Simultaneous Validation of Wearable Motion Capture System for Lower Body Applications: Over Single Plane Range of Motion (rom) and Gait Activities

Loading...

Date

2022

Authors

Mihçin, Şenay

Journal Title

Journal ISSN

Volume Title

Publisher

Walter de Gruyter GmbH

Open Access Color

Green Open Access

Yes

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Top 10%
Popularity
Top 10%

relationships.isProjectOf

relationships.isJournalIssueOf

Abstract

Extracting data from {Zhu, 2019 #5} daily life activities is important in biomechanical applications to define exact boundary conditions for the intended use-based applications. Although optoelectronic camera-marker based systems are used as gold standard tools for medical applications, due to line-of-sight problem, there is a need for wearable, affordable motion capture (MOCAP) systems. We investigate the potential use of a wearable inertial measurement unit (IMU) based-wearable MOCAP system for biomechanical applications. The in vitro proof of concept is provided for the full lower body consisting of hip, knee, and ankle joints via controlled single-plane anatomical range of motion (ROM) simulations using an electrical motor, while collecting data simultaneously via opto-electronic markers and IMU sensors. On 15 healthy volunteers the flexion-extension, abduction-Adduction, internal-external rotation (ROM) values of hip and, the flexion-extension ROM values of the knee and ankle joints are calculated for both systems. The Bland-Altman graphs showed promising agreement both for in vitro and in vivo experiments. The maximum Root Mean Square Errors (RMSE) between the systems in vitro was 3.4° for hip and 5.9° for knee flexion motion in vivo, respectively. The gait data of the volunteers were assessed between the heel strike and toe off events to investigate the limits of agreement, calculating the population averages and standard deviation for both systems over the gait cycle. The maximum difference was for the ankle joint <6°. The results show that proposed system could be an option as an affordable-democratic solution.

Description

Keywords

Range of motion, Gait analysis, Motion capture (MOCAP) systems, Proof of concept, Wearable Electronic Devices, Knee Joint, Humans, Range of Motion, Articular, Gait, Biomechanical Phenomena

Fields of Science

03 medical and health sciences, 0302 clinical medicine

Citation

WoS Q

Q3

Scopus Q

Q3
OpenCitations Logo
OpenCitations Citation Count
14

Source

Biomedizinische Technik

Volume

67

Issue

3

Start Page

185

End Page

199
PlumX Metrics
Citations

CrossRef : 3

Scopus : 23

PubMed : 7

Captures

Mendeley Readers : 30

SCOPUS™ Citations

22

checked on Apr 27, 2026

Web of Science™ Citations

22

checked on Apr 27, 2026

Page Views

3067

checked on Apr 27, 2026

Downloads

4

checked on Apr 27, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
4.42316354

Sustainable Development Goals