Determination of Aluminum Rolling Oil and Machinery Oil Residues on Finished Aluminum Sheet and Foil Using Elemental Analysis and Fourier Transform Infrared Spectroscopy Coupled With Multivariate Calibration

dc.contributor.author Uçar,Ö.I.
dc.contributor.author Altuner,H.M.
dc.contributor.author Günyüz,M.
dc.contributor.author Dündar,M.M.
dc.contributor.author Özdemir,D.
dc.date.accessioned 2024-09-24T15:50:10Z
dc.date.available 2024-09-24T15:50:10Z
dc.date.issued 2014
dc.description.abstract The surface characteristics of rolled aluminum products such as sheets and foils are strongly affected by the particular rolling process and the type of aluminum rolling oil compositions. After the rolling process, coiled aluminum sheets and foils undergoes annealing to form desired crystal structure and remove the rolling oil residues. Depending on the time and the temperature that rolled aluminum exposed for annealing, rolling oil residues are mostly removed from the coiled aluminum products but if there is any contamination in rolling oil due to hydraulic and gearing parts of the rolling systems these heavier oils are not easily evaporates from the aluminum surfaces especially inner parts of the coiled aluminum sheets and foils. These rolling oil contaminants create serious problems for the some specific applications of these aluminum products in certain industries such as automotive and coating as remaining thin oil layer prevents proper painting and coating. Therefore, it is very crucial for the rolling industry to be able to monitor the heavy oil contamination on the rolled products and determine the source of these contaminants .In this study, it was aimed to develop a nondestructive infrared spectroscopic method combined with chemometric multivariate calibration techniques for the quantitative determination of rolling oil residues and contaminants on the rolled aluminum products. To be able to generate multivariate calibration methods, an industrial elemental analysis system was adopted for the quantitative determination of heavy oil contaminants on the rolled aluminum products and these were used as reference values for infrared analysis of the same samples. In addition, apart from conventional use of elemental analysis systems for the total organic analysis, the raw data (raw chromatogram) obtained from elemental analysis was used to directly generate multivariate calibration models for each contaminant by using synthetically contaminated surfaces as the calibration samples. The results promised that elemental analysis can be used not just for the total organic content but also specifically to determine amount of each infrared spectroscopy with grazing angle spectra collection accessories can be used for nondestructive analysis of these contaminants. © 2014 The Minerals, Metals & Materials Society. en_US
dc.identifier.doi 10.1002/9781118888438.ch71
dc.identifier.isbn 978-111888843-8
dc.identifier.isbn 978-111888908-4
dc.identifier.scopus 2-s2.0-84927976403
dc.identifier.uri https://doi.org/10.1002/9781118888438.ch71
dc.identifier.uri https://hdl.handle.net/11147/14729
dc.language.iso en en_US
dc.publisher Wiley Blackwell en_US
dc.relation.ispartof Light Metals 2014 en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Aluminum rolling en_US
dc.subject Elemental analysis en_US
dc.subject FTIR en_US
dc.subject Genetic algorithms en_US
dc.subject Multivariate calibration en_US
dc.subject Rolling oil additives and contaminants en_US
dc.title Determination of Aluminum Rolling Oil and Machinery Oil Residues on Finished Aluminum Sheet and Foil Using Elemental Analysis and Fourier Transform Infrared Spectroscopy Coupled With Multivariate Calibration en_US
dc.type Book Part en_US
dspace.entity.type Publication
gdc.author.scopusid 36136149200
gdc.author.scopusid 37023083100
gdc.author.scopusid 18634403300
gdc.author.scopusid 59270099600
gdc.author.scopusid 57212093641
gdc.coar.access open access
gdc.coar.type text::book::book part
gdc.collaboration.industrial false
gdc.description.department Izmir Institute of Technology en_US
gdc.description.departmenttemp Uçar Ö.I., Assan Alüminyum San. ve Tic AS, Tuzla, Istanbul, 34940, Turkey; Altuner H.M., Assan Alüminyum San. ve Tic AS, Tuzla, Istanbul, 34940, Turkey; Günyüz M., Assan Alüminyum San. ve Tic AS, Tuzla, Istanbul, 34940, Turkey; Dündar M.M., Assan Alüminyum San. ve Tic AS, Tuzla, Istanbul, 34940, Turkey; Özdemir D., Izmir Institute of Technology, Urla, Izmir, 35430, Turkey en_US
gdc.description.endpage 420 en_US
gdc.description.publicationcategory Kitap Bölümü - Uluslararası en_US
gdc.description.scopusquality N/A
gdc.description.startpage 415 en_US
gdc.description.volume 9781118889084 en_US
gdc.description.wosquality N/A
gdc.identifier.openalex W4237118685
gdc.index.type Scopus
gdc.openalex.fwci 0.0
gdc.openalex.normalizedpercentile 0.0
gdc.opencitations.count 0
gdc.plumx.mendeley 7
gdc.plumx.scopuscites 0
gdc.scopus.citedcount 0
relation.isAuthorOfPublication.latestForDiscovery 451421f9-0bfe-4cc9-9c73-6252ce7a8a27
relation.isOrgUnitOfPublication.latestForDiscovery 9af2b05f-28ac-4003-8abe-a4dfe192da5e

Files