobilized membranes on the efficiency of the hemodialysis operation. The results have shown that urease immobilization enhances the removal of urea from the blood and decreases the protein adsorption capacity of the polysulfone membrane.Model predictions are compared with different sets of clearance data available in the literature. The agreement is found to be satisfactory which suggests that the model can be used as a tool to design or test the performance of dialysis units. en_US
dc.identifier.uri https://hdl.handle.net/11147/3926
dc.language.iso en en_US
dc.publisher Izmir Institute of Technology en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject.lcc RC901.7.E53 A116 2008 en
dc.subject.lcsh Hemodialysis en
dc.subject.lcsh Hemodialysis--Mathematical models en
dc.subject.lcsh Blood--Filtration en
dc.title Modeling of Hemodialysis Operation en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
gdc.author.institutional Abacı, Hasan Erbil
gdc.coar.access open access
gdc.coar.type text::thesis::master thesis
gdc.description.department Thesis (Master)--İzmir Institute of Technology, Chemical Engineering en_US
gdc.description.publicationcategory Tez en_US
gdc.description.scopusquality N/A
gdc.description.wosquality N/A
relation.isAuthorOfPublication.latestForDiscovery 78565daf-6b4c-45ad-9cc0-2b2630ea3aa1
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4021-8abe-a4dfe192da5e

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Name:
T000713.pdf
Size:
894.16 KB
Format:
Adobe Portable Document Format
Description:
MasterThesis

License bundle

Now showing 1 - 1 of 1
Loading...
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: