Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Permanent URI for this collectionhttps://hdl.handle.net/11147/7148

Browse

Search Results

Now showing 1 - 10 of 18
  • Article
    Citation - WoS: 83
    Citation - Scopus: 93
    Airfoil Optimization for Noise Emission Problem and Aerodynamic Performance Criterion on Small Scale Wind Turbines
    (Elsevier Ltd., 2012) Göçmen, Tuhfe; Özerdem, Barış
    Noise emission is one of the major concerns in wind turbine industry and especially for small scale wind turbines, which are mostly erected to the urban areas; the concern is turning into a problem. This paper focuses on the optimization of six airfoils which are widely used on small scale wind turbines in terms of the noise emission and performance criteria and the numerical computations are performed for a typical 10 kW wind turbine. The main purpose of this optimization process is to decrease the noise emission levels while increasing the aerodynamic performance of a small scale wind turbine by adjusting the shape of the airfoil. The sources of the broadband noise emission are defined and their dominancy is investigated with respect to the operating conditions. While redesigning, together with the principals of reducing the airfoil self-noise, the aerodynamic prospects of increasing the performance have been taken into account. The codes which are based on aero-acoustic empirical models and a collection of well-known aerodynamic functions are used in this study. The results obtained from the numerical analysis of the optimization process have shown that, the considered commercial airfoils for small scale wind turbines are improved in terms of aero-acoustics and aerodynamics. The pressure sides of the baseline airfoils have been manipulated together with the trailing edge and redesigned airfoils have lower levels of noise emission and higher lift to drag ratios. © 2012 Elsevier Ltd.
  • Letter
    Citation - WoS: 2
    Citation - Scopus: 3
    A Comment on Change of Nusselt Number Sign in a Channel Flow Filled by a Fluid-Saturated Porous Medium With Constant Heat Flux Boundary Conditions
    (Springer Verlag, 2013) Uçar, Eren; Mobedi, Moghtada; Özerdem, Barış; Pop, Ioan
    The aim of this Letter is to show that, the Nusselt number sign might be changed without changing of heat transfer direction at the wall of channels, even for flows without viscous dissipation. The sign of the Nusselt number is important for deciding on heat transfer direction at a solid wall. The change of the Nusselt number signmay be interpreted as the change of the direction of the heat transfer at a wall. There are studies, such as internal heat and fluid flow in a channel with viscous dissipation (Hung and Tso 2008, 2009; Mitrovic and Maletic 2007; Mobedi et al. 2010) or with an asymmetric heat flux boundary conditions (Cekmer et al. 2011) in which the sign of the wall Nusselt number changes. Nield and Kuznetsov (2008) studied in a very interesting paper the counter flow in a channel whose boundaries are asymmetrically heated and is consisted of two porous layers with different permeability values. These authors showed that even the sign of an overall Nusselt number defined based on the average wall temperatures and heat fluxes, and the mean permeability values of the two porous layers can also be changed and it can take negative values when a strong asymmetry heat flux is imposed to the boundaries. The change of Nusselt number sign at the walls are also observed in other studies of Kuznetsov (Kuznetsov and Nield 2010; Xiong and Kuznetsov 2000).
  • Article
    Citation - WoS: 32
    Citation - Scopus: 38
    Fully Developed Forced Convection in a Parallel Plate Channel With a Centered Porous Layer
    (Springer Verlag, 2012) Çekmer, Özgür; Mobedi, Moghtada; Özerdem, Barış; Pop, Ioan
    In this study, fully developed heat and fluid flow in a parallel plate channel partially filled with porous layer is analyzed both analytically and numerically. The porous layer is located at the center of the channel and uniform heat flux is applied at the walls. The heat and fluid flow equations for clear fluid and porous regions are separately solved. Continues shear stress and heat flux conditions at the interface are used to determine the interface velocity and temperature. The velocity and temperature profiles in the channel for different values of Darcy number, thermal conductivity ratio, and porous layer thickness are plotted and discussed. The values of Nusselt number and friction factor of a fully clear fluid channel (Nu cl = 4. 12 and fRe cl = 24) are used to define heat transfer increment ratio (ε th = Nu p/Nu cl)and pressure drop increment ratio (ε p = f Re p/f Re cl) and observe the effects of an inserted porous layer on the increase of heat transfer and pressure drop. The heat transfer and pressure drop increment ratios are used to define an overall performance (ε = ε th/ε p) to evaluate overall benefits of an inserted porous layer in a parallel plate channel. The obtained results showed that for a partially porous filled channel, the value of ε is highly influenced from Darcy number, but it is not affected from thermal conductivity ratio (k r) when k r > 2. For a fully porous material filled channel, the value of ε is considerably affected from thermal conductivity ratio as the porous medium is in contact with the channel walls.
  • Article
    Citation - WoS: 25
    Citation - Scopus: 25
    Economical Assessment of Different Hvac Systems for an Operating Room: Case Study for Different Turkish Climate Regions
    (Elsevier Ltd., 2011) Özyoğurtçu, Gamze; Mobedi, Moghtada; Özerdem, Barış
    In this study, the annual energy consumptions of four different heating, ventilation and air conditioning (HVAC) systems serving to operation rooms (ORs) located at five different cities (Izmir, Antalya, Istanbul, Ankara and, Erzurum) in Turkey are analyzed. The study is performed for four different HVAC systems: (a) 100% fresh air system (System I), (b) 100% fresh air with half air volume rate at night period (System II), (c) 100% fresh air with half air volume rate at night period and heat recovery unit (System III), (d) 50% fresh air with half air volume rate at night period and with heat recovery and mixing units (System IV). Life cycle cost (LCC) for 20 years life span is calculated for the considered systems. It is found that System IV considerably reduces energy consumption and it is economically proper for the considered cities. The rate of energy consumption and LCC reductions are greater for the cities with extreme climate condition having relatively low specific humidity ratio. Using System IV instead of System I reduces OR energy consumption by 74% for the city of Erzurum which has a cold and dry climate.
  • Article
    Citation - WoS: 19
    Citation - Scopus: 23
    Fully Developed Forced Convection Heat Transfer in a Porous Channel With Asymmetric Heat Flux Boundary Conditions
    (Springer Verlag, 2011) Çekmer, Özgür; Mobedi, Moghtada; Özerdem, Barış; Pop, Ioan
    An analytical study is performed on steady, laminar, and fully developed forced convection heat transfer in a parallel plate channel with asymmetric uniform heat flux boundary conditions. The channel is filled with a saturated porous medium, and the lower and upper walls are subjected to different uniform heat fluxes. The dimensionless form of the Darcy-Brinkman momentum equation is solved to determine the dimensionless velocity profile, while the dimensionless energy equation is solved to obtain temperature profile for a hydrodynamically and thermally fully developed flow in the channel. Nusselt numbers for the lower and upper walls and an overall Nusselt number are defined. Analytical expressions for determination of the Nusselt numbers and critical heat flux ratio, at which singularities are observed for individual Nusselt numbers, are obtained. Based on the values of critical heat flux ratio and Darcy number, a diagram is provided to determine the direction of heat transfer between the lower or upper walls while the fluid is flowing in the channel.
  • Article
    Citation - WoS: 15
    Citation - Scopus: 17
    Heat Transfer and Pressure Drop Characteristics of Fin-Tube Heat Exchangers With Different Types of Vortex Generator Configurations
    (Begell House Inc., 2010) Bilir, Levent; Özerdem, Barış; Erek, Aytunç; İlken, Zafer
    A fin-and-tube heat exchanger with three different types of vortex generators is investigated in this study in order to observe the effects of these vortex generators on heat transfer and pressure drop characteristics. The individual as well as the cumulative influences of the vortex generators on the performance of a heat exchanger are examined. The numerical analyses are performed using a computational fluid dynamics (CFD) program named "Fluent". Firstly, each vortex generator type is placed at four different locations on the fin to determine its best location in terms of heat transfer and pressure drop values. After the determination of the best location on the fin for a vortex generator of each type, two different models with all three types of vortex generators are created and analyzed numerically. The investigation of the cumulative effect of three different vortex generators is the novelty of the study. The results of the study show that the use of three different vortex generators together increases heat transfer rate with a moderate increase in pressure drop value. The comparison of the present study results with an experimental and numerical study showed also a good agreement. © 2010 by Begell House, Inc.
  • Article
    Citation - WoS: 103
    Citation - Scopus: 132
    Break-Even Analysis and Size Optimization of a Pv/Wind Hybrid Energy Conversion System With Battery Storage - a Case Study
    (Elsevier Ltd., 2009) Ekren, Orhan; Yetkin Ekren, Banu; Özerdem, Barış
    This paper aims to show an optimum sizing procedure of autonomous PV/wind hybrid energy system with battery storage and a break-even analysis of this system and extension of transmission line. We use net present value (NPV) method for the comparison of autonomous hybrid energy system and extension of transmission line cases. The case study is completed for the satisfaction of the electricity consumption of global system for mobile communication base station (GSM) at Izmir Institute of Technology Campus Area, Urla, Izmir, Turkey. First, we optimize the PV/wind energy system using response surface methodology (RSM) which is a collection of statistical and mathematical methods relying on optimization of response surface with design parameters. As a result of RSM, the optimum PV area, wind turbine rotor swept area, and battery capacity are obtained as 3.95 m2, 29.4 m2, 31.92 kW h, respectively. These results led to $37,033.9 hybrid energy system cost. Second, break-even analysis is done to be able to decide the optimum distance where the hybrid energy system is more economical than the extension of the transmission line. The result shows that, if the distance between national electricity network and the GSM base station location where the hybrid energy system is assumed to be installed is at a distance more than 4817 m, the installation of hybrid energy system is more economical than the electricity network.
  • Article
    Citation - WoS: 14
    Citation - Scopus: 19
    A Numerical Simulation Study for the Human Passive Thermal System
    (Elsevier Ltd., 2008) Yıldırım, Eda Didem; Özerdem, Barış
    The objective of this study is to create a dynamic model representing a transient three-dimensional passive thermal model of the human body. The model is a multi-segmental, multi-layered representation of the human body with spatial subdivisions which simulates the heat transfer phenomena within the body and at its surface. In order to represent the mechanisms of heat transfer within the body, energy balance equations including conduction with adjacent tissue, heat storage, metabolic heat generation, and convective heat transfer due to the blood flow in the capillaries are taken into consideration for each tissue. The present model of the passive system accounts for the geometric and anatomic characteristics of the human body and considers the thermo-physical and the basal physiological properties of tissue materials. It is assumed that the body is exposed to combination of the convection, evaporation and radiation which are taken into account as boundary conditions when solving the passive thermal system equation. The model is capable of predicting human body temperature in any given environmental conditions. Finite difference solution scheme is used to find out the temperature distribution of human body. The results are compared with the experimental data of previous studies present in the literature. Consequently, the numerical results of present model show good agreement with the experimental data.
  • Article
    Citation - WoS: 18
    Citation - Scopus: 25
    Air Leakage Measurement and Analysis in Duct Systems
    (Elsevier Ltd., 2006) Aydın, Çiğdem; Özerdem, Barış
    Air ducts and related equipments are used in a large number of buildings having thermal comfort. In this study, energy loss related with air leakage is studied. The leakage measurement setup was produced according to NEN-EN standards and the evaluation of data have been conducted by using power law model. The measurements were made on 300 and 1000 mm diameter single circular ducts, 300 mm × 250 mm and 1000 mm × 500 mm flanged joint rectangular ducts, 300 and 630 mm diameter circular beaded slip joint ducts, 300 mm × 200 mm and 500 mm × 300 mm rectangular flanged and drive slip joint ducts, and an branched air distribution system having different diameters for positive internal pressures. Test results have showed that the most of air leakage is from the joints. The seam contribution to air leakage is relatively lower than the joints. Using sealing gaskets help to improve the air leakage by about 50%.
  • Article
    Citation - WoS: 11
    Citation - Scopus: 13
    Wind Speed Time Series Chacacterization Hy Hilbert Transform
    (John Wiley and Sons Inc., 2006) Alpay, Selda; Bilir, Levent; Özdemir, Serhan; Özerdem, Barış
    Predictions of wind energy potential in a given region are based on on-location observations. The time series of these observations would later be analysed and modelled either by a probability density function (pdf) such as a Weibull curve to represent the data or recently by soft computing techniques, such as neural networks (NNs). In this paper, discrete Hilbert transform has been applied to characterize the wind sample data measured on Izmir Institute of Technology campus area which is located in Urla, Izmir, Turkey, in March 2001 and 2002. By applying discrete Hilbert transform filter, the instantaneous amplitude, phase and frequency are found, and characterization of wind speed is acomplished. Authors have also tried to estimate the hourly wind data using daily sequence by Hilbert transform technique. Results are varying.