Mechanical Engineering / Makina Mühendisliği

Permanent URI for this collectionhttps://hdl.handle.net/11147/4129

Browse

Search Results

Now showing 1 - 2 of 2
  • Article
    Citation - WoS: 22
    Citation - Scopus: 22
    Simultaneous Validation of Wearable Motion Capture System for Lower Body Applications: Over Single Plane Range of Motion (rom) and Gait Activities
    (Walter de Gruyter GmbH, 2022) Mihçin, Şenay
    Extracting data from {Zhu, 2019 #5} daily life activities is important in biomechanical applications to define exact boundary conditions for the intended use-based applications. Although optoelectronic camera-marker based systems are used as gold standard tools for medical applications, due to line-of-sight problem, there is a need for wearable, affordable motion capture (MOCAP) systems. We investigate the potential use of a wearable inertial measurement unit (IMU) based-wearable MOCAP system for biomechanical applications. The in vitro proof of concept is provided for the full lower body consisting of hip, knee, and ankle joints via controlled single-plane anatomical range of motion (ROM) simulations using an electrical motor, while collecting data simultaneously via opto-electronic markers and IMU sensors. On 15 healthy volunteers the flexion-extension, abduction-Adduction, internal-external rotation (ROM) values of hip and, the flexion-extension ROM values of the knee and ankle joints are calculated for both systems. The Bland-Altman graphs showed promising agreement both for in vitro and in vivo experiments. The maximum Root Mean Square Errors (RMSE) between the systems in vitro was 3.4° for hip and 5.9° for knee flexion motion in vivo, respectively. The gait data of the volunteers were assessed between the heel strike and toe off events to investigate the limits of agreement, calculating the population averages and standard deviation for both systems over the gait cycle. The maximum difference was for the ankle joint <6°. The results show that proposed system could be an option as an affordable-democratic solution.
  • Article
    Citation - WoS: 4
    Citation - Scopus: 5
    Effects of Tib2 Nanoparticle Content on the Microstructure and Mechanical Properties of Aluminum Matrix Nanocomposites
    (Walter de Gruyter GmbH, 2017) Kandemir, Sinan
    The present work reports the fabrication of A357 alloy matrix nanocomposites reinforced with 0.5, 1.0 and 2.0 wt.-% TiB2 nanoparticles (20-30 nm) by a novel method which is the combination of semi-solid mechanical mixing and ultrasonic dispersion of nanoparticles in liquid state. The microstructural and mechanical properties of the fabricated nanocomposites were investigated. The microstructural studies conducted with optical and advanced electron microscopes indicated that reasonably effective deagglomeration and uniform distribution of TiB2 nanoparticles into the matrix were achieved. Transmission electron microscopy studies also confirmed that the nanoparticles were embedded into the matrix and a good bonding was obtained between the matrix and the reinforcement. Increasing nanoparticle content led to grain refinement and significant enhancement in the mechanical properties of nanocomposites. The addition of 0.5, 1.0, and 2.0 wt.-% TiB2 nanoparticles increased the 0.2 % proof stress of matrix alloy by approximately 31, 48 and 61 %, respectively. The contribution of different mechanisms to the strength enhancement is discussed. It is proposed that the strengthening is mainly due to Orowan mechanism and dislocation generation effect by the coefficient of thermal expansion mismatch between the TiB2 nanoparticles and the matrix.