Mechanical Engineering / Makina Mühendisliği
Permanent URI for this collectionhttps://hdl.handle.net/11147/4129
Browse
31 results
Filters
Settings
Search Results
Article Citation - WoS: 9Citation - Scopus: 11Experimental Investigation of Spray Characteristics of Ethyl Esters in a Constant Volume Chamber(Springer, 2024) Ulu, A.; Yildiz, G.; Özkol, Ü.; Rodriguez, A.D.Abstract: Biodiesels are mainly produced via the utilization of methanol in transesterification, which is the widespread biodiesel production process. The majority of this methanol is currently obtained from fossil resources, i.e. coal and natural gas. However, in contrast with methanol, biomass-based ethanol can also be used to produce biodiesels; this could allow the production line to become fully renewable. This study aimed to investigate the spray characteristics of various ethyl ester type biodiesels derived from sunflower and corn oils in comparison to methyl esters based on the same feedstocks and reference petroleum-based diesel. Spray penetration length (SPL) and spray cone angle (SCA) were experimentally evaluated in a constant volume chamber allowing optical access, under chamber pressures of 0, 5, 10 and 15 bar and injection pressures of 600 and 800 bar. Sauter mean diameter (SMD) values were estimated by using an analytical correlation. Consequently, ethyl esters performed longer SPL (2.8–20%) and narrower SCA (5.1–19%) than diesel under ambient pressures of 5 and 10 bar. Although the SMD values of ethyl esters were 48% higher than diesel on average, their macroscopic spray characteristics were very similar to those of diesel under 15 bar chamber pressure. Moreover, ethyl esters were found to be very similar to methyl esters in terms of spray characteristics. The differences in SPL, SCA and SMD values for both types of biodiesels were lower than 4%. When considering the uncertainty (± 0.84%) and repeatability (±5%) ratios, the difference between the spray characteristics of methyl and ethyl esters was not major. Graphical abstract: [Figure not available: see fulltext.] © 2022, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.Article Citation - WoS: 7Citation - Scopus: 7Investigating the Effects of Pa66 Electrospun Nanofibers Layered Within an Adhesive Composite Joint Fabricated Under Autoclave Curing(American Chemical Society, 2023) Esenoğlu, Gözde; Tanoğlu, Metin; Barışık, Murat; İplikçi, Hande; Yeke, Melisa; Nuhoğlu, Kaan; Türkdoğan, Ceren; Martin, Seçkin; Aktaş, Engin; Dehneliler, Serkan; Gürbüz, Ahmet Ayberk; İriş, Mehmet ErdemEnhancing the performance of adhesively joined composite components is crucial for various industrial applications. In this study, polyamide 66 (PA66) nanofibers produced by electrospinning were coated on unidirectional carbon/epoxy prepregs to increase the bond strength of the composites. Carbon/epoxy prepregs with/without PA66 nanofiber coating on the bonding region were fabricated using the autoclave, which is often used in the aerospace industry. The single lap shear Charpy impact energy and Mode-I fracture toughness tests were employed to examine the effects of PA66 nanofibers on the mechanical properties of the joint region. Scanning electron microscopy (SEM) was used to investigate the nanofiber morphology and fracture modes. The thermal characteristics of Polyamide 66 nanofibers were explored by using differential scanning calorimetry (DSC). We observed that the electrospun PA66 nanofiber coating on the prepreg surfaces substantially improves the joint strength. Results revealed that the single lap shear and Charpy impact strength values of the composite joint are increased by about 79 and 24%, respectively, by coating PA66 nanofibers onto the joining region. The results also showed that by coating PA66 nanofibers, the Mode-I fracture toughness value was improved by about 107% while the glass transition temperature remained constant.Data Paper Citation - WoS: 15Citation - Scopus: 20Database Covering the Prayer Movements Which Were Not Available Previously(Nature Publishing Group, 2023) Mihçin, Şenay; Şahin, Ahmet Mert; Yılmaz, Mehmet; Alpkaya, Alican Tuncay; Tuna, Merve; Akdeniz, Sevinç; Can, Nuray Korkmaz; Tosun, Aliye; Şahin, SerapLower body implants are designed according to the boundary conditions of gait data and tested against. However, due to diversity in cultural backgrounds, religious rituals might cause different ranges of motion and different loading patterns. Especially in the Eastern part of the world, diverse Activities of Daily Living (ADL) consist of salat, yoga rituals, and different style sitting postures. A database covering these diverse activities of the Eastern world is non-existent. This study focuses on data collection protocol and the creation of an online database of previously excluded ADL activities, targeting 200 healthy subjects via Qualisys and IMU motion capture systems, and force plates, from West and Middle East Asian populations with a special focus on the lower body joints. The current version of the database covers 50 volunteers for 13 different activities. The tasks are defined and listed in a table to create a database to search based on age, gender, BMI, type of activity, and motion capture system. The collected data is to be used for designing implants to allow these sorts of activities to be performed.Article Citation - WoS: 3Citation - Scopus: 3Quasi-Static and Dynamic Brazilian Testing and Failure Analysis of a Deer Antler in the Transverse To the Osteon Growth Direction(Elsevier, 2023) Orhan, Mehmet; Sarıkaya, Mustafa Kemal; Taşdemirci, Alper; Tuncer, Can; Güden, MustafaThe transverse tensile strength of a naturally fallen red deer antler (Cervus Elaphus) was determined through indirect Brazilian tests using dry disc-shape specimens at quasi-static and high strain rates. Dynamic Brazilian tests were performed in a compression Split-Hopkinson Pressure Bar. Quasi-static tensile and indirect Brazilian tests were also performed along the osteon growth direction for comparison. The quasi-static transverse tensile strength ranged 31.5–44.5 MPa. The strength increased to 83 MPa on the average in the dynamic Brazilian tests, proving a rate sensitive transverse strength. The quasi-static tensile strength in the osteon growth direction was however found comparably higher, 192 MPa. A Weibull analysis indicated a higher tensile ductility in the osteon growth direction than in the transverse to the osteon growth direction. The microscopic analysis of the quasi-static Brazilian test specimens (tensile strain along the osteon growth direction) revealed a micro-cracking mechanism operating by the crack deflection/twisting at the lacunae in the concentric lamellae region and at the interface between concentric lamellae and interstitial lamellae. On the other side, the specimens in the transverse direction fractured in a more brittle manner by the separation/delamination of the concentric lamellae and pulling of the interstitial lamellae. The detected increase in the transverse strength in the high strain rate tests was further ascribed to the pull and fracture of the visco-plastic collagen fibers in the interstitial lamellae. This was also confirmed microscopically; the dynamically tested specimens exhibited flatter fracture surfaces. © 2023 Elsevier LtdArticle Citation - WoS: 13Citation - Scopus: 18Finite Element Study of Peek Materials Applied in Post-Retained Restorations(MDPI, 2022) Yu, Hao; Feng, Zhihong; Wang, Ling; Mihçin, Şenay; Kang, Jianfeng; Bai, Shizhu; Zhao, YiminBackground: This study aimed to investigate the biomechanical behaviors of polyether ether ketone (PEEK) and traditional materials (titanium and fiber) when used to restore tooth defects in the form of prefabricated post or customized post via computational modelling. Methods: First, the prototype of natural tooth, and the prototypes of prefabricated post and customized post were established, respectively, whilst the residual root was restored with dentin ferrule using reverse engineering methods. Then, the stress and strain of CFR-PEEK (PEEK reinforced by 30% carbon fiber) and pure PEEK (PEEK without any reprocessing) post were compared with those made in traditional materials using the three-dimensional finite element method. Results: From the stress point of view, compared with metal and fiber posts, CFR-PEEK and pure PEEK prefabricated post both demonstrated reduced post-core interface stress, post stress, post-root cement stress and root cement stress; moreover, CFR-PEEK and pure PEEK customized post demonstrated reduced post stress, post-root cement stress and root cement stress, while the strain of CFR-PEEK post was the closest to that of dentin. Conclusions: Compared with the traditional posts, both the CFR-PEEK and pure PEEK posts could reduce the risk of debonding and vertical root fracture, whether they were used as prefabricated posts or customized posts, but the biomechanical behavior of carbon fiber-reinforced CFR-PEEK restorations was the closest to dentin, no matter if they were used as prefabricated post or customized post. Therefore, the CFR-PEEK post could be more suitable to restore massive tooth defects. Pure PEEK needs filler reinforcement to be used for post-retained restoration.Article Citation - WoS: 8Citation - Scopus: 10Spray Analysis of Biodiesels Derived From Various Biomass Resources in a Constant Volume Spray Chamber(American Chemical Society, 2022) Ulu, Anılcan; Yıldız, Güray; Rodriguez, Alvaro Diez; Özkol, ÜnverThis research aimed to analyze the spray characteristics of various biodiesels, which have rarely been investigated in terms of spray analysis in the literature compared to fossil diesel. For this purpose, four different methyl ester-type biodiesels were produced from canola, corn, cottonseed, and sunflower oils. These feedstocks were selected due to their wide availability in Turkey and being among the significant resources for biodiesel production. Measured physical properties of biodiesel samples showed that biodiesel fuels had, on average, 1.7 to 1.9 times higher viscosities, 5.3 to 6.6% larger densities, and 37 to 39.1% higher contact angle values than the reference diesel fuel. Spray characteristics of all fuels were experimentally examined in a constant volume spray chamber under chamber pressures of 0, 5, 10, and 15 bar and injection pressures of 600, 800, and 1000 bar. All tested biodiesels performed, on average, 3 to 20% longer spray penetration lengths, 5 to 30% narrower spray cone angles, and 5-18% lesser spray areas than the reference diesel fuel under chamber pressures of 5 and 10 bar. No significant differences occurred at 15 bar ambient pressure between biodiesels and diesel. In addition, analytical and empirical predictions showed that biodiesels had around 21.2-35.1% larger SMD values and approximately 7% lower air entrainment.Article Citation - WoS: 9Citation - Scopus: 11Experimental Investigation of Spray Characteristics of Ethyl Esters in a Constant Volume Chamber(Springer, 2022) Ulu, Anılcan; Yıldız, Güray; Özkol, Ünver; Rodriguez, Alvaro DiezAbstract: Biodiesels are mainly produced via the utilization of methanol in transesterification, which is the widespread biodiesel production process. The majority of this methanol is currently obtained from fossil resources, i.e. coal and natural gas. However, in contrast with methanol, biomass-based ethanol can also be used to produce biodiesels; this could allow the production line to become fully renewable. This study aimed to investigate the spray characteristics of various ethyl ester type biodiesels derived from sunflower and corn oils in comparison to methyl esters based on the same feedstocks and reference petroleum-based diesel. Spray penetration length (SPL) and spray cone angle (SCA) were experimentally evaluated in a constant volume chamber allowing optical access, under chamber pressures of 0, 5, 10 and 15 bar and injection pressures of 600 and 800 bar. Sauter mean diameter (SMD) values were estimated by using an analytical correlation. Consequently, ethyl esters performed longer SPL (2.8–20%) and narrower SCA (5.1–19%) than diesel under ambient pressures of 5 and 10 bar. Although the SMD values of ethyl esters were 48% higher than diesel on average, their macroscopic spray characteristics were very similar to those of diesel under 15 bar chamber pressure. Moreover, ethyl esters were found to be very similar to methyl esters in terms of spray characteristics. The differences in SPL, SCA and SMD values for both types of biodiesels were lower than 4%. When considering the uncertainty (± 0.84%) and repeatability (±5%) ratios, the difference between the spray characteristics of methyl and ethyl esters was not major.Article Citation - WoS: 21Citation - Scopus: 23Wearable Motion Capture System Evaluation for Biomechanical Studies for Hip Joints(ASME, 2021) Mihçin, Şenay; Çıklaçandır, Samet; Koçak, Mertcan; Tosun, AliyeHuman motion capture (MOCAP) systems are vital while determining the loads occurring at the joints. Most of the clinical MOCAP systems are very costly, requiring investment and infrastructure. Therefore, alternative technologies are in demand. In this study, a novel markerless wearable MOCAP system was assessed for its compatibility with a biomechanical modeling software. To collect evidence, experiments were designed in two stages for quantifying the range of motion (ROM) of the hip joint, in vitro and in vivo. Three constrained single-plane motions-abduction/adduction, flexion/extension, and internal/external rotation movements of the active leg-were analyzed. The data were collected from 14 healthy volunteers, using the wearable system and a medical grade optoelectronic MOCAP system simultaneously and compared against. For the in vitro study, the root-mean-square error (RMSE) for the abduction/adduction motion of the hip joint was calculated as 0.11deg/0.30deg and 0.11deg/0.09deg, respectively, for the wearable and the opto-electronic system. The in vivo Bland-Altman plots showed that the two system data are comparable. The simulation software is found compatible to run the simulations in offline mode. The wearable system could be utilized in the field of biomechanics software for running the kinetic simulations. The results demonstrated that the wearable system could be an alternative in the field of biomechanics based on the evidence collected.Article Citation - WoS: 6Citation - Scopus: 8Flexible and Expandable Robot for Tissue Therapies - Modeling and Design(IEEE, 2021) Atwya, Mohamed; Kavak, Can; Alisse, Elodie; Liu, YanQiang; Damian, Dana D.Objective: Implantable technologies should be mechanically compliant with the tissue in order to maximize tissue quality and reduce inflammation during tissue reconstruction. We introduce the development of a flexible and expandable implantable robotic (FEIR) device for the regenerative elongation of tubular tissue by applying controlled and precise tension to the target tissue while minimizing the forces produced on the surrounding tissue. Methods: We introduce a theoretical framework based on iterative beam theory static analysis for the design of an expandable robot with a flexible rack. The model takes into account the geometry and mechanics of the rack to determine a trade-off between its stiffness and capability to deliver the required tissue tension force. We empirically validate this theory on the benchtop and with biological tissue. Results: We show that FEIR can apply the required therapeutical forces on the tissue while reducing the amount of force it applies to the surrounding tissues as well as reducing self-damage. Conclusion: The study demonstrates a method to develop robots that can change size and shape to fit their dynamic environment while maintaining the precision and delicacy necessary to manipulate tissue by traction. Significance: The method is relevant to designers of implantable technologies. The robot is a precursor medical device for the treatment of Long-Gap Esophageal Atresia and Short Bowel Syndrome.Article Citation - WoS: 21Citation - Scopus: 22Daily Application of Low Magnitude Mechanical Stimulus Inhibits the Growth of Mda-Mb Breast Cancer Cells in Vitro(BioMed Central Ltd., 2014) Ölçüm, Melis; Özçivici, EnginIntroduction: Mechanical loads can regulate cell proliferation and differentiation at various stages of development and homeostasis. However, the extension of this regulatory effect of mechanical loads on cancer cells is largely unknown. Increased physical compliance is one of the key features of cancer cells, which may hamper the transmission of mechanical loads to these cells within tumor microenvironment. Here we tested whether brief daily application of an external low magnitude mechanical stimulus (LMMS), would impede the growth of MDA-MB-231 aggressive type breast cancer cells in vitro for 3 wks of growth. Methods: The signal was applied in oscillatory form at 90 Hz and 0.15 g, a regimen that would induce mechanical loads on MDA-MB-231 cells via inertial properties of cells rather than matrix deformations. Experimental cells were exposed to LMMS 15 min/day, 5 days/week in ambient conditions while control cells were sham loaded. Cell proliferation, viability, cycle, apoptosis, morphology and migration were tested via Trypan Blue dye exclusion, MTT, PI, Annexin V, Calcein-AM and phalloidin stains and scratch wound assays. Results: Compared to sham controls, daily application of LMMS reduced the number and viability of cancerous MDA-MB-231 cells significantly after first week in the culture, while non-cancerous MCF10A cells were found to be unaffected. Flow cytomety analyses suggested that the observed decrease for the cancer cells in the LMMS group was due to a cell cycle arrest rather than apoptosis. LMMS further reduced cancer cell circularity and increased cytoskeletal actin in MDA-MB-231 cells. Conclusion: Combined, results suggest that direct application of mechanical loads negatively regulate the proliferation of aggressive type cancer cells. If confirmed, this non-invasive approach may be integrated to the efforts for the prevention and/or treatment of cancer.
