Mechanical Engineering / Makina Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/4129
Browse
5 results
Search Results
Article Citation - WoS: 9Citation - Scopus: 11Experimental Investigation of Spray Characteristics of Ethyl Esters in a Constant Volume Chamber(Springer, 2024) Ulu, A.; Yildiz, G.; Özkol, Ü.; Rodriguez, A.D.Abstract: Biodiesels are mainly produced via the utilization of methanol in transesterification, which is the widespread biodiesel production process. The majority of this methanol is currently obtained from fossil resources, i.e. coal and natural gas. However, in contrast with methanol, biomass-based ethanol can also be used to produce biodiesels; this could allow the production line to become fully renewable. This study aimed to investigate the spray characteristics of various ethyl ester type biodiesels derived from sunflower and corn oils in comparison to methyl esters based on the same feedstocks and reference petroleum-based diesel. Spray penetration length (SPL) and spray cone angle (SCA) were experimentally evaluated in a constant volume chamber allowing optical access, under chamber pressures of 0, 5, 10 and 15 bar and injection pressures of 600 and 800 bar. Sauter mean diameter (SMD) values were estimated by using an analytical correlation. Consequently, ethyl esters performed longer SPL (2.8–20%) and narrower SCA (5.1–19%) than diesel under ambient pressures of 5 and 10 bar. Although the SMD values of ethyl esters were 48% higher than diesel on average, their macroscopic spray characteristics were very similar to those of diesel under 15 bar chamber pressure. Moreover, ethyl esters were found to be very similar to methyl esters in terms of spray characteristics. The differences in SPL, SCA and SMD values for both types of biodiesels were lower than 4%. When considering the uncertainty (± 0.84%) and repeatability (±5%) ratios, the difference between the spray characteristics of methyl and ethyl esters was not major. Graphical abstract: [Figure not available: see fulltext.] © 2022, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.Article Citation - WoS: 8Citation - Scopus: 9Dynamic Computational Wear Model of Peek-On Bearing Couple in Total Hip Replacements(Elsevier, 2023) Alpkaya, Alican Tuncay; Mihçin, ŞenayUnderstanding wear mechanisms is a key factor to prevent primary failures causing revision surgery in total hip replacement (THR) applications. This study introduces a wear prediction model of (Polyetheretherketone) PEEK-on-XLPE (cross-linked polyethylene) bearing couple utilized to investigate the wear mechanism under 3D-gait cycle loading over 5 million cycles (Mc). A 32-mm PEEK femoral head and 4-mm thick XLPE bearing liner with a 3-mm PEEK shell are modeled in a 3D explicit finite element modeling (FEM) program. The volumetric and linear wear rates of XLPE liner per every million cycles were predicted as 1.965 mm3/Mc, and 0.0032 mm/Mc respectively. These results are consistent with the literature. PEEK-on-XLPE bearing couple exhibits a promising wear performance used in THR application. The wear pattern evolution of the model is similar to that of conventional polyethylene liners. Therefore, PEEK could be proposed as an alternative material to the CoCr head, especially used in XLPE-bearing couples. The wear prediction model could be utilized to improve the design parameters with the aim of prolonging the life span of hip implants. © 2023Article Citation - WoS: 3Citation - Scopus: 3Quasi-Static and Dynamic Brazilian Testing and Failure Analysis of a Deer Antler in the Transverse To the Osteon Growth Direction(Elsevier, 2023) Orhan, Mehmet; Sarıkaya, Mustafa Kemal; Taşdemirci, Alper; Tuncer, Can; Güden, MustafaThe transverse tensile strength of a naturally fallen red deer antler (Cervus Elaphus) was determined through indirect Brazilian tests using dry disc-shape specimens at quasi-static and high strain rates. Dynamic Brazilian tests were performed in a compression Split-Hopkinson Pressure Bar. Quasi-static tensile and indirect Brazilian tests were also performed along the osteon growth direction for comparison. The quasi-static transverse tensile strength ranged 31.5–44.5 MPa. The strength increased to 83 MPa on the average in the dynamic Brazilian tests, proving a rate sensitive transverse strength. The quasi-static tensile strength in the osteon growth direction was however found comparably higher, 192 MPa. A Weibull analysis indicated a higher tensile ductility in the osteon growth direction than in the transverse to the osteon growth direction. The microscopic analysis of the quasi-static Brazilian test specimens (tensile strain along the osteon growth direction) revealed a micro-cracking mechanism operating by the crack deflection/twisting at the lacunae in the concentric lamellae region and at the interface between concentric lamellae and interstitial lamellae. On the other side, the specimens in the transverse direction fractured in a more brittle manner by the separation/delamination of the concentric lamellae and pulling of the interstitial lamellae. The detected increase in the transverse strength in the high strain rate tests was further ascribed to the pull and fracture of the visco-plastic collagen fibers in the interstitial lamellae. This was also confirmed microscopically; the dynamically tested specimens exhibited flatter fracture surfaces. © 2023 Elsevier LtdArticle Citation - WoS: 21Citation - Scopus: 23Wearable Motion Capture System Evaluation for Biomechanical Studies for Hip Joints(ASME, 2021) Mihçin, Şenay; Çıklaçandır, Samet; Koçak, Mertcan; Tosun, AliyeHuman motion capture (MOCAP) systems are vital while determining the loads occurring at the joints. Most of the clinical MOCAP systems are very costly, requiring investment and infrastructure. Therefore, alternative technologies are in demand. In this study, a novel markerless wearable MOCAP system was assessed for its compatibility with a biomechanical modeling software. To collect evidence, experiments were designed in two stages for quantifying the range of motion (ROM) of the hip joint, in vitro and in vivo. Three constrained single-plane motions-abduction/adduction, flexion/extension, and internal/external rotation movements of the active leg-were analyzed. The data were collected from 14 healthy volunteers, using the wearable system and a medical grade optoelectronic MOCAP system simultaneously and compared against. For the in vitro study, the root-mean-square error (RMSE) for the abduction/adduction motion of the hip joint was calculated as 0.11deg/0.30deg and 0.11deg/0.09deg, respectively, for the wearable and the opto-electronic system. The in vivo Bland-Altman plots showed that the two system data are comparable. The simulation software is found compatible to run the simulations in offline mode. The wearable system could be utilized in the field of biomechanics software for running the kinetic simulations. The results demonstrated that the wearable system could be an alternative in the field of biomechanics based on the evidence collected.Article Citation - WoS: 26Citation - Scopus: 27Electric Charge of Nanopatterned Silica Surfaces(Royal Society of Chemistry, 2019) Özçelik, H. Gökberk; Barışık, MuratThe most recent technologies employ nanoscale surface patterning or roughening in order to engineer desired properties on a surface. Electrokinetic properties at the interface of such surfaces and ionic liquids show different behavior to the well-known theoretical descriptions. Basically, the ionic distribution on the surface differs due to electrical double layer overlap effects in the pits and curvature effects at the tips of surface structures. Generally, the charge density of a surface is assumed to be a material property and surface roughness effects are overlooked in most of the literature. In contrast, we properly calculated the local surface charges based on surface chemistry at the corresponding local ionic concentration (charge regulation) for various surface roughness and solution conditions. The results showed that the surface charge density of silica decreased at the pits but increased at the tips of surface patterns. Even for the simplest case of self-repeating surface structures, the average of local surface charges becomes lower than the theoretical predictions. Based on numerical calculations, a phenomenological model was developed as an extension to the existing flat surface theory, which can successfully predict the average surface charge on a nano patterned surface as a function of the surface pattern size, ionic concentration and pH.